DLM4000 Series Mixed Signal Oscilloscope (DISCONTINUED)

Notice: This product was discontinued on Feb 28, 2021. See this replacement product:

The DLM4000 is an eight-channel mixed-signal oscilloscope suitable to test and debugging applications in the embedded systems, power electronics, mechatronics, and automotive sectors. Available in both 350 MHz and 500 MHz models, the 2.5 GSa/sec DLM4000 features eight analog input channels. The eighth input channel features Flex MSO which converts to a 8-bit logic analyzer at the push of a button; add sixteen additional logic analyzer inputs as an option, for 24-bit logic analysis. Advanced measurement and analysis features such as power analysis and serial-bus analysis, digital filtering, user-defined math, and super-long record lengths (up to 250 Mega Points) make the DLM4000 a super powerful engineering tool. High-resolution 12.1-inch LCD display, compact landscape format, ergonomic and friendly user-interface make it easy to use.

The portable eight-channel DLM4000 is the daily instrument of choice

DLM4000 is the daily instrument of choice

Superior Functionality

Motor control & inverter circuit development

Yokogawa

Key to efficient and reliable high-performance electric motors is the modern inverter design, or ‘Intelligent Power Module’. Multi-channel, high-speed waveform measurement is an absolute necessity. Four channels are simply not enough. Boasting eight true analog inputs, the DLM4000 empowers today’s engineer with a convenient and comprehensive measurement system.

Limitation of 4 ch scope: Whole-system measurement is impossible with a four-channel scope; the real difficulty is measuring the timing between IGBT gate signals within the inverter. Voltage and current measurements between 3 phases and the IO of the motor driver IC is a very challenging test with a four-channel scope. The truly practical solution is an eight-channel MSO.

Electronic control unit & mechatronic test

Electronic control unit & mechatronic test

Numerous I/O analog, digital, and serial-bus waveforms surrounding the Electronic Control Unit (ECU) must be measured. The DLM4000 offers ample channel-count and architecture to monitor eight analog channels and up to 24-bits of logic input while simultaneously performing protocol analysis such as UART, I²C, SPI, CAN, CAN FD, LIN, CXPI, PSI5 and FlexRay. The DLM4000 can speed up the R&D process when four channels are not enough.

Limitation of 4 ch MSO: The additional logic inputs of a four-channel MSO mixed-signal oscilloscope provides enough channels, but this method has a blind-spot. Digital waveform analysis using logic inputs alone cannot reveal anomalies such as voltage drift, noise, distortion or ringing, and measure risefall times. ECU testing requires stringent examination of all digital waveforms- and analog input channels are the best tool for the job.

Reliable triggering

When just a specific event or abnormal waveform needs to be captured, the flexible and reliable triggering of the DLM4000 is the solution. In addition to basic trigger functions such as Edge, State, and Pulse Width- Advanced trigger types are provided, including Edge OR between multiple channels, Serial Bus trigger in which A combination of two bus signals is possible, or an A and B combination of different trigger types.

Reliable triggering

Best in Class Deep Memory & Architecture

Long waveform memory Up to 250 MPoints

The two advantages of a long waveform memory are the abilities to capture for long periods of time and to maintain high sample rates. Thus achieving higher effective measuring bandwidths for all time base settings.

Measuring time = Memory length / Sample rate

With the maximum memory installed (/M3 option), in single shot mode, a 10 kHz signal lasting for more than one hour can be captured. The same memory can capture a 200 millisecond signal at a sampling rate of 1.25 GS/s.

Two fully independent zoom windows
Enabling two fully independent zoom windows allows users to analyze the cause and effect of abnormal behaviors over all input channels. Users can also view and compare the details and timing of different serial buses operating at different speeds.

Yokogawa

History Function

The DLM4000 can capture and replay up to 50,000 individual acquisitions (/M3 option). These can be displayed one at a time or as an accumulation. Using the search and measurement functions, abnormal signals can therefore be quickly isolated, analyzed and precisely categorized without needing to carefully configure triggers to capture rare events.

History Search Function
Search up to 50,000 waveform history records based on detailed search parameters using the history search function.

History Search Function

Replay Function

Automatically play back, pause, fast forward, and rewind waveform history records.

Replay Function

Yokogawa

Additional Option License for DLM4000

This is a license product for adding applicable optional features on to DLM4000 series on your own.
It is necessary to update main unit firmware in advance to V3.03 and above* in order to apply this license.

* Firmware version 3.70 or higher is required to apply -F9, -X1 licenses.
* Firmware version 4.70 or higher is required to apply -10, -11 licenses.
* Firmware version 5.01 or higher is required to apply -F4, -F6, -F7, -F8 licenses.

Model Suffix code Description
709820 -G2 User defined math
-G3 Power supply analysis function
-G4 Power supply analysis function (includes G2)
-F1 UART trigger and analysis
-F2 I²C + SPI trigger and analysis
-F3 UART + I²C + SPI trigger and analysis
-F4 CAN + LIN trigger and analysis + CXPI analysis
-F5 FlexRay trigger and analysis
-F6 FlexRay + CAN + LIN trigger and analysis + CXPI analysis
-F7 CAN + CAN FD + LIN trigger and analysis + CXPI analysis
-F8 FlexRay + CAN + CAN FD + LIN trigger and analysis + CXPI analysis
-F9 SENT trigger and analysis
-10 PSI5 analysis
-11 SENT+PSI5 trigger and analysis
-X1 F4 -> F7 or F6 -> F8 (adds CAN FD)

 

Power Supply Analysis Function (/G3,/G4 option)

The /G3 and /G4 options enable switching loss, joule integral (I2t), SOA (safe operating area), harmonics based on EN61000-3-2, and other power parameters to be measured and analyzed.

