HIGH RESOLUTION F/V CONVERTER, PAPER FEED SYYSTEM (PRINTER ETC.), AND TRANSIENT RESPONSE
TA320 as High Resolution f/v converter
| Item | TA320 Advantage | |
| Paper feed system (printer) | Time variation | Like using a f/v converter |
Paper feed system (printer etc.) /Transient Response
Set up

Printing quality is influenced by paper feed accuracy in printer or copy machines.
The TA320 can evaluate the paper feed accuracy with very high resolution by measuring the encoder pulse of the paper feed system.
Although the TA320 can not measure frequency, it can measure Period, Pulse width, Duty, Phase and Time interval.
TA320 Setting
- Function : Period
- Display : Time variation
Example

In the Time variation display, x-axis represents the time stamp, and y-axis represents the period which means paper feed speed in this case, so paper feed speed is monitored like f/v converter output.
Oscilloscopes
World-class digital oscilloscopes from Yokogawa: The digital oscilloscopes have high-speed sampling and a wide range of bandwidths that can be utilized for design and development of electronic devices. The ScopeCorders have the advantages of both a digital oscilloscope and a multi-channel data recorder.