CLAMP-ON TESTER FOR AC/DC CURRENT #CL250

Clamp-on Testers For AC/DC Current

  • AC/DC current measurements with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • DC output
  • 55mm in diameter of measurable conductor
  • Mean value display
  • Sleep function
  • Data hold function
  • Approved for comformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V)

 
 

Specifications

Description ACA, DCA, ACV, DCV, OHM, Freq. °C Continuity Check
Method of detection Mean Value
Display LCD (Digital display: 3999 counts)
DC Current Range 400/2000A
DC Current Resolution 0.1A
Response Time Approx. 2 seconds
Range Switching Auto-range (on resistance range)
Manual-range (on current, voltage range)
Operating temperature and humidity 0 - 40°C, 85% RH or less (no condensation)
Influence of external magnetic field 4A or less at 400 A/m
Influence of conductor position ±(1.5% rdg + 3 dgt) or less
Safety Standard Conforms EN61010-1, EN61010-2-031, EN61010-2-032
Circuit voltage 1000 Vrms or less
Withstanding voltage 5.55 kV AC for one minute
Power Supply LR6 x 2
R6P (SUM-3) x 2
Battery Life Approx. 100 hours (continuous)
Consumed current Approx. 9 mA
Sleep Function Automatically powered down in about 10 minutes after the last switch operation
Diameter of measurable conductor 55 mm at maximum
Dimensions Approx. 105 (W) x 250 (H) x 49 (D) mm
Weight Approx. 530 g
Accessories Batteries, carrying case (93034)
Output plug (98012)
Test Lead (98011)
User's manual (IM CL250)
Peak Hold On all range
Max Hold On current / Voltage range

Selection Guide

AC Current Range 400/2000A
AC Current Resolution 0.1A
AC Current Frequency characteristics 40~1kHz
AC Current Method of detection Mean Value
AC Voltage Measurement O
DC Voltage Measurement O
Continuity Check Measurement O
Frequency Measurement -
Temperature Measurement -
Recorder output Function O
Waveform monitor output Function -
Data hold Function O
Auto hold Function -
Peak Hold Function -
Maximum value memory Function O
Mean value display Function -
Filter Function -
Range Hold Function (current range)
Auto ZERO Adjust Function O
Auto power-off Function Δ

Additional Specification

At 23°C±5°C,75%RH or less
Accuracy: ±( % rdg + dgt) = ±(% readout + value of least significant digit)
Parameter Reference Accuracy
DC current 400/2000A 1.5+2
AC current 400A/2000A(0~1000A) 1.5+2 (50/60Hz)
3.0+4 (40~500Hz)
5.0+4 (500~1kHz)
2000A (1001~2000A) 3.0+2 (50/60Hz)
DC voltage 400/1000V 1.0+2
AC voltage 400/750V 1.5+2 (50/60Hz)
1.5+4 (40~1kHz)
Resistance 400/4000Ω 1.5+2 , Beeps at below 50±35Ω (continuity check)
DC output DC400A (0~400mV) ±1.5% rdg ±3mV
DC2000A (0~200mV) ±1.5% rdg ±3mV
AC400A (0~400mV) AC2000A (0~100mV/0~1000A) ±1.5% rdg ±3mV (50/60Hz)
±3.0% rdg ±3mV (40~500Hz)
±5.0% rdg ±3mV (500~1kHz)
AC2000A (100.1~200mV/1001~2000A) ±3.0% rdg ±3mV (50/60Hz)
Name Description File Type  
Clamp-On Testers Catalog pdf icon
583 KB
Download
Clamp-On Testers Selection Guide pdf icon
17 KB
Download
99025 Users Manual pdf icon
161 KB
Download
Clamp On Tester Bulletin pdf icon
837 KB
Download
 

All Products Guide
All Products Guide
PDF (6.81 MB)
Contact info: +54 (11) 5199-0299
y-Link