Switching loss analysis:
The switching loss of the voltage and current input waveforms can be computed (U(t) x (I(t)) over long time periods. The turn-on/off loss, the loss including the continuity loss, and the loss over many cycles of the 50 Hz/60 Hz power line can be calculated and analyzed.

Yokogawa

Power Measurement
The DLM4000 can also be used as a power meter by providing automated measurement of power parameters for up to two pairs of voltage and current waveforms, such as the active power, apparent power and power factor. These values can be statistically processed and calculated.

Yokogawa

 

Related Accessories

Differential probe PBDH0150 (701927)
DC to 150 MHz
1000 Vrms/ ±1400 Vpeak

Yokogawa

Differential probe (701926)
DC to 50 MHz
5000 Vrms/7000 Vpeak

Yokogawa

Current probe PBC100/PBC050 (701928/701929)
DC to 100 MHz (701928)
DC to 50 MHz (701929)
30 Arms

Yokogawa

Deskew correction signal source (701936)

Yokogawa

 User defined math (/G2, /G4 option)

Equations can be arbitrarily created using a suite of operators such as trigonometric and logarithmic operators, integration and differentiation, pulse width operators, phase measurement and digital to analog conversion.

Yokogawa

Logic signal analysis (/L16 option)

The flexible MSO inputs are included as standard. This enables the DLM4000 to be converted to a 7 analog and 8 digital input MSO. With the /L16 option, up to 24 logic signals can be measured. Bus/State display and optional DA calculation function, which is useful for evaluating AD/DA converters, are also provided.

Yokogawa

Serial bus analysis function

UART (RS232)/ I²C/ SPI/ CAN/ CAN FD/ LIN/ FlexRay/ SENT/ PSI5/ CXPI
Dedicated trigger and analysis options are available for various serial buses of both in-vehicle and embedded systems. A wide variety of trigger combinations can be set, including ID and Data combinations, which can also be combined with conventional edge triggers. Trigger functions of some of the serial buses are not supported. Simultaneously display the physical layer waveforms and the digital data.

Serial bus auto-setup saves time
An intelligent serial bus auto-setup detects bit-rate and voltage threshold automatically and enables the DLM4000 to be quickly configured.

Up to 4 buses simultaneously

Analysis can be performed at high speed simultaneously on up to four different buses operating at different speeds. This is enhanced by the extensive search facilities, allowing the user to look for specific data in the very long memory. The dual-zoom facility means that different buses can be viewed and debugged alongside each other.

Yokogawa

Related Accessories

Differential probe PBDH1000 (701924)
DC to 1.0 GHz bandwidth 1 MΩ, approximately 1.1 pF
Maximum differential input voltage range: ±25 V

Yokogawa

Differential probe (701920)
DC to 500 MHz bandwidth
100 kΩ, approximately 2.5 pF
Maximum differential input voltage range ±12 V

Yokogawa

Logic probe PBL100/PBL250 (701988/701989)
100 MHz/250 MHz toggle frequency 1 MΩ, 10 pF/100 kΩ, 3pF

Yokogawa

 Broad connectivity and easy control

Yokogawa

PC connectivity and software tools

Yokogawa

 

Complement complex measurement tasks using a comprehensive suite of software tools.

Software Tools

LCA Reduced energy, emission of CO2, NOx and SOx about 25% compared to the previous model.

Results of Life Cycle Assessment
November. 1, 2017
  • Released new firmware version 5.01.
  • Added CXPI analysis option. (/F4,/F6,/F7,/F8)
November. 7, 2016
  • Released new firmware version 4.72.
  • Increased the maximum number of trend display from 1 to 4 in the SENT analysis function. (/F9,/F10)
October 13, 2016
  • New features added.
    • /F10 (PSI5 analysis option)
    • /F11 (SENT+PSI5 trigger and analysis option)
February. 17, 2016
  • Released new firmware version 4.43.
  • /F7, /F8 CAN FD analysis option revised to comply with ISO standard.
Model Description
DLM4038 DLM4038 350 MHz Mixed Signal Oscilloscope 8-channel 8-bit
DLM4058 DLM4058 500 MHz Mixed Signal Oscilloscope 8-channel 8 bit
Overview:
  • Construction and verification of SENT communication system
  • Accurate, reliable data transmission at low cost
Industries:
Overview:

While accurate rise time measurements have become easier to make, it remains, nonetheless, quite easy to overlook error contributions due to not only the oscilloscope but also the probe. And, while the error contributed by a scope's finite step-response (rise time) is often accounted for, that contributed by the probe is often overlooked.

Overview:

Frequency to Voltage Conversion   Problem: A transducer produces a sine-wave output dependant on the voltage-input; here is how to decode that output with a scope or a ScopeCorder.  For 3kV input, the transducer ...

Overview:

The free software DL-GATE can be used for the following products only:DL1700E seriesDL7400 series (firmware version after 1.32)DL1600 series (firmware version after 1.13)DL750 series (firmware version after ...

Overview:

This comprehensive training module covers the following topics:

  • Introduction & Product Familiarization
  • Basic Understanding and Operating Features
  • Advanced Analysis Features
  • Communication Features
Overview:

This training module covers the following topics:

  • Introduction & Installation 
  • Basics of Xviewer
  • Advanced features
  • Video Demonstrations 

Product Overviews

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making

Top