DATA LOGGING SOFTWARE GA10

The Data Logging Software GA10 completes Yokogawa’s data acquisition system by pulling data from Yokogawa recorder, data acquisition and controller products. Data can also be acquired from devices that support Modbus communication.

 
 

Saves time and effort by centralizing monitoring and recording tasks on a PC!!

Key Features:

  • Connectivity with many devices 
    Broad support for recorders, data loggers, temperature controllers, signal conditioners, power monitors, and power meters. Even acquires data from Modbus devices.
  • Simple settings 
    Simply select a device to connect to and start monitoring (Simple setting mode)
  • High reliability
    • Auto reconnection when communications are lost, protection of data files up to the moment of power failure
    • Data supplementing function (Backfill function)
    • Server OS support
  • Easy-to-read screen
    • Wide variety of display screens
    • Real time monitoring
  • Variety of functions
    • Alarm monitoring
    • Send via e-mail
    • Advanced viewer
    • Standard support for multilogging
    • 2 time modes
    • User privilege settings
    • Add monitoring PCs (client)
    • Release 3.0 now includes the ability to connect directly to a WT 3000/3000E Power Analyzer as well as generate custom graphics

Easy-to-read screen

Easy-to-read screen

  • Wide variety of display screens
    (1) Trend display (2) Digital display (3) Bar graph display (4) Meter display (5) Alarm monitoring/Log
  • Real time monitoring

Connectivity with many devices

Broad support for recorders, data loggers, temperature controllers, signal conditioners, power monitors, and power meters. Even acquires data from Modbus devices.

Connectivity with many devices

Please see the table below for compatible models.

Compatible Models

  Products to be connected
Recorder GX10, GX20, GP10, GP20
DX1000, DX1000N, DX2000, DX1000T, DX2000T, FX1000
MV1000, MV2000
CX1000, CX2000
µR10000, µR20000
Data Logger DA100, DR130, DR230, DR240
MX100, MW100
Temperature Controller UT75A, UT52A, UT55A, UT35A, UT32A, UP55A, UP35A, UM33A (Connected as Modbus instruments)
Power Monitor PR300 (Connected as Modbus instruments)
Signal Conditioner VJU7, VJS7, VJA7, VJH7, VJP8, VJQ7, VJQ8, VJX7, MVHK, MVRK, MVTK(Connected as Modbus instruments)
Power Meter Support planned for the following*: WT300, WT500, WT1800
Modbus device Instruments supporting Modbus communication
Software  
*Free connection software available

Simple settings

Simply select a device to connect to, and start monitoring (Simple setting mode)

Simple settings

High reliability

Auto reconnection when communications are lost, protection of data files up to the moment of power failure
Data supplementing function (Backfill function)
*Only available when the instrument's time is used for the timestamp with GX/GP/DX/MV

High reliability

Variety of functions

  • Alarm monitoring
    Alarm sound (beep), Alarm ACK
  • Send via e-mail
    • Send e-mail based on various acquisition statuses
    • Attach instantaneous values or alarm information
    • SMTP Authentication/POP before SMTP
  • Advanced viewer
    • Play back screen for recorded data
    • Print out trend and numeric values
    • Calculate statistics within specified range
    • Search for memos (marks) and alarms
  • Standard support for multilogging
    Enables acqusition of multiple data at different timing
  • 2 time mode
    • You can select PC time or instrument time for time stamps
    • Maintains consistency with instrument main unit files
  • User privilege settings
    Set 4 privilege levels: Owner, Manager, Operator, or Monitor
  • Add monitoring PCs (client)
    Monitor and share data on multiple PCs (option)

 

Data monitoring in manufacturing sites

Monitor factory data from the office.
You can also monitor on multiple PCs.

Data monitoring in manufacturing sites

Recording data from multiple equipment

Saves testing/manufacturing equipment data on a PC.
You can even record individual equipment at separate times.

Recording data from multiple equipments
OS Windows XP, Windows Vista, Windows 7, Windows 8, Windows Server 2008 R2, Windows Server 2012
CPU Pentium 4, 3.2 GHz or faster
Main memory 2 GB or more
Hard disk 200 MB or more of free space
Display A resolution of 1024 x 768 or higher, 65,536 colors (16-bit, high color) or more
Communication port RS-232 or Ethernet ports supporting the OS. 
Use a converter (ML2 recommended) for RS-422/485 communication.

Basic software

Model Suffix Code Description
GA10   Data Logging Software Basic License
Number of channels -01 100 ch
-02 200 ch
-05 500 ch
-10 1000 ch
-20  

For adding channels

Model Suffix Code Description
GA10UP   Channels upgrade license for GA10
Upgrade -01 100 ch ⇒ 200 ch, 200 ch ⇒ 500 ch,
500 ch ⇒ 1000 ch, 1000 ch ⇒ 2000 ch
-02 100 ch ⇒ 500 ch, 200 ch ⇒ 1000 ch,
500 ch ⇒ 2000 ch
-03 100 ch ⇒ 1000 ch, 200 ch ⇒ 2000 ch
-04 1000 ch

For increasing the number of monitoring PCs (clients)

Model Suffix Code Description
GA10CL   Client license for GA10
Number of licenses -01 1 license
-05 5 licenses
-10 5 licenses
-50 50 licenses

Configuation example

Configuration Example
Name Description File Type  
Model GA10/GA10CL/GA10UP Data Logging Software User's Manual External Link Download
Data Logging Software GA10 Brochure External Link Download
Boiler Data Logging Software Brochure External Link Download
Data Logging Software GA10 General Specification Sheet External Link Download
GA10 Data Logging Software Product Introduction Guide Technical Information External Link Download
GA10 Data Logging Software Setup Guide Technical Information External Link Download
Modbus Device Definition File Creating Tool for GA10 Data Logging Software User's Manual User Manual External Link Download
Before Using GateWT for GA10 User Manual External Link Download
WX1 GateWT User Manual External Link Download
GateWT Software for GA10 Software External Link Download
GA10 and Associated Products Follow the Download Link for Available Related Software External Link Download
 

All Products Guide
All Products Guide
PDF (26.47 MB)
Contact info: (62)-21-799 0102
y-Link