SL1000 HIGH-SPEED DATA ACQUISITION UNIT

The new Yokogawa SL1000 is the only data acquisition system that delivers independent, isolated channel hardware at 100MS/ch rates, with no compromise in bit resolution, memory depth, or streaming performance.

See more images:

 
 

Selecting a data acquisition platform for electronics or mechatronics applications has always been a balancing act. High speed digitizers lack the isolation, attenuation, or bit resolution necessary for power electronics testing. PC-based platforms with fast streaming throughput sacrifice noise immunity, signal conditioning, and hardware integrity.

Until now. The new Yokogawa SL1000 is the only data acquisition system that delivers independent, isolated channel hardware at 100MS/ch rates, with no compromise in bit resolution, memory depth, or streaming performance.

Speed of managing and acquiring data is the highlight of the SL1000.

  • Fast Acquisition
    • Up to 100 MS/s on all channels (10 ns sampling interval)
    • New 100 MS/s 12-Bit 1 kV¹ isolation module with 20 MHz bandwidth
    • Supports parallel testing: Perform measurements with up to four simultaneously independent sample rates
  • Fast Transfer and Storage
    • Stream data to PC via high speed USB 2.0 or 1000BASE-T Gigabit Ethernet²
    • Real time display on a PC (GIGAZoom engine)³
    • Stream data to a PC hard disk or the SL1000's internal hard disk² in real time (at speeds of 1.6 MS/s = 100 kS/s x 16ch)³ 
  • Easy to use
    • Easy to use Standard Acquisition Software
    • Quick and Intuitive operation means that you can start measuring immediately
    • Setup Wizard guides you through detailed settings
  • Can operate "Standalone"
    • Store data directly on the SL1000
  • Wide Library of Plug-In Modules
    • Eight module slots are available in each unit
    • Select from twelve different plug-in modules

¹: In combination with 10:1 probe (for isolated BNC input) model 700929
²: Optional
³: Speed depends on PC performance and measuring conditions.


High-Speed Capture

In the pursuit of isolated high-speed waveform measurements, Yokogawa has achieved a maximum sample rate of 100 MS/s (10 ns sampling interval). The SL1000 can accurately capture high-speed and high-voltage phenomena by using the newly developed 100 MS/s, 12-Bit resolution,  20 MHz frequency range and 1-kV * Isolation Module (model 720210).
Furthermore, you can combine modules that support measurements of a variety of signals, giving you solutions for an extensive range of applications.

*: In combination with 10:1 probe (for isolated BNC input ) model 700929


 High Speed Capture


Saving Data over Long Periods of Time

Data can be saved to the SL1000’s internal acquisition memory over long durations, or it can also be streamed in real-time to a PC's hard disk or the SL1000’s internal hard disk ¹ ².

Sample Rate V Recording Time


¹:  with the /HD1 Option
²:  Maximum speed of real time hard disk recording depends on measuring conditions.
³:  Trigger mode: Single, measuring on 1 module, 2 channels.  

Supports parallel testing 

Perform measurements with up to four simultaneously independent sample rates. The amount of data saved on hard disk can be reduced by optimizing the sample rate for the DUT on a module by module basis.

Support Parallel Testing

High-Speed Data Transfer & GIGAZoom Function 

You can transfer data to the PC at high speeds via USB 2.0 or Ethernet 1000BASE-T Gigabit Ethernet¹. The SL1000’s high-speed data compression engine (GIGAZoom engine) displays waveforms on the PC in real time² (even with massive amounts of data at high sample rates).  It offers the same display updating and zooming performance as standalone measuring instruments.

¹:  with the /C10 Option
²:  The number of channels from which waveforms can be displayed during measurement may be limited depending on the PC performance and measuring conditions.

Giga Color Black R


Giga Zoom Function

Real Time Saving to Hard Disk 

Continuously measured data can be saved in real time to a PC's hard disk and/or the SL1000's internal hard disk ¹. File names are assigned automatically, freeing you from time consuming file operations. Data can be saved simultaneously - and in real time - to both the PC’s and SL1000's hard disks ¹. This bolsters the reliability of your data storage system, protecting your vital data. You can access the SL1000's internal hard disk ¹ with Xviewer waveform viewer software, or through an FTP client over Ethernet ².

Real Time Saving To Hard Disk 2

Real Time Saving To Hard Disk 

¹: with the /HD1 Option
²: with the /C10 Option
³: Typical values. Actual values depend on PC performance and measurement conditions.

