Why Isn't the FFT Results Displayed on the DL1540 When Performing an FFT Analysis?
If the FFT does not appear, check to assure that the horizontal position of the waveform is set exactly to Zero. If the horizontal position is set to a non-zero value, the FFT will not be performed. ...
item: 1192 | http://tmi.yokogawa.com/sg/service-support/faqs/1192/
What is the DL850 GigaZoom II?
GigaZoom II is a display processor implemented via architectural technology on an FPGA. ...
item: 722 | http://tmi.yokogawa.com/sg/service-support/faqs/722/
Xviewer 1.70 Math Issue
Xviewer 1.70 Math Issue Normally, for the math expression 'Mn' (when n...
item: 1342 | http://tmi.yokogawa.com/sg/service-support/faqs/1342/
Can a Large Data File be Saved Onto Multiple Floppy Disks With the DL1540L?
Yes, if all the data cannot fit onto one disk, a message will appear prompting you to enter the next floppy disk. Simply follow the instructions to save the data to multiple floppy disks. The same procedure also applies ...
item: 1183 | http://tmi.yokogawa.com/sg/service-support/faqs/1183/
Does the /JSxx Option Work for Xviewer Using Files Created on a DL750?
Unfortunately, it does not work for the files created on a DL750. It is a dedicated feature available only for the DL850/DL850V. ...
item: 802 | http://tmi.yokogawa.com/sg/service-support/faqs/802/
Can the AQ6370 OSA Load and Re-Display the Data SAved by an AQ6370B?
The AQ6370 OSA cannot load and re-display the data saved by an AQ6370B. However, the AQ6370 Viewer software can display the data saved by both instruments. Also please note that the AQ6370B OSA can load and re-display th...
item: 638 | http://tmi.yokogawa.com/sg/service-support/faqs/638/
Can Multiple GS Units be Connected in Series/Parallel to Boost the Output Voltage/Current?
It is possible to connect multiple GS units in series/parallel connections to boost the maximum voltage/current, provded the values are within the range of maximum voltage/current of those limiters. To amplify the output...
item: 597 | http://tmi.yokogawa.com/sg/service-support/faqs/597/
Why Doesn't the Theoretical Power Value Match the Measured Power Value?
Check for differences in the specifications or features of the instruments. For values that do not match when inputting a 50/60 sine wave Check whether the value is within the specifications (error) of each power meter...
item: 1258 | http://tmi.yokogawa.com/sg/service-support/faqs/1258/
How Do the Line & Frequency Filters Affect Signals Close to the Filter Cutoff Frequency?
The circuit design for the line filters used on the WT & PZ series instruments are similar to Butterworth filters but have been redesigned. We redesigned the original filtering characteristic to obtain a sharper rolloff ...
item: 912 | http://tmi.yokogawa.com/sg/service-support/faqs/912/
Are the Standard Operating Conditions for the DL850 Equivalent to the Compensated Temperature Range?
No, the Standard Operating Conditions are not equivalent to the compensated temperature range. The unit's accuracy specifications are valid when operated within the Standard Operating Conditions and when the temperature ...
item: 1296 | http://tmi.yokogawa.com/sg/service-support/faqs/1296/