How do I Create DL1600 Timestamp Data for CSV Format Data Files?

The DL1600 will not save timestamp data into a column like some of the newer scopes (DL850 and DLM2000). There are two methods for adding timestamp data to the DL1600 listed below: WARNING: Please use caution when deali...

item: 1114  |  http://tmi.yokogawa.com/ca/service-support/faqs/1114/

When Displaying the Harmonic Content of Each Order on the WT Series Power Analyzer, What Value is Used for the Denominator?

The value depends on the model of the power analyzer. For WT1000, WT2000, WT100, and WT200, it is fixed to the fundamental wave. For power analyzers with 7 segments LED, the relative harmonic content is fixed to the fu...

item: 642  |  http://tmi.yokogawa.com/ca/service-support/faqs/642/

How do I set a Gage Factor Greater Than 2.2 for the 701271 Strain Input Module?

The Gage Factor setting for the 701271 Strain Input Module can be directly inputted within the range of 1.90 to 2.20. However, it is possible to indirectly set the Gage Factor to a larger value by setting the constant A ...

item: 569  |  http://tmi.yokogawa.com/ca/service-support/faqs/569/

Can I Upgrade the DLM2000 Firmware Using USB Flash Drive?

If your DLM2000 has firmware version 1.245 or later, then you can use a USB flash drive to upgrade the firmware of your unit.   Note:DLM2000 refers to models DLM2024, DLM2022, DLM2034, DLM2032, DLM2052, DLM2054...

item: 523  |  http://tmi.yokogawa.com/ca/service-support/faqs/523/

Can we upgrade the DLM2000 memory to /M2?

Can we upgrade the DLM2000 memory to /M2?   No – DLM2000 Memory is factory only (must be ordered at time of new purchase); there is not a mod available for this type of upgrade. ...

item: 1310  |  http://tmi.yokogawa.com/ca/service-support/faqs/1310/

What is the Maximum Visible Light Source Distance That can be Seen by the AQ7275?

The maximum visible light source distance that can be seen by the AQ7275, through a standard SM fiber, is approximately 5 km or 3.1 miles. ...

item: 518  |  http://tmi.yokogawa.com/ca/service-support/faqs/518/

How do I Read the Measurement Values From the CSV File Saved by a WT1800 Using MATLAB?

A quick and simple way of accessing the measurement data from a CSV file saved by the WT1800 is to use the MATLAB import wizard. In MATLAB, simply click on File > Import Data.... You can also use the MATLAB built-in func...

item: 1278  |  http://tmi.yokogawa.com/ca/service-support/faqs/1278/

What is the Delay Time of the External Trigger Input on the DL2700?

There is zero delay because the external trigger circuit on the DL2700 is located before the A/D converter. The timing is approximately 10 ns faster than the trigger captured on the measured waveform, since there are no ...

item: 1226  |  http://tmi.yokogawa.com/ca/service-support/faqs/1226/

Why Can't I Make Measurements With Either WE7141 Universal Counter or WE7261/WE7262 Digital I/O Module?

With either the WE7141 100 MHz universal counter module or the WE7261/WE7262 32-bit digital I/O module, if you are performing continuous measurements with more than three of the same modules you must set the sampling int...

item: 1176  |  http://tmi.yokogawa.com/ca/service-support/faqs/1176/

Can the WE7000 Main Unit be Operated on DC Power?

At present, a separate DC/AC inverter is required. In case of the WE800 measurement station (eight slots), it has a maximum power consumption of 550VA. ...

item: 1138  |  http://tmi.yokogawa.com/ca/service-support/faqs/1138/