Settings for the Hard Disk Recording Function 

By using the various recording features, you can efficiently and automatically record only the data you need to the hard disk. Just specify the recording destination, recording start and stop conditions, conditions for repeating recording, and other criteria. With free run mode, the specifiable parameters for the recording start condition are immediate, time, and alarm; for the recording stop condition, the parameters are continuous, time, recording time, and alarm; and for the repeating condition, recording interval and number of recordings*. With triggered mode, measured data is recorded on each trigger. You can also manually save data from the SL1000's internal acquisition memory to PC hard disk.

*: Max. file size per recording is 12 GB (recording on 4 channels, approximately 1.5 GW/ch)

Setting Hard Disk Recording Function

Multi Units Synchronization

Maximum 8 Synchronized Units

  • 100 MS/s up to 128 ch (16ch x 8 units)
  • Can use 4 different sample rates across all units
  • (Supports Parallel testing)
  • Can combine trigger and alarm for channels across all units
  • Maximum speed for saving in real time1
  • PC HDD: 1.6 MS/s = 100kS/s x 16ch > 10kS/s x 128ch (Total data transfer rate to PC HDD is 1.6MS/s) Unit HDD: 1.6MS/s = 100kS/s x 16ch (100kS/s x 128ch with 8 units)
1: Typical values. Actual values depend on PC performance and measurement conditions

Tm Sl1000 20

(Note)
In synchronized unit mode, recording into PC and SL1000 embedded HDD at the same time is not possible.
The recording file is per unit basis. (Utility software interface.)

Setting Marks (NEW)


You can input the comments in the mark area when monitoring (Free run mode) over long periods of time.

SL1000 Software 1 Setting Marks
You can input the comments in the mark area when monitoring (Free run mode) for a long time.



Real time X-Y Display (NEW)

You can now see both the T-Y and X-Y waveform Display. It is easy to evaluate data with fast update.
SL1000 Software 2 2

Auto Play (NEW)

It is easy to set zoom position of waveform when measuring over long periods of time data or large data.

SL1000 Software 3 1


SL1000 Software 4

File Utility Function (NEW)

You can save the data in both ASCII and Binary format. You can also load data with the same analysis program (ex. MatLAB).

SL1000 Software 5

Setting Operation Display

Accumulating Waveforms (NEW)

You can easily detect unevenness or changes in acquired data.

SL1000 Software 6


Sample of Accumulate Display

Setup Wizard Makes It Easy 

The Wizard automatically recognizes any connected SL1000 and its' plug-in modules. Just click the Start button to start measuring right away - no complicated settings to enter. The four screens of the Setup Wizard guide you easily through detailed settings for configuring the system, measuring, saving and displaying. Of course, you can save and recall your settings at any time.

Setup Wizard

Individual Sample Rates for Each Measurement Channel Group 

Up to four groups of measurement channels can be defined with individual measurement conditions and display settings. Even waveforms from groups with different sample rates can be displayed in the same window.

Individual Sample Rate

Easy Tabular Setup Screens 

Measurement conditions and channel display settings can be viewed and set easily using a tabular format. Use drag and drop shortcuts to quickly setup multiple channels.

Easy Tabular Setup

Measurement condition setting screen Display setting screen

 

Control Buttons - Just Like Your DVD Remote 

Measurement and saving can be started and stopped using the same familiar buttons found on a DVD remote control. Start using the instrument on the same day you receive it, with absolutely no programming required. 

Control Button 

 

Real Time Waveform Display and Analysis 

You can display a zoomed portion of the waveform simultaneously with the overall waveform during triggered measurement. Even during live recording, you can use the display hold * to review past data. You can also perform cursor measurements or automated measurement of waveform parameters (up to 26 during triggered measurement) in real time.

*:  The display hold may automatically switch to display resume depending on the measuring conditions.  

Easy Display Setup

Adjust your vertical display scale with ease using mouse shortcuts.

Tm Sl1000 21

File Transfer

Adjust your vertical display scale with ease using mouse shortcuts.The File Transfer Function transfers files from the SL1000 to PC via, the Acquisition Software, intelligently in the case of multiple synchronized units.

Tm Sl1000 22

File Utility *

SL1000 File Utility is file processing software for manipulating acquired files before analyzing waveforms with Xviewer. It can also analyze multiple channels across several units at the same time.

* SL1000 File Utility is bundled with the SL1000 standard install CD.

