What is the DL850 GigaZoom II?

GigaZoom II is a display processor implemented via architectural technology on an FPGA. ...

item: 722  |  http://tmi.yokogawa.com/kr/service-support/faqs/722/

If There is a Temperature Coefficient Listed in the Specifications, When is the Coefficient to be Applied?

If there is a temperature coefficient listed in the specifications of the instrument's user manual, that coefficient is to be applied in the following conditions: The unit is calibrated within the Standard Operating Co...

item: 1297  |  http://tmi.yokogawa.com/kr/service-support/faqs/1297/

How do I Setup the DL850 Wave Window Trigger?

Please see the attached "DL850 Wave Window FAQ.zip" for detailed instructions and setup feature explanations. There is also a wave window FAQ discussion included in the zip file. ...

item: 1277  |  http://tmi.yokogawa.com/kr/service-support/faqs/1277/

What are the Different Types of Memory on the SL1000?

The SL1000 has the following types of memory: Internal Hard Drive: 40 GB Non-Volatile SRAM Waveform Acquisition Memory: 128 MW or 256 MB Volatile RAM Setup File Data Storage: 1 MB Volatile SRAM(Battery-Backup) ...

item: 937  |  http://tmi.yokogawa.com/kr/service-support/faqs/937/

How Do the Line & Frequency Filters Affect Signals Close to the Filter Cutoff Frequency?

The circuit design for the line filters used on the WT & PZ series instruments are similar to Butterworth filters but have been redesigned. We redesigned the original filtering characteristic to obtain a sharper rolloff ...

item: 912  |  http://tmi.yokogawa.com/kr/service-support/faqs/912/

Can a Large Data File be Saved Onto Multiple Floppy Disks With the DL1540L?

Yes, if all the data cannot fit onto one disk, a message will appear prompting you to enter the next floppy disk. Simply follow the instructions to save the data to multiple floppy disks. The same procedure also applies ...

item: 1183  |  http://tmi.yokogawa.com/kr/service-support/faqs/1183/

What is the Measurement Data Format?

You can select whether to save files in binary (WVF format) or ASCII (CSV format). WVF is Yokogawa's proprietary format. CSV format can be read by popular spreadsheet programs. ...

item: 1165  |  http://tmi.yokogawa.com/kr/service-support/faqs/1165/

Why Doesn't the Theoretical Power Value Match the Measured Power Value?

Check for differences in the specifications or features of the instruments. For values that do not match when inputting a 50/60 sine wave Check whether the value is within the specifications (error) of each power meter...

item: 1258  |  http://tmi.yokogawa.com/kr/service-support/faqs/1258/

Are the Standard Operating Conditions for the DL850 Equivalent to the Compensated Temperature Range?

No, the Standard Operating Conditions are not equivalent to the compensated temperature range. The unit's accuracy specifications are valid when operated within the Standard Operating Conditions and when the temperature ...

item: 1296  |  http://tmi.yokogawa.com/kr/service-support/faqs/1296/

How do I Retrieve Specific Items From the WT1000/WT2000 Using IEEE488.2 Commands?

Send the "MEASURE:ITEM:NORMAL:PRESET:CLEAR" command. This command turns all items for output OFF. Therefore no items will be output if you send the "MEASURE:VALUE?" command. Send the "MEASURE:ITEM:NORMAL:V:ELEMENT1 ON" ...

item: 1245  |  http://tmi.yokogawa.com/kr/service-support/faqs/1245/