DELTA COMPUTATION FUNCTION (/DT OPTION)

It is possible to obtain the differential voltage, line voltage, phase voltage, etc. by obtaining the sums and differences of instantaneous measurement values of voltage and current in each element.

Delta Image

  • Differential voltage/current: Differential voltage and current between two elements are computed in the three-phase three-wire system.

  • Line voltage/phase current: Line voltage and phase current that are not measured are computed in the three-phase three-wire system (Figure 1).
  • Star-delta conversion: Line voltage is computed from the phase voltage using the three-phase four-wire system data.
  • Delta-star conversion: Phase voltage is computed from the line voltage in the three-phase three-wire system (3V3A system)
    (Figure 2).
DeltaBu1
Figure 1. Line voltage/phase current
  DeltaBu2
Figure 2. Delta-star conversion