How Can I Programatically Verify if the Calculations for Waveform Parameters are Completed?

There are two methods to programmatically determine if the calculations for waveform parameters is completed on the DL series oscilloscopes. Send the :MEAS:WAIT? command. This will ensure that no other commands are exec...

item: 1041  |  http://tmi.yokogawa.com/cl/service-support/faqs/1041/

Can I use the Store Function to Record Waveform Data on the WT1800?

THE WT1800 and WT500 STORE function can only be used to record NUMERIC data.   The WT1600 and WT3000 STORE function can be used to record both NUMERIC and WAVEFORM data. ...

item: 915  |  http://tmi.yokogawa.com/cl/service-support/faqs/915/

What are the RS232 Cable Pinouts Used by the WT & PZ Series Power Analyzers?

Please refer to the attached Excel spreadsheet for complete information regarding the RS232 cable pinouts used with by the WT & PZ Series Power Analyzers. ...

item: 481  |  http://tmi.yokogawa.com/cl/service-support/faqs/481/

How do I Retrieve Specific Items From the WT1000/WT2000 Using IEEE488.2 Commands?

Send the "MEASURE:ITEM:NORMAL:PRESET:CLEAR" command. This command turns all items for output OFF. Therefore no items will be output if you send the "MEASURE:VALUE?" command. Send the "MEASURE:ITEM:NORMAL:V:ELEMENT1 ON" ...

item: 1245  |  http://tmi.yokogawa.com/cl/service-support/faqs/1245/

What is the Warranty Period for the WE7000 Series?

The warranty period is 1 year for the main instrument, modules, and cards (accessories are not covered by warranty). In the unlikely event that a device should fail during the warranty period, repair will be provided fre...

item: 1137  |  http://tmi.yokogawa.com/cl/service-support/faqs/1137/

What is the Limit for Each Module That can be Placed in a DL850?

The number of each module that can be placed in a DL850 is limited to a maximum of: Voltage Scanner Module: 8 CAN Bus Monitoring Module: 2 (must be installed in slot 7 & 8) Logic Input Module: 8 100 MS/sec Module: 4 (mu...

item: 709  |  http://tmi.yokogawa.com/cl/service-support/faqs/709/

Can the DL1540C Load the Binary Data File of the DL1540?

No, the DL1540C cannot load the binary data file of the DL1500. The DL1540C can only load the binary data file saved by the DL1540C. The DL1540CL can load the binary data file saved by the DL1540C and DL1540CL...

item: 617  |  http://tmi.yokogawa.com/cl/service-support/faqs/617/

In Serial Bus Analysis Which Standard is it Necessary to Use a Differential Probe?

There are three kinds of standards for which a differential probe is necessary:  FlexRay CAN UART (Some but not all UART)  It is not necessary to use a differential probe for the LIN, I2C and SPI standards. ...

item: 407  |  http://tmi.yokogawa.com/cl/service-support/faqs/407/

What are the Different Power Cord Standards and Suffix Codes Supplied by Yokogawa?

Yokogawa supplies 6 different power cord standards listed below. Suffix Code Description Country -D UL/CSA standard power cord, maximum rated voltage:125 V, part no. A1006WD USA Japan -F VDE standard power c...

item: 1048  |  http://tmi.yokogawa.com/cl/service-support/faqs/1048/

Why are the Measured Values for VAR and ΣVAR Unstable?

Check the Synch Source and Frequency Filter settings When a single-phase signal being measured fluctuates around power factor of 1.Slight fluctuations in the measured values of voltage, current, and power can cause a la...

item: 1268  |  http://tmi.yokogawa.com/cl/service-support/faqs/1268/