What is the Step Response of the 701280 Frequency Input Module for a Sine Wave Filtered with an IIR LP Filter?

For the 701280 Frequency Input Module with a 4th order IIR 6Hz lowpass filter, a 60Hz sine wave (FM modulated with a square wave) was measured with deviations of ± 3Hz. Please download and view the attached image for a ...

item: 986  |  http://tmi.yokogawa.com/ea/service-support/faqs/986/

What is the Type of Connector Used on the D/A Output of the WT230?

The D/A output of the WT230 uses a 24-Pin Centronics type connector. For additional informating regarding the 24-Pin Centronics Connector, please refer to the attached PDF and click on the link below. http://www.ddknet.c...

item: 948  |  http://tmi.yokogawa.com/ea/service-support/faqs/948/

What is the Maximum Visible Light Source Distance That can be Seen by the AQ7275?

The maximum visible light source distance that can be seen by the AQ7275, through a standard SM fiber, is approximately 5 km or 3.1 miles. ...

item: 518  |  http://tmi.yokogawa.com/ea/service-support/faqs/518/

Can the Waveform Data Saved in .WVF Format on the DL1540 be Loaded Onto the DL1540C/DL1540CL?

It is currently not possible to load .WVF waveform data saved by a DL1540 onto the DL1540C/DL1540CL or vice versa. This is because the internal circuit is not common between the two models. It is however, possible to loa...

item: 1187  |  http://tmi.yokogawa.com/ea/service-support/faqs/1187/

What is the Measurement Data Format?

You can select whether to save files in binary (WVF format) or ASCII (CSV format). WVF is Yokogawa's proprietary format. CSV format can be read by popular spreadsheet programs. ...

item: 1165  |  http://tmi.yokogawa.com/ea/service-support/faqs/1165/

Can Multiple GS Units be Connected in Series/Parallel to Boost the Output Voltage/Current?

It is possible to connect multiple GS units in series/parallel connections to boost the maximum voltage/current, provded the values are within the range of maximum voltage/current of those limiters. To amplify the output...

item: 597  |  http://tmi.yokogawa.com/ea/service-support/faqs/597/

What are the Minimum Requirements for Linking Multiple SL1000 Units in Synchronization Mode?

The SL1000 is capable of linking up to 8 units, up to 128ch max, in synchronized mode using our SL1000 Acquisition Software. Using a common LINK file, data from all units can be processed and analyzed, as one, at the sa...

item: 306  |  http://tmi.yokogawa.com/ea/service-support/faqs/306/

Error:Code 915 Appears When Attempting to Print With the DL1540

Error:Code 915 is the error message "Can't detect listener." This error occurs when the hard copy destination is not set to the "printer," but to "plotter" without connecting external devices....

item: 1206  |  http://tmi.yokogawa.com/ea/service-support/faqs/1206/

How do I Clear the Menu Screen and Message on the DL1540 from the PC?

The menu screen and messages are cleared when commands such as "start" and "cursor on" are issued. ...

item: 1203  |  http://tmi.yokogawa.com/ea/service-support/faqs/1203/

Why Can't I Make Measurements With Either WE7141 Universal Counter or WE7261/WE7262 Digital I/O Module?

With either the WE7141 100 MHz universal counter module or the WE7261/WE7262 32-bit digital I/O module, if you are performing continuous measurements with more than three of the same modules you must set the sampling int...

item: 1176  |  http://tmi.yokogawa.com/ea/service-support/faqs/1176/


Webinar
How does the new WT300 provide reliable power measurements for your application?
View the webinar recording here.


Contact:
Yokogawa Europe BV

Tel.: +31 (0) 88 464 1429
Fax: +31 (0) 88 464 1107
tmi@nl.yokogawa.com




Buzz e-newsletter
y-Link