 Tm Sl1000 23
File interface operation screen (example)
  Tm Sl1000 24
Name Description File Type  
Bulletin 7201-20E SL1000 High-Speed Data Acquisition Unit pdf icon
1.30 MB
Download
SL1000V2-PMK01E High Speed Data Acquisition Unit SL1000 Ver. 2 pdf icon
460 KB
Download
SL1000 EPICS driver specifications Experimental Physics and Industrial Control System (EPICS) support for SL1000 digitizer modules pdf icon
280 KB
Download
Bulletin 7201-20V21E SL1000 Acquisition Software V2.10 pdf icon
334 KB
Download
Name Description  
Observation of Inverter Switching Waveforms Observation of Inverter Switching Waveforms Learn More
Surge Waveform Recording & Power Monitoring Surge Waveform Recording & Power Monitoring Learn More
Acquisition of Explosion and Combustion Data Acquisition of Explosion and Combustion Data Learn More
Name Description  
Acquisition Software ver 2.10 Ver 2.10 meets the demands of high channel count and easy data operation. y-Link
LabVIEW Drivers for SL1000 LabVIEW drivers for SL1000 y-Link
MATLAB Control Tool Kit This MATLAB tool kit enables DL (M) Series to easily interface with MATLAB. The software can be used to control supported DL series instruments from MATLAB or to transfer data from DL series instruments to MATLAB via GP-IB, USB or Ethernet. Learn More
MATLAB Control Tool Kit - 701991 (trial version) This MATLAB tool kit enables DL (M) Series to easily interface with MATLAB. The software can be used to transfer data from DL series instruments to MATLAB via GP-IB, USB or Ethernet.
y-Link
MATLAB Control Tool Kit - 701991 (upgrade version) This MATLAB tool kit enables DL (M) Series to easily interface with MATLAB. The software can be used to transfer data from DL series instruments to MATLAB via GP-IB, USB or Ethernet. y-Link
USB Driver The USB Driver is needed when required by the software. y-Link
XViewer 701992 Xviewer allows you to display acquired waveform data (using the “Viewer” function), perform file transfers, and control DL (M) Series from a PC via GP-IB, USB or Ethernet. Learn More
Yokogawa_WDF DataPlugin NI DIAdem is a single software tool that you can use to quickly locate, load, visualize, analyze, and report measurement data collected during data acquisition and/or generated during simulations. The Yokogawa_WDF DataPlugin supports the reading of Yokogawa Waveform Data Files (WDF).
Learn More

720210 Analog Voltage Input Module

720210 Analog Voltage Input Module

High-Speed 100 MS/s 12-Bit Isolation Module (2 channels)

IsoPRO technology enables 1kV isolated measurements in combination with 700929 or 701947 probe and is designed for inverter / IGBT related applications in mind. Using high speed optical fiber-based transmission, the module achieves high speed ADC clock and data isolation and provides the performance needed to develop high  efficiency inverters, which employ high voltages, large currents, and ever increasing switching speeds.

701250 Analog Voltage Input Module

701250 Analog Voltage Input Module

High-Speed 10 MS/s 12-Bit Isolation Module (2 ch)

701251 Analog Voltage Input Module

701251 Analog Voltage Input Module

High-Speed 1 Ms/s 16-Bit Isolation Module (2 channels)

With high sensitivity range (1mV/div), low noise (±100 μVtyp.), and high noise immunity

701255 Analog Voltage Input Module

701255 Analog Voltage Input Module

High-Speed 10 MS/s 12-Bit non-isolation Module (2 ch)

701260 Analog Voltage Input Module

701260 Analog Voltage Input Module

High-voltage 100 kS/s 16-Bit Isolation Module (with RMS, 2 ch)

701261 Universal Voltage & Temperature Input Module

701261 Universal Voltage & Temperature Input Module

Universal Module (2 channels)

Accepts thermocouple (K, E, J, T, L, U, N, R, S, B, W, irondoped gold/chromel)

701262 Universal Voltage & Temperature Input Module (w/AAF)

701262 Universal Voltage & Temperature Input Module (w/AAF)

Universal Module with Anti-Aliasing Filter (2 channels)

Accepts thermocouple (K, E, J, T, L, U, N, R, S, B, W, irondoped gold/chromel), with Anti Aliasing Filter

701265 High-Precision Temperature Input Module

701265 High-Precision Temperature Input Module

Temperature/high-precision voltage Module (2 channels)

Accepts thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (0.1mV/div), and low noise (±4 μVtyp.)

