What is the Sanitation Procedure for Yokogawa Oscilloscopes?

The sanitation procedure for various Yokogawa oscilloscopes have been documented below. Please download the document or pdf that refers to your Yokogawa oscilloscope....

item: 28  |  http://tmi.yokogawa.com/fr/service-support/faqs/28/

Does HDMI use I2C?

Yes, the HDMI pinout carries the I2C on pins 15 and 16 of the HDMI connector cable. The HDCP (content protecting encryption keys) signal is carried on pins 15 and 16. ...

item: 44  |  http://tmi.yokogawa.com/fr/service-support/faqs/44/

Is the Linear Averaging Function Supported by the DL1500 Series?

The averaging function supported by the DL1500 Series is exponential averaging. The models that support linear averaging (simple averaging) are the DL4000 Series, DL2700, and DL708. ...

item: 1194  |  http://tmi.yokogawa.com/fr/service-support/faqs/1194/

What is the Recommended Sampling Rate for CAN Bus or I2C Analysis on the DL Series Instruments?

In general, the recommended sampling rate for CAN bus or I2C analysis is 10x the bit-rate. If the waveform is not noisy, the sampling rate can be set to around 4-5x the bit-rate. ...

item: 679  |  http://tmi.yokogawa.com/fr/service-support/faqs/679/

Why Does the Pulse Width of the NO-GO Output for the DL1540 Occasionally Decrease to 12 ms and What Causes This Change?

The NO-GO output is controlled by software. Thus, there may be fluctuations in the processing time depending on the sensing conditions. Since the signal remains low until the next determination can be accepted, this mean...

item: 1211  |  http://tmi.yokogawa.com/fr/service-support/faqs/1211/

What is the Service Procedure for Verifying Time Axis Accuracy?

The Time Axis Accuracy is the accuracy of the A/D clock. It is not possible to directly measure the A/D clock and the A/D clock is not output from the DL850/SL1400. To verify the accuracy of the A/D clock, you will nee...

item: 1288  |  http://tmi.yokogawa.com/fr/service-support/faqs/1288/

How Long Does it Take to Transfer Screen Images From the DL1540 to the PC via GPIB?

The transfer could take up to 10 seconds. Normally it is 6 or 7 seconds, however this will vary depending on the performance of the PC and the GP-IB board. On the DL1540C, this may take longer than 10 s, because the scre...

item: 1205  |  http://tmi.yokogawa.com/fr/service-support/faqs/1205/

Can Data be Saved in BMP Format to the Floppy Disk for DL1540 Models Without the Built-in Printer?

Yes, screen image data can be saved in BMP and other formats even if the built-in printer is not installed. ...

item: 1184  |  http://tmi.yokogawa.com/fr/service-support/faqs/1184/

Is Color Supported When Saving or Transferring Screen Image Data on the Dl1540C/CL?

Yes, you can select color or monochrome when saving or transferring the screen image data. ...

item: 1188  |  http://tmi.yokogawa.com/fr/service-support/faqs/1188/

What is the SCSI Connector Type That Comes With the /C8 Option on the DL1540C/CL?

The SCSI connector type is half-pitch 50-pin (pin type). ...

item: 1212  |  http://tmi.yokogawa.com/fr/service-support/faqs/1212/