The 733 Digital Multimeter features: 3.5 digits (4,000-count, 40-segment bar graph display), Mean value type (733 01, 73302), RMS type (73303)Measurement Functions : Voltage, Current, Resistance, Continuity Check, Diode Test, Frequency, Capacitance, Temperature
Features : User calibration function (73302, 73303), Hi-impact overmold case
Additional Functions | Relative and percentage value computation, data / auto hold, overvoltage warning |
---|---|
Display | Digital display: 4,000-count digital reading; 40-segment bar graph |
Measuring Rate | Digital display: 2.3 times/sec Bar graph display: 23 times/sec |
Operating Temp and Humidity | -10°C to 50°C; 80% RH or less at -10°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
Storage Temp and Humidity | -20°C to 60°C, 70 RH or less (no condensation) |
Temperature Coefficient | Add the accuracy ( 0.1/°C to the basic accuracy at a temperature within -10°C to 18°C and 28°C to 50°C) |
Withstanding voltage | 5.55 kV AC for 1 minute (between input terminals and casing) |
DC Voltage Accuracy | 0.3% + 1 |
AC Voltage Accuracy | 1% + 2 |
DC Current Accuracy | 1% + 2 |
AC Current Accuracy | 1% + 2 |
DC Voltage Measurement @ 40 V | 0.3% + 1 |
AC Voltage Measurement @ 40 V | 1% + 2 @ 50-50 Hz 1.5% + 4 @ 500 Hz - 1kHz 5% + 2 @ 50/60 Hz |
Power Supply | Two AA (R6) dry cells |
Battery Life1 | 1000 hours |
Auto power-off | The power is automatically turned off when no operation is made for approx. 20 minutes (can be disabled). |
Dimensions | 85 (W) x 19.1 (H) x 40 (D) mm |
Weight | Approximately 450 g (including batteries) |
Compliance with Standards | Safety EN61010-1 (1995); EN61010-2-031 (1995) (AC/DC 1000 V, CAT II; AC/DC 600 V, CAT III) EMC - EMI: EN55011 (1998); EN61326-1 (1998) + A1 (Class B, Group 1) EMS: EN50082-1 (1997); EN61326-1 (1998) + A1 |
Standard Accessories | AA (R6) dry cells (built in) :2 Instruction manual: 1 Test lead set (RD031) :1 |
Optional Accessories | Carrying Case (hard) Hoses the DMM and test leads (B9646HH) Fuse 500 mA/600 V (A1518EF) Thermistor Probe -50°C to 150°C (234901) |
Response Time | 2 seconds or less |
Conforms to EN61010-10 Safety Standard | Conforms to overvoltage category AC/DC 1000 V, CAT II, and AC/DC 600 V CATIII. |
Use in the Field Safe Design Prevents Human Error | Terminal shutters prevent erroneous insertion of test leads into current measurement terminals |
Increased Safety | If the function is switched to voltage measurement while a test lead is left inserted into a current measurement terminal, neither the fuse built into the current measurement circuit of the DMM nor the input protection circuit for voltage measurement can protect the circuits. The terminal shutters prevent the rotary switch from being moved from the current measurement function while a test lead is inserted into a current measurement terminal, thus preventing erroneous settings due to human error and ensuring the safety of the user. The terminal shutters open and close with operation of the function select (rotary) switch, so operation efficiency is not sacrificed. |
Employs High-Performance Fuses Rated @ 100 kA | Uses withstand current fuses with an arc extinguishing material for an assured prearcing time-current characteristic in the event of an excessive current. Rated breaking current: 100 kA for both |
Elastomer Material Used for Impact Absorption | An elastomer material that provides better grip and impact resistance than conventional ABS resin or polycarbonate is used for the casing of the meter thus improving both safety and ease of use. |
Additional Functions | Relative and percentage value computation, data / auto hold, overvoltage warning |
---|---|
Display | Digital display: 4,000-count digital reading; 40-segment bar graph |
Measuring Rate | Digital display: 2.3 times/sec Bar graph display: 23 times/sec |
Operating Temp and Humidity | -10°C to 50°C; 80% RH or less at -10°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
Storage Temp and Humidity | -20°C to 60°C, 70 RH or less (no condensation) |
Temperature Coefficient | Add the accuracy ( 0.1/°C to the basic accuracy at a temperature within -10°C to 18°C and 28°C to 50°C) |
Withstanding voltage | 5.55 kV AC for 1 minute (between input terminals and casing) |
DC Voltage Accuracy | 0.2% + 1 |
AC Voltage Accuracy | 1% + 5 |
DC Current Accuracy | 0.5% + 2 |
AC Current Accuracy | 1.5% + 2 |
DC Voltage Measurement @ 40 V | 0.2% + 1 |
AC Voltage Measurement @ 40 V | 1% + 2 @ 50-50 Hz 1.5% + 4 @ 500 Hz - 1kHz 5% + 2 @ 50/60 Hz |
Power Supply | Two AA (R6) dry cells |
Battery Life1 | 350 hours |
Auto power-off | The power is automatically turned off when no operation is made for approx. 20 minutes (can be disabled). |
Dimensions | 85 (W) x 19.1 (H) x 40 (D) mm |
Weight | Approximately 450 g (including batteries) |
Compliance with Standards | Safety EN61010-1 (1995); EN61010-2-031 (1995) (AC/DC 1000 V, CAT II; AC/DC 600 V, CAT III) EMC - EMI: EN55011 (1998); EN61326-1 (1998) + A1 (Class B, Group 1) EMS: EN50082-1 (1997); EN61326-1 (1998) + A1 |
Standard Accessories | AA (R6) dry cells (built in) :2 Instruction manual: 1 Test lead set (RD031) :1 |
Optional Accessories | Carrying Case (hard) Hoses the DMM and test leads (B9646HH) Fuse 500 mA/600 V (A1518EF) Thermistor Probe -50°C to 150°C (234901) |
