DLM6000 MSO & DSO SERIES

Yokogawa's new DLM6000 series digital and mixed signal oscilloscopes boast fresh physical and on-screen interfaces, based on extensive market research and user feedback. It incorporates dedicated, backlit buttons for the most commonly accessed settings, and unique Yokogawa controls, like the 5-way selector button and spring loaded ‘jog shuttle' control.
The DLM6000 series oscilloscopes offer an extensive range of capabilities for waveform characterization, powerful tools for detecting glitches and anomalies, advanced signal enhancement and noise reduction technologies, and a range of options for serial bus analysis and power measurement. Select from models with four channels plus 16 or 32 bit logic inputs, and 500MHz, 1.0GHz, or 1.5GHz bandwidths.
page links
Details
section links
Features
High-Speed Acquisition and History Memory
High Acquisition Rate Unchanged Even When Displaying Logic Signals
Waveform update rate determines your probability of catching an intermittent glitch. On other mixed signal oscilloscopes, enabling the logic inputs severly impacts waveform update rate. The DLM6000 maintains waveform update rates so you can detect abnormalities and transients in your analog or logic channels. |
![]() |
| History Memory Function and High Speed Acquisition
|
![]() |
High-speed acquisition means you can even capture instantly
On most oscilloscopes, to observe and analyze abnormalities such as unpredictable noise in detail, you have to devise clever trigger settings and re-measure the event.But with the DL6000/DLM6000 there is no need to re-measure the phenomena because once the event occurs, you can use the History Memory function to recall past waveforms that were originally displayed on screen.

Example of the usefulness of observing intermittent signals: Observation of SD bus commands
SD card bus commands are sent intermittently, and the non-signal portions of these waveforms do not need to be analyzed.To be able to capture the commands that you want to observe from such signals, you can set a serial bus trigger and use the History memory to acquire up to 2000 of the waveforms that match the trigger conditions into History memory while ignoring the non-signal waveforms.
Rather than acquiring a single waveform to the entire acquisition memory, you can acquire multiple waveforms of only the needed command, and analyze them.

Search & Zoom
![]() |
Quickly extract locations and abnormalities you wish to analyze from the acquired waveform data, and zoom in anywhere on waveform details. The DL6000/DLM6000 series has enhanced Search and Zoom functions for searching for desired portions of waveform data and observing those waveforms in detail. |
Search function for extracting abnormal phenomena
The search function can search both analog and logic signals in History Memory (History Search).
Main Search Functions:
- State search (Hi/Lo setting of each channel)
- Serial pattern (I2C, SPI, CAN, general-use pattern) search
- Polygon zone search
- Waveform zone search
- Parameter search (Measured parameters, FFT, etc.)

Display two zoom areas simultaneously
Because the DL6000/DLM6000 series lets you set zoom factors independently, you can display two zoomedwaveform areas with different time axis scales at the same time.
Zoom and scroll with the zoom knob and jog shuttle
Intuitively adjust the zoom factor with the zoom knob, and the scroll with the jog shuttle. You can also scroll the zoom window automatically with the Auto Scroll function.
Automated measurement of waveform parameters
Automated measurement of waveform parameters - Automatically display waveform values
|
|
Measure a variety of parameters automatically
Simply select the check boxes of parameters you wish to measure automatically in the setting screen's parameter list.
Simultaneously measure up to 16 parameters during acquisition. Additional measured values can be obtained in the analysis screen, or via PC communication.
| You can measure waveform parameters of every cycle of a periodic waveform, and display results in lists and trend graphs. This is useful when evaluating period-by-period waveform fluctuations or loss in switching circuits. | ![]() |
Real Time Filter and High Resolution Mode
Input FiltersThe DLM6000/DL6000 can restrict filter out unwanted high frequency noise and expose only the frequency bandwidth of the signals you are working with. Every analog channel offers independent, real-time bandwidth filters.
- Analog Filters: 200MHz / 20MHz
- Real-time Digital Filters: 8MHz / 4MHz / 2MHz / 1MHz 500kHz / 250kHz / 125kHz / 62.5kHz / 32kHz/ 16kHz / 8kHz

High Resolution Mode
Digital oscilloscopes have offer excellent time resolution. However, nearly all digital oscilloscopes provide only 8-bits of vertical (voltage) resolution. With Yokogawa's High Resolution mode (real-time FIR filter), the oscilloscope will oversample and reconstruct a higher resolution signal with resolutions of up to 12 bits. Unlike averaging, High Resolution mode does not require a repetitive signal and works on single shot acquisitions.| Switching Waveform Measurement When measuring SMPS waveforms, highly precise evaluation is impossible due to the insufficient dynamic range offered by 8-bit oscilloscopes. In such cases, you can use High Resolution mode to raise the precision of the waveform as well as of any computed results. |
|
Intuitive Operation and High Performance Waveform Analysis Tool


Functions
Abundant Trigger Functions
![]() |
To easily isolate specific waveforms, the DL6000/DLM6000 offers a variety of application-oriented triggers, from simple edge triggers to pulse width, multi-criteria combination and time difference triggers. ![]() |
Action On Trigger Function
When your test involves waiting for intermittent phenomena, you can use the Action On trigger function to automatically save waveform data to file when trigger conditions are met. You can also send e-mail notifications on every trigger. Even for phenomena that occur only once per day or less, you can be sure that a record of the data, including the date and time, will be kept.
Logic signal measurement and analysis
Observing up to 32-bit logic signals together with analog signals
Observing many signals simultaneously and checking their correlations and timing is an effective means of verifying increasingly complex embedded systems.
With the DLM6000 series, you can measure up to 32-bit logic signals and 4 channels of analog waveforms simultaneously, and investigate hidden data in waveforms using bus analysis and computation functions.

