In Serial Bus Analysis Which Standard is it Necessary to Use a Differential Probe?

There are three kinds of standards for which a differential probe is necessary:  FlexRay CAN UART (Some but not all UART)  It is not necessary to use a differential probe for the LIN, I2C and SPI standards. ...

item: 407  |  http://tmi.yokogawa.com/au/service-support/faqs/407/

What is the Warranty Period for the WE7000 Series?

The warranty period is 1 year for the main instrument, modules, and cards (accessories are not covered by warranty). In the unlikely event that a device should fail during the warranty period, repair will be provided fre...

item: 1137  |  http://tmi.yokogawa.com/au/service-support/faqs/1137/

How Many Characters Can be Placed in a Waveform Label on the DL850?

You can input up to 16 characters in a waveform label, but the DL850 will only display 8 characters max. ...

item: 732  |  http://tmi.yokogawa.com/au/service-support/faqs/732/

What is the DL850 Realtime File Divide Feature?

The DL850 realtime file divide feature enables you to record long waveform acquisitions (realtime) divided into blocks of smaller files. Each file block can be 2GB in file size. You can specify the number of files that t...

item: 721  |  http://tmi.yokogawa.com/au/service-support/faqs/721/

Why Can't the AQ637X Series OSA Detect or Display an External Display?

If the AQ637X series OSA is already running and you attempt to connect an external display, the OSA will not automatically detect the external display. The OSA will need to be re-booted before it can recognize and displa...

item: 174  |  http://tmi.yokogawa.com/au/service-support/faqs/174/

What is the Output Resolution of the D/A Analog Option for the WT3000?

The output resolution for the WT3000 is 16-bits. ...

item: 1229  |  http://tmi.yokogawa.com/au/service-support/faqs/1229/

What is the Type of Connector Used on the D/A Output of the WT230?

The D/A output of the WT230 uses a 24-Pin Centronics type connector. For additional informating regarding the 24-Pin Centronics Connector, please refer to the attached PDF and click on the link below. http://www.ddknet.c...

item: 948  |  http://tmi.yokogawa.com/au/service-support/faqs/948/

Xviewer Cannot Open DL850V Binary File and Displays "Remote Procedure Call Failed" Error

If the "remote procedure call failed" error appears, when attempting to open a DL850V binary WDF file in Xviewer, it can be resolved by updating and installing the latest version of Xviewer. You can download the latest v...

item: 1333  |  http://tmi.yokogawa.com/au/service-support/faqs/1333/

How do I Clear the Menu Screen and Message on the DL1540 from the PC?

The menu screen and messages are cleared when commands such as "start" and "cursor on" are issued. ...

item: 1203  |  http://tmi.yokogawa.com/au/service-support/faqs/1203/

How do I Programmatically Read Average Active Power Right Before the End of the Integration Interval While in Continuous Integration for the WT230?

You can read the average active power during continuous integration mode (just before the integral resets) for the WT230, by monitoring the status of the ITG or ITM bits of the extended event register.   Bit 1 ITG is u...

item: 982  |  http://tmi.yokogawa.com/au/service-support/faqs/982/