Response Time | 2 seconds or less |
Conforms to EN61010-10 Safety Standard | Conforms to overvoltage category AC/DC 1000 V, CAT II, and AC/DC 600 V CATIII. |
Use in the Field Safe Design Prevents Human Error | Terminal shutters prevent erroneous insertion of test leads into current measurement terminals |
Increased Safety | If the function is switched to voltage measurement while a test lead is left inserted into a current measurement terminal, neither the fuse built into the current measurement circuit of the DMM nor the input protection circuit for voltage measurement can protect the circuits. The terminal shutters prevent the rotary switch from being moved from the current measurement function while a test lead is inserted into a current measurement terminal, thus preventing erroneous settings due to human error and ensuring the safety of the user. The terminal shutters open and close with operation of the function select (rotary) switch, so operation efficiency is not sacrificed. |
Employs High-Performance Fuses Rated @ 100 kA | Uses withstand current fuses with an arc extinguishing material for an assured prearcing time-current characteristic in the event of an excessive current. Rated breaking current: 100 kA for both |
Elastomer Material Used for Impact Absorption | An elastomer material that provides better grip and impact resistance than conventional ABS resin or polycarbonate is used for the casing of the meter thus improving both safety and ease of use. |
Additional Functions | Relative and percentage value computation, data / auto hold, overvoltage warning |
---|---|
Display | Digital display: 4,000-count digital reading; 40-segment bar graph |
Measuring Rate | Digital display: 2.3 times/sec Bar graph display: 23 times/sec |
Operating Temp and Humidity | -10°C to 50°C; 80% RH or less at -10°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
Storage Temp and Humidity | -20°C to 60°C, 70 RH or less (no condensation) |
Temperature Coefficient | Add the accuracy ( 0.1/°C to the basic accuracy at a temperature within -10°C to 18°C and 28°C to 50°C) |
Withstanding voltage | 5.55 kV AC for 1 minute (between input terminals and casing) |
DC Voltage Accuracy | 0.2% + 1 |
AC Voltage Accuracy | 1% + 5 |
DC Current Accuracy | 0.5% + 2 |
AC Current Accuracy | 1.5% + 2 |
DC Voltage Measurement @ 40 V | 0.2% + 1 |
AC Voltage Measurement @ 40 V | 1% + 2 @ 50-50 Hz 1.5% + 4 @ 500 Hz - 1kHz 5% + 2 @ 50/60 Hz |
Power Supply | Two AA (R6) dry cells |
Battery Life1 | 350 hours |
Auto power-off | The power is automatically turned off when no operation is made for approx. 20 minutes (can be disabled). |
Dimensions | 85 (W) x 19.1 (H) x 40 (D) mm |
Weight | Approximately 450 g (including batteries) |
Compliance with Standards | Safety EN61010-1 (1995); EN61010-2-031 (1995) (AC/DC 1000 V, CAT II; AC/DC 600 V, CAT III) EMC - EMI: EN55011 (1998); EN61326-1 (1998) + A1 (Class B, Group 1) EMS: EN50082-1 (1997); EN61326-1 (1998) + A1 |
Standard Accessories | AA (R6) dry cells (built in) :2 Instruction manual: 1 Test lead set (RD031) :1 |
Optional Accessories | Carrying Case (hard) Hoses the DMM and test leads (B9646HH) Fuse 500 mA/600 V (A1518EF) Thermistor Probe -50°C to 150°C (234901) |
Response Time | 2 seconds or less |
Conforms to EN61010-10 Safety Standard | Conforms to overvoltage category AC/DC 1000 V, CAT II, and AC/DC 600 V CATIII. |
Use in the Field Safe Design Prevents Human Error | Terminal shutters prevent erroneous insertion of test leads into current measurement terminals |
Increased Safety | If the function is switched to voltage measurement while a test lead is left inserted into a current measurement terminal, neither the fuse built into the current measurement circuit of the DMM nor the input protection circuit for voltage measurement can protect the circuits. The terminal shutters prevent the rotary switch from being moved from the current measurement function while a test lead is inserted into a current measurement terminal, thus preventing erroneous settings due to human error and ensuring the safety of the user. The terminal shutters open and close with operation of the function select (rotary) switch, so operation efficiency is not sacrificed. |
Employs High-Performance Fuses Rated @ 100 kA | Uses withstand current fuses with an arc extinguishing material for an assured prearcing time-current characteristic in the event of an excessive current. Rated breaking current: 100 kA for both |
Elastomer Material Used for Impact Absorption | An elastomer material that provides better grip and impact resistance than conventional ABS resin or polycarbonate is used for the casing of the meter thus improving both safety and ease of use. |
Model | Description |
---|---|
73303 | DC Voltage Accuracy 0.2% + 1; AC Voltage Accuracy 1% + 5; DC Current Accuracy 0.5% + 2; AC Current Accuracy 1.5% + 2; Battery Life 350 Hours |
73301 | DC Voltage Accuracy 0.3% + 1; AC Voltage Accuracy 1% + 2; DC Current Accuracy 1% + 2; AC Current Accuracy 1% + 2; Battery Life 1000 Hours |
73302 | DC Voltage Accuracy 0.2% + 1; AC Voltage Accuracy 0.5% + 2; DC Current Accuracy 0.5% + 2; AC Current Accuracy 1.5% + 2; Battery Life 350 Hours |