Grouping logic signals to make them easy to read and understand
As many as 5 groups of logic signals can be defined. You can enter display settings for each group, and specify which bit in each group is the LSB or MSB
regardless of the bit arrangement of the logic probe.
This means that even if pin assignments or signal arrangements change, you only need to change settings rather than to repeat the probing of the circuit.

Bus and State displays make logic signals easy to read and analyze
The DL6000/DLM6000 is not limited to displaying logic signals as waveforms. It can also show logic signals assigned to groups in a Bus display, or specified
clock signals in a State display.
Therefore, parallel output values of an address bus or A/D converter can be read directly. Functions like these make analysis of logic signals easy, so that operating checks of the device under test can be performed more quickly and accurately.
Virtual D/A Computation function displays to 32-bit logic signals as analog waveforms
The DL6000/DLM6000 includes a Virtual D/A Computation function, in which address bus signals or logic signals from data converter I/O can be converted to analog waveforms and displayed. You can display logic signals output from an A/D converter, and by comparing them with the original analog waveforms prior to conversion, you can investigate the general dynamic characteristics of the A/D conversion. Displaying the address bus signal as a waveform is also useful for identifying instances of abnormal memory access. D/A converted waveforms can undergo FFT analysis or have additional digital filtering computations applied to them. |
![]() |
There are two different types of logic probe that can be used with the DLM6000, depending on the application.
- 250 MHz logic probe (model 701989, Input Impedance: 100 kΩ) The model 701989 is a 250 MHz logic probe with a tip shape designed for probing circuit boards. In addition to probing with the pincher tip, the tips can be stacked in the included holder, making it easy to connect to and disconnect from a 2.54 mm pitch box connector.
- High impedance logic probe (model 701988, Input Impedance: 1MΩ, Max. toggle speed 100MHz) The model 701988 is a 100 MHz general-purpose logic probe with an impedance of 1 MΩ. Its high impedance gives it characteristics that make it difficult to influence the behavior of the target. Aside from pincher tip probing, the head with the tip removed can also be connected to a 2.54 mm pitch diameter connector.
Options
Serial bus analysis function (option)
You can add on I2C, SPI, CAN, LIN, and other serial bus-specific trigger and analysis functions to your DL6000/DLM6000 series instrument. With these functions, you can trigger on specific serial bus parameters, and display the waveforms along with protocol analysis indicating the decoded serial bus information.
Moreover, the DL6000/DLM6000 series also comes with a "Serial Bus Auto-Setup" function to eliminate the tedious task of entering settings when starting the analysis.
Auto Setup Function for Serial Bus Analysis

| Display signal waveforms, protocol information, and decode information in real time The DL6000/DLM6000's serial bus analysis function simultaneously displays these three pieces of information on screen in real time. You can link the protocol information with the waveform information, select data in the protocol list, and automatically display the corresponding part of the analog waveform. Check the protocol list to see whether transferred information is correct. If not, you can determine whether there were any electrical problems at the waveform level. In operational analysis of systems that include serial busses, this can be very useful for sorting out hardware from software problems.
|
|
| Analyzing two busses at once Both analog and logic inputs can be used for serial bus analysis. Also, two different serial busses can be analyzed at the same time. For example, you can analyze a CAN and LIN bus simultaneously, or use an MSO to analyze two SPI busses at once. |
|
| Example: Behavioral analysis of an I2C control motor You can trigger on specific data sent to a motor controller on an I2C bus and capture the waveform. Then, you can observe and analyze the content and timing of the data, plus the behavior of the activated motor. Together with that, you can use an MSO to observe control circuit logic signals, enabling you to evaluate the overall system. ![]() |
Computation Functions
Digital filters, integrals, edge, rotary count, logic signal DA conversion computation, and FFT computation functions come standard. As these computations are hardware-based, results appear on screen quickly. Even computations that traditionally needed to be sent to a separate PC for processing can now be executed at high speed on the oscilloscope, thus greatly reducing the time and effort involved in computing and analyzing waveform data.
|
|
Digital Filter Computations Digital filters, integrals, edge, rotary count, logic signal DA conversion computation, and FFT computation functions come standard. As these computations are hardware-based, results appear on screen quickly. Even computations that traditionally needed to be sent to a separate PC for processing can now be executed at high speed on the oscilloscope, thus greatly reducing the time and effort involved in computing and analyzing waveform data. |
|
|
FFT Computation You can perform FFT computation for analog signal waveforms or DA computation waveforms. This includes not only signal spectra, but also coherent and transfer functions. |
|
|
User defined MATH (option) By combining basic math, trigonometric functions, differentials, digital filters,waveform parameters, and other values, you can define and execute equations and display the results along with the observed waveform |
Power Supply Analysis Function (optional)
By using combinations of differential and current probes, you can evaluate switching loss or analyze safe operating area (SOA) in power supply waveforms. Through statistical computation you can also measure multiple switching waveforms and display loss on a per-week basis in lists and trends, or display statistics on aggregate loss of up to 2000 switching waveforms stored in History Memory. If precise calculations are required, a correction function and High Resolution mode are available.![]() |
Cycle-by-cycle switching loss statistics and trend display It can be extremely useful to check for fluctuations in switching frequency or voltage modulated by the commercial power input voltage on screen, at the same time as the waveform of that input voltage. Fluctuations in cycle-by-cycle loss, peak current, and other phenomena can be checked in lists and trend graphs thereby allowing you to identify excessive changes from power-ON to stable operation. |
![]() Waveform parameter measurement function for power supply analysis |
Harmonic Analysis of Power Supply Current Based on EN61000-3-2 (IEC61000-3-2)
Bar graphs and lists of harmonics can be displayed together with the appropriate limits for the device under test as defined by the IEC standard (supports device classes A-D). Any measured value which exceeds the limit is highlighted.

