701927 DIFFERENTIAL PROBE 1400V / 150 MHZ

The 701927 is a 50:1 or 500:1 high voltage (1400V peak) probe with extended bandwidth covering DC to 150MHz, This probe provides a balanced differential input, to be used with oscilloscopes with single-ended inputs (1 MΩ Input Impedance).  This probe works with DLM2000, DLM4000, DL6000, DLM6000, DL9000 and SB5000. This probe is conveniently powered by the Yokogawa Probe Interface I/F.

Get a Quote
Ask an Expert

 
 

1400 Vpeak capability is suitable for un-grounded and floating voltage measurements in power electronics and mechatronics applications including inverters, motor drives, and power supplies. 1 m long extension lead pair is included as a standard accessory. Standard pincher tips are exchangeable a wide variety of 4mm safety adapters (sold separately). Reduced size and weight over comparable probes (50% reduced volume over the Yokogawa 700924).

Specifications

Input type Balanced differential input
Frequency band DC TO 150 MHz (-3 dB)
Input attenuation ratio 50:1 and 500:1, user selectable
Input impedance Approximately 4 MΩ
Maximum allowed differential voltage ± 1400 V(DC+ACpeak) (1/500)
Maximum common mode input voltage ± 1400 V(DC+ACpeak) or 1000 Vrms
Common Mode Rejection Ratio (CMRR) -80 dB (60 Hz), -50 dB (1 MHz)
Output voltage ±2.8 V
Output impedance Used with 1 MΩ input impedance
Power Supply Yokogawa Probe Interface Only
External dimensions (approximate) 174 mm x 58 mm x 27 mm
Total length Approximately 2.4 meters
Weight Approximately 500 grams
Approved standards  
Name Description File Type  
PBDH0150 (701927) Product brochure for the 701927 Differential probe pdf icon
666 KB
Download
 

All Products Guide
All Products Guide
PDF (26.47 MB)
CALL TOLL-FREE AT
1-800-888-6400
(8:00 TO 17:00 EASTERN)
y-Link