KNOWLEDGEBASE
(53) Results were found. Showing 1-10.
Can I Connect a Wireless Mouse or Keyboard to DL9000?
To use wireless mouses or keyboards on a device, a driver needs to be installed. Yokogawa instruments will not let you install drivers on the device, therefore it is not possible to connect a wireless mouse or keyboa...
item: 185 | http://tmi.yokogawa.com/sg/service-support/faqs/185/
Frequency to Voltage Conversion
Frequency to Voltage Conversion Problem: A transducer produces a sine-wave output dependant on the voltage-input; here is how to decode that output with a scope or a ScopeCorder. For 3kV input, the transducer outpu...
item: 1409 | http://tmi.yokogawa.com/sg/service-support/faqs/1409/
Why do I Need to use a Hub When Communicating With the Instrument via Ethernet?
The AC Power Input in all Yokogawa instruments is designed as a 3-pin connection (one of which is a GND pin). In some parts of the world, PCs are sold with AC power cables that are 2-pin. Often times this means the PC d...
item: 906 | http://tmi.yokogawa.com/sg/service-support/faqs/906/
Where can I Find Documentation Describing the *.WDF File Format?
Unfortunately, we do not have an instruction manual describing the*.WDF file format structure like we did for the *.WVF files. However, we do provide a list of support options which will contain more details and explana...
item: 1042 | http://tmi.yokogawa.com/sg/service-support/faqs/1042/
Is There any way to Save Waveform Data Whose Record Length Exceeds 1.25 Mpts in ASCII CSV Format?
The DLM2000 will prohibit any attempts to save a waveform in CSV format if the file is larger than 1.25 Mpts. There are two methods to work around this issue: Compress the data using the Data Compression feature on the ...
item: 200 | http://tmi.yokogawa.com/sg/service-support/faqs/200/
What is Hi-Resolution Mode?
High Resolution mode can be used to remove high frequency noise and increase vertical resolution. It achieves this by increasing the number of effective bits per data to 12-bits through digital and bandwidth filters. Th...
item: 1076 | http://tmi.yokogawa.com/sg/service-support/faqs/1076/
What is Decimation and How do I use Decimation in Xviewer?
Decimation is a technique used to reduce the total number of samples. You can use Xviewer to perform decimation on your waveform data files that have the WDF/WVF/ASCII CSV extension format. Decimation reduces the total n...
item: 1029 | http://tmi.yokogawa.com/sg/service-support/faqs/1029/
How Can I Effectively Achieve a Sample Rate Less Than 5 Sa/sec on the DL850?
The lowest possible device setting for sample rate on the DL850 is 5 Sa/sec. There are however, different methods that will allow you to achieve much lower sample rates which includes the use of an external clock, decim...
item: 1003 | http://tmi.yokogawa.com/sg/service-support/faqs/1003/
Why Doesn't Microsoft Snapshot Viewer Open Yokogawa .SNP Files?
The Yokogawa .SNP file is a proprietary Yokogawa file format for saving waveform snapshots. This file has no relation to the Microsoft Snapshot Viewer program. The .SNP file can only be viewed on the oscilloscope. ...
item: 37 | http://tmi.yokogawa.com/sg/service-support/faqs/37/
Which Yokogawa Instrument Supports CAN Bus Symbolic Decode?
Currently, the SB5000 and DLM2000 series oscilloscopes provide the CAN Bus symbolic decode analysis function. Once the zooming magnitude is enlarged, the indication appears automatically. The DL9000 does not provide CAN ...