Connectivity
Diverse Connectivity - Remote Control, Data Transfer, and Data Saving


规格
| 姓名 | 描述 | 文件类型 | |
|---|---|---|---|
| BU DLM6000-00E | DLM6000/DL6000 Series | 3.37 MB |
下载 |
应用程序注释
| 姓名 | 描述 | |
|---|---|---|
| Switched Mode Power Supply (SMPS) Analysis for Energy-Efficient Inverters, Rectifiers, Voltage Converters, and Phase Converters |
Whether your design involves an inverter, rectifier, DC to DC converter, or phase converter, switched mode power supply (SMPS )analysis and design efficiency is critical. This application handbook includes techniques for observing SMPS circuit internal waveforms, monitoring operating status, measuring efficiencies, and confirming the safety or loss in the devices used. |
了解更多 |
软件
| 姓名 | 描述 | |
|---|---|---|
| Communication Sample Programs | The following programs are DL series communication sample programs written in Visual Basic (VB) and Visual C++ (VC++)'s project format. Please refer to the User's Manual(IM 701990-01E) for detailed information, which can be extracted from "dlsample101.zip" file. | y-Link |
| DL-Term | DL-Term is a command line tool for the DL series library. Please use this software as a development tool for writing communication programs using the DL series library. | y-Link |
| LabView Driver | LabVIEW drivers for DLM6000/ DL6000 /SB5000/ DL9000DSO/ DL9000MSO Series |
y-Link |
| Mask Pattern Editor | This software program is used to create mask patterns that are used on the DLM2000/ DL9000 series and SB5000. The mask pattern created using this program can be loaded into the DLM2000/DL9000/SB5000 via a PC card or USB memory and used for mask tests, GO/NO-GO judgments, and history search. | y-Link |
| MATLAB Control Tool Kit (learn more) | This MATLAB tool kit enables DL series oscilloscopes to easily interface with MATLAB. The software can be used to control supported DL series instruments from MATLAB or to transfer data from DL series instruments to MATLAB via GP-IB, USB or Ethernet. | 了解更多 |
| Symbol Editor | Create and Edit Logic Symbol Files for the SB5000, DL9700, and DL9500 Series You can create logic symbol definition files that can be used on the SB5000, DL9700, and DL9500 series. Created files can be saved for use on the SB5000, DL9700, and DL9500 series. Saved files can be loaded and edited. |
y-Link |
| TMCTL - 2.150a | TMCTL - Version 2.150a |
y-Link |
| USB Driver | The USB driver is needed when required by the software. | y-Link |
| X-Viewer 701992 (learn more) | Xviewer, an offline waveform viewing and analysis package. It can also transfer files from and remote control some Yokogawa instruments. | 了解更多 |
| XWirepuller | Xwirepuller enables the DLM2000 series, DL9000 series including MSO models and SB5000 to be controlled from your PC via the Ethernet, USB, or GP-IB interface. |
y-Link |
| Xwirepuller-1.31 (learn more) | Xwirepuller enables the DLM2000 series, DL9000 series including MSO models and SB5000 to be controlled from your PC via the Ethernet, USB, or GP-IB interface. |
了解更多 |
附件
701912/13/14 Active Probe
Active Probe
701919 Probe Stand
Using a probe stand with a flexible arm and heavy base to hold and stabilize probes can simplify circuit board testing.
701971 DC power cord
For the DC power supply model (/DC). Allgator clip type.
701988 (PBL100) Logic Probe
701988 (PBL100) Logic Probe
701989 (PBL250) Logic Probe
Logic Probe (PBL250)
B9850NX DL printer paper (except for DL750)
Quality paper for the DL1600, DL1700E, DL7400 series.
B9988AE Printer paper for the DL750
Quality paper for the DL750, DL9040/9140/9240 and DLM2000




















