Why do I Need to use a Hub When Communicating With the Instrument via Ethernet?

The AC Power Input in all Yokogawa instruments is designed as a 3-pin connection (one of which is a GND pin). In some parts of the world, PCs are sold with AC power cables that are 2-pin. Often times this means the PC d...

item: 906  |  http://tmi.yokogawa.com/bx/service-support/faqs/906/

What is Hi-Resolution Mode?

High Resolution mode can be used to remove high frequency noise and increase vertical resolution. It achieves this by increasing the number of effective bits per data to 12-bits through digital and bandwidth filters. Th...

item: 1076  |  http://tmi.yokogawa.com/bx/service-support/faqs/1076/

Which Version of Excel can I use with the WE7000 Control Software?

Microsoft(R) Excel 97 and 2000 only....

item: 1162  |  http://tmi.yokogawa.com/bx/service-support/faqs/1162/

What is the UDP/IP Employed by the WE7000 Ethernet Module and Do I Need any Special Software to run the Protocol?

Within the protocol system, TCP and UDP (short for "User Datagram Protocol" which puts a priority on high-speed) both occupy the high rank of IP, but differ in use and function. Generally speaking, however, when we use t...

item: 1161  |  http://tmi.yokogawa.com/bx/service-support/faqs/1161/

Can I Perform Simultaneous Measurements With Several Modules Turned ON for the WE7000 Series?

Simultaneous measurement is possible by making use of the station's internal arming signal. The lag in start timing between each module would be 10 ms or less. (Some modules do not allow connection to the arming signal....

item: 1140  |  http://tmi.yokogawa.com/bx/service-support/faqs/1140/

Is Contact Input/Output Possible with the WE7262 32-Bit Digital I/O Module?

Contact input/output is possible using the WE7262 32-bit Digital input/output module's 707823/707824 16-bit Digital input/output terminal box. ...

item: 1150  |  http://tmi.yokogawa.com/bx/service-support/faqs/1150/

Can the WE7051 Ethernet Module and WE7052 Fast Ethernet Module Work Together?

Yes, you can use the WE7051 Ethernet module (10Base-T) and the WE7052 Fast Ethernet module (100Base-TX/10Base-T) together. ...

item: 1156  |  http://tmi.yokogawa.com/bx/service-support/faqs/1156/

For Which WE7000 Module has a Certificate of Calibration Been Issued?

The following WE7000 modules have a issued calibration certificate: 707111/HE 100 MS/s Digital Oscilloscope Module 707121/HE 10 MHz Function Generator Module 707141/HE 10 Universal Counter Module 707241/HE 10-Ch, Digi...

item: 1136  |  http://tmi.yokogawa.com/bx/service-support/faqs/1136/

Why Can't I Make Measurements With Either WE7141 Universal Counter or WE7261/WE7262 Digital I/O Module?

With either the WE7141 100 MHz universal counter module or the WE7261/WE7262 32-bit digital I/O module, if you are performing continuous measurements with more than three of the same modules you must set the sampling int...

item: 1176  |  http://tmi.yokogawa.com/bx/service-support/faqs/1176/

Is it Possible to Make Continuous Measurements on the WE7000 Series With Zero Dead Time and Send the Data to PC Using the A/D Modules?

You can perform continuous measurement using the digitizer module's Free Run mode. However, data transmission speeds are limited. Please consult your sales representative for details. They can tell you whether data trans...

item: 1143  |  http://tmi.yokogawa.com/bx/service-support/faqs/1143/