Why Won't Xviewer Open the CSV ASCII File Created by the ScopeCorder?

To open the CSV ASCII file saved by your ScopeCorder: Start Xviewer Open a New Viewer Window Drag and drop your CSV file into the empty viewer window Additional Note:ScopeCorder refers to the DL750/DL750P, DL850/DL850V,...

item: 56  |  http://tmi.yokogawa.com/mx/service-support/faqs/56/

Xviewer Cannot Open DL850V Binary File and Displays "Remote Procedure Call Failed" Error

If the "remote procedure call failed" error appears, when attempting to open a DL850V binary WDF file in Xviewer, it can be resolved by updating and installing the latest version of Xviewer. You can download the latest v...

item: 1333  |  http://tmi.yokogawa.com/mx/service-support/faqs/1333/

INTEG1 vs INTEG2 - as demonstrated on DL850 G3

INTEG1 vs INTEG2 - as demonstrated on DL850 G3   Examples of two different ways to INTEGRATE on the DL850/G3 DSP.   One attachment. ...

item: 1311  |  http://tmi.yokogawa.com/mx/service-support/faqs/1311/

How Many Characters Can be Placed in a Waveform Label on the DL850?

You can input up to 16 characters in a waveform label, but the DL850 will only display 8 characters max. ...

item: 732  |  http://tmi.yokogawa.com/mx/service-support/faqs/732/

How do I Retrieve Data From the Instrument Only When it is Updated Using IEEE488.2 Commands?

You can use the "STATUS:ESSR?" command to access the extended event register and determine whether the data was updated. You can judge the data update status by referencing bit 0 (UPD) of this register. However to do so,...

item: 1249  |  http://tmi.yokogawa.com/mx/service-support/faqs/1249/

What is the Update Rate of the Waveform Parameters for the DL1540?

The update rate is 1 to 2 Hz when all measurement items are specified on Trace1 through Trace4. The update rate is 5 to 6 Hz when only a few measurement items are specified on Trace1. ...

item: 1207  |  http://tmi.yokogawa.com/mx/service-support/faqs/1207/

Why Won't the Numerical Value I Enter for Record Length Save for the WE7275/WE7271/WE7272 Digitizer Module?

The minimum record length which can be input is limited such that "record length x sampling interval" must be 5 milliseconds or more. When you set the record length to a value smaller than this it automatically changes t...

item: 1173  |  http://tmi.yokogawa.com/mx/service-support/faqs/1173/

How Can I Programatically Verify if the Calculations for Waveform Parameters are Completed?

There are two methods to programmatically determine if the calculations for waveform parameters is completed on the DL series oscilloscopes. Send the :MEAS:WAIT? command. This will ensure that no other commands are exec...

item: 1041  |  http://tmi.yokogawa.com/mx/service-support/faqs/1041/

How do I Save History Acquisitions With the DLM2000?

With the DLM2000 series mixed signal oscilloscope, up to 20,000 previously captured waveforms can be saved into the acquisition memory. You can use the HISTORY function to search, display and save just one or all of the...

item: 1031  |  http://tmi.yokogawa.com/mx/service-support/faqs/1031/

Can the DL1540C Load the Binary Data File of the DL1540?

No, the DL1540C cannot load the binary data file of the DL1500. The DL1540C can only load the binary data file saved by the DL1540C. The DL1540CL can load the binary data file saved by the DL1540C and DL1540CL...

item: 617  |  http://tmi.yokogawa.com/mx/service-support/faqs/617/