What is the DL850 Realtime File Divide Feature?

The DL850 realtime file divide feature enables you to record long waveform acquisitions (realtime) divided into blocks of smaller files. Each file block can be 2GB in file size. You can specify the number of files that t...

item: 721  |  http://tmi.yokogawa.com/it/service-support/faqs/721/

How do I Save History Acquisitions With the DLM2000?

With the DLM2000 series mixed signal oscilloscope, up to 20,000 previously captured waveforms can be saved into the acquisition memory. You can use the HISTORY function to search, display and save just one or all of the...

item: 1031  |  http://tmi.yokogawa.com/it/service-support/faqs/1031/

How do I Programmatically Read Average Active Power Right Before the End of the Integration Interval While in Continuous Integration for the WT230?

You can read the average active power during continuous integration mode (just before the integral resets) for the WT230, by monitoring the status of the ITG or ITM bits of the extended event register.   Bit 1 ITG is u...

item: 982  |  http://tmi.yokogawa.com/it/service-support/faqs/982/

Why are the Measured Values for Voltage, Current, and Power Unstable?

Check the "Sync Source" and zero cross filter (frequency filter) settings. For the WT3000, "Sync Source" setting is irrelevant if the data update rate is 250 ms, 500 ms, 1 s, or 2 s. Sync Source SettingIn principle, if t...

item: 1255  |  http://tmi.yokogawa.com/it/service-support/faqs/1255/

Can I Replace the T/DIV Knob on the DL1540?

Yes, please visit our Contact Website and contact your local Yokogawa Representative to request a replacement for part no. A9080ZG....

item: 1210  |  http://tmi.yokogawa.com/it/service-support/faqs/1210/

Why Can't I use the Measurement Function on Data Loaded From Previous DL1540 Acquisitions?

The measurement function can be used only when data are saved in the ACQ (BIN) format. In addition, when data are saved in this format, all functions including waveform zoom can be used in the same fashion as with the ca...

item: 1181  |  http://tmi.yokogawa.com/it/service-support/faqs/1181/

What does the Cursor Value on the AQ7275 Measure?

The cursor value displays the level (dB) of the signal that is above the noise floor of the connected optical port. The noise floor is the dynamic range. This lets you know if you are approaching the maximum distance tha...

item: 1054  |  http://tmi.yokogawa.com/it/service-support/faqs/1054/

Can I Transfer Data Files From the SL1000 While Recording is in Progress?

The SL1000 is capable of transferring previous data sets/files while streaming is still in progress through the File Divide feature. When the SL1000 starts recording, it opens a new file and starts logging data. If the ...

item: 171  |  http://tmi.yokogawa.com/it/service-support/faqs/171/

Does the SL1000 Support Voltage Offset?

The SL1000 doesn’t support offset summing like DLM2000.  The SL1000 doesn't have offset hardware; instead, the vOffset variable is used to affect the displayed value only.  So, using this parameter would have no affect o...

item: 936  |  http://tmi.yokogawa.com/it/service-support/faqs/936/

Can Xviewer Combine the Binary Format Data Files Saved by Different Products?

Yes, Xviewer has the capability of opening multiple files from different DL, SL, and WE series instruments into a single window display. The only requirement for viewing files from different products is that the sample ...

item: 539  |  http://tmi.yokogawa.com/it/service-support/faqs/539/