Is it Possible to Load Waveform Data Saved by Xviewer Onto the DL850/DL750?
Unfortunately, waveform data saved by Xviewer in the *.WVF, *.CSV, or *.FLD format cannot be loaded onto DL series instruments. ...
item: 308 | http://tmi.yokogawa.com/au/service-support/faqs/308/
Can I Replace the T/DIV Knob on the DL1540?
Yes, please visit our Contact Website and contact your local Yokogawa Representative to request a replacement for part no. A9080ZG....
item: 1210 | http://tmi.yokogawa.com/au/service-support/faqs/1210/
How do I Save History Acquisitions With the DLM2000?
With the DLM2000 series mixed signal oscilloscope, up to 20,000 previously captured waveforms can be saved into the acquisition memory. You can use the HISTORY function to search, display and save just one or all of the...
item: 1031 | http://tmi.yokogawa.com/au/service-support/faqs/1031/
Error(Code:846) Occurs When Attempting to Start Integration on the WT3000
"Error(Code:846): Attempted to start integration while measurement of peak overflow was in progress"The following error code will appear if Peak Over has occurred and you attempt to start integration. The WT3000 has two...
item: 805 | http://tmi.yokogawa.com/au/service-support/faqs/805/
Why are the Measured Values for Voltage, Current, and Power Unstable?
Check the "Sync Source" and zero cross filter (frequency filter) settings. For the WT3000, "Sync Source" setting is irrelevant if the data update rate is 250 ms, 500 ms, 1 s, or 2 s. Sync Source SettingIn principle, if t...
item: 1255 | http://tmi.yokogawa.com/au/service-support/faqs/1255/
What does the Cursor Value on the AQ7275 Measure?
The cursor value displays the level (dB) of the signal that is above the noise floor of the connected optical port. The noise floor is the dynamic range. This lets you know if you are approaching the maximum distance tha...
item: 1054 | http://tmi.yokogawa.com/au/service-support/faqs/1054/
Does the SL1000 Support Voltage Offset?
The SL1000 doesn’t support offset summing like DLM2000. The SL1000 doesn't have offset hardware; instead, the vOffset variable is used to affect the displayed value only. So, using this parameter would have no affect o...
item: 936 | http://tmi.yokogawa.com/au/service-support/faqs/936/
Can Xviewer Combine the Binary Format Data Files Saved by Different Products?
Yes, Xviewer has the capability of opening multiple files from different DL, SL, and WE series instruments into a single window display. The only requirement for viewing files from different products is that the sample ...
item: 539 | http://tmi.yokogawa.com/au/service-support/faqs/539/
What is the Update Rate of the Waveform Parameters for the DL1540?
The update rate is 1 to 2 Hz when all measurement items are specified on Trace1 through Trace4. The update rate is 5 to 6 Hz when only a few measurement items are specified on Trace1. ...
item: 1207 | http://tmi.yokogawa.com/au/service-support/faqs/1207/
Why Can't I use the Measurement Function on Data Loaded From Previous DL1540 Acquisitions?
The measurement function can be used only when data are saved in the ACQ (BIN) format. In addition, when data are saved in this format, all functions including waveform zoom can be used in the same fashion as with the ca...
item: 1181 | http://tmi.yokogawa.com/au/service-support/faqs/1181/