701270 - Strain Input Module (NDIS)

701270 - Strain Input Module (NDIS)

Strain Module, type NDIS (2 channels) to be used in combination with 701955 or 701956 NDIS bridge head.

Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.

701271 - Strain Input Module (DSUB)

701271 - Strain Input Module (DSUB)

Strain Module with Shunt Calibration, type DSUB (2 channels) to be used in combination with 701957 or 701958 DSUB bridge head.

Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.

701275 Acceleration & Voltage Input Module (w/AAF)

701275 Acceleration & Voltage Input Module (w/AAF)

Acceleraton/Voltage Module with Anti-Aliasing Filter, (2 channels)

Accepts direct input from a built-in amp type acceleration sensor to measure acceleration. Sensor supply current (voltage) OFF/4 mA ± 10% (approx. 22 VDC) Applicable acceleration sensor  type: Built-in amplifier type, Kistler Instruments Corp. : PiezotronTM, PCB, Piezotronics Inc. : ICPTM, Endevco Corp : IsotronTM.

700929 10:1 Probe

700929 10:1 Probe

Passive Probe, 1000Vp CAT II, 100MHz, 10:1, 10MΩ, 1.5m, Isolated Probe, Iso-Probe
Please see also 701947 & accessories.

701940 10 MHz Passive Probe

701940 10 MHz Passive Probe

Passive Probe, 600Vp, 6MHz/10MHz, 1:1, 10:1, 1MΩ/10MΩ, 1.5m '600V Non-Isolated'

701930 Current Probe 10 MHz/150 ARMS

701930 Current Probe 10 MHz/150 ARMS

Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

701931 Current Probe 2 MHz/500 ARMS

701931 Current Probe 2 MHz/500 ARMS

Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

701933 Current Probe 50 MHz/30 ARMS

701933 Current Probe 50 MHz/30 ARMS

Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

701934 Probe Power Supply

701934 Probe Power Supply

A power supply for current probes, FET probes, and differential probes. Supplies power for up to four probes, including large current probes.



701901 1:1 BNC safety adapter lead

701901 1:1 BNC safety adapter lead

1000 Vrms-CAT II, 1.8 m long
Safety BNC(male) to safety banana(female) use in combination with 701959, 701954, 758921, 758922 or 758929.

366926 BNC cable

366926 BNC cable

A 1 m long BNC-alligator clip cable. Use only for circuits having voltage levels no greater than 42 V.

366961 Measurement lead

366961 Measurement lead

A subassembly of 1.2 m long test leads with alligator-clip adapters. Use only for circuits having voltage levels no greater than 42 V.

701902/701903 Safety BNC cable

701902/701903 Safety BNC cable

701902: 1000 Vtms-CAT II (BNC-BNC), 1 m
701903: 1000 Vrms-CAT II (BNC-BNC), 2 m

701954 Alligator clip (dolphin type)

701954 Alligator clip (dolphin type)

Set contains one black and one red clip.1000 Vrms-CAT II.

701955�701956 NDIS bridge heads

701955�701956 NDIS bridge heads

701955 NDIS Bridge Head, Bridge resistance: 120Ω , 5m NDIS cable included

701956 NDIS Bridge Head, Bridge resistance: 350Ω , 5m NDIS cable included

701957�701958 D-sub bridge heads

701957�701958 D-sub bridge heads

701957 DSUB Bridge Head with Shunt calibration
Bridge resistance:  120Ω , 5m DSUB cable included

701958 DSUB Bridge Head with Shunt calibration
Bridge resistance:  350Ω , 5m DSUB cable included

701959 Safety mini clip (hook type)

701959 Safety mini clip (hook type)

Set contains one black and one red clip. 1000 Vrms-CAT II.

758921 Fork terminal adapter

758921 Fork terminal adapter

Adapters for fitting a 4mm banana plug to a fork terminal. Set contains one black and one red clip
1000 Vrms-CAT II.

758922 Small Alligator-clip Adapter

758922 Small Alligator-clip Adapter

Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.

758929 Large Alligator-clip Adapter

758929 Large Alligator-clip Adapter

Rated at 1000V. Attaches to the 758917 test leads. Sold in pairs.

758924 Conversion Adapter

758924 Conversion Adapter

For conversion between BNC and female banana plug

 

All Products Guide
All Products Guide
PDF (8.40 MB)
CALL TOLL-FREE AT
1-800-888-6400
(8:00 TO 17:00 EASTERN)
y-Link