Does the WT210/WT230 Conform to Energy Star's Guideline for Computers Ver. 4 approved meters?
Yes, the WT210 will meet or exceed all requirements set by the Energy Star guideline. Please see the attached documents for more details. ...
item: 73 | http://tmi.yokogawa.com/nr/service-support/faqs/73/
Which Yokogawa Instrument Supports CAN Bus Symbolic Decode?
Currently, the SB5000 and DLM2000 series oscilloscopes provide the CAN Bus symbolic decode analysis function. Once the zooming magnitude is enlarged, the indication appears automatically. The DL9000 does not provide CAN ...
item: 269 | http://tmi.yokogawa.com/nr/service-support/faqs/269/
Which Version of Excel can I use with the WE7000 Control Software?
Microsoft(R) Excel 97 and 2000 only....
item: 1162 | http://tmi.yokogawa.com/nr/service-support/faqs/1162/
How Do I Resolve the "LACK" Measurement Reading in DAQLOGGER When Connected to the WT230 via GateWT?
When making a WT230 RS232C connection using GateWT, please verify the following RS232C communication settings on the instrument: Mode = 488.2 Hand = 0 For = 0 Baud Rate = 9600 Terminator Cr+Lf Even though you can run Ga...
item: 939 | http://tmi.yokogawa.com/nr/service-support/faqs/939/
Is the RMS Method for Spectrum Width Calculation on the AQ6370C FOTP-127 Compliant?
The AQ6370C OSA was developed in accordance with the IEC standard: WG4 (IEC 61280-1-3) Test procedures for general communication subsystems -Central wavelength and spectral width measurement. We cannot guarantee the ...
item: 1308 | http://tmi.yokogawa.com/nr/service-support/faqs/1308/
If I Break a Passive Probe Such as the 700998 Within One Year of Purchase, is it Covered by a Warranty?
Because of their relative low cost, passive probes are classified as consumables and as such, are not covered by a warranty. More expensive probes such as the FET Probe and the Current Probe are covered by a warranty. ...
item: 100 | http://tmi.yokogawa.com/nr/service-support/faqs/100/
Why Can't I Find the WDM-NF Menu on the AQ6317 OSA?
Finding the WDM-NF function in the menu of the AQ6317 series of OSAs does not work in the same manner as the other functions on the OSA. Instead, you will need to depress the ANALYSIS key on the front of the OSA, and th...
item: 1070 | http://tmi.yokogawa.com/nr/service-support/faqs/1070/
How do I Update the Voltage and Current Range for the PZ4000 and WT1600 Using Communication Commands?
To change the voltage range on element 1 to 30 V, send the "INPUT:VOLTAGE:RANGE:ELEMENT1 30V" command to the measuring instrument.To change the current range on element 1 to the 1 A range, send the "INPUT:CURRENT:RANGE:...
item: 1250 | http://tmi.yokogawa.com/nr/service-support/faqs/1250/
Can the Screen Image Data on the DL1540 be Transferred via the GPIB Interface?
This function is available on firmware version 1.10 and higher. To check the version, press the MISC key on the front panel. and then select Information using the soft keys. This function is available on all versions of ...
item: 1202 | http://tmi.yokogawa.com/nr/service-support/faqs/1202/
Can I use GPIB to Remotely Control the DL850/DL850 but Save Data on a Shared Network Drive Using Ethernet?
Yes, you can use GPIB to remotely control the DL850/DL850 using Xviewer or LabVIEW and have the scope save data onto a shared network drive using the Ethernet interface. ...
item: 1299 | http://tmi.yokogawa.com/nr/service-support/faqs/1299/