NEW BIG LOOK ANALOG PANEL METERS

  • AC/DC-Amps/Volts and Frequency
  • Extra-wide scales with big bold numerals
  • Taut Band and Pivot and Jewel Movements
  • UL/CUL Option Available

Get a Quote
Ask an Expert

 
 

New Big Look analog panel meters feature extra-wide scales, big bold numerals above the scale and divisions for unobstructed reading. Tapered needle-sharp pointers and shadow-free acrylic covers help to pinpoint values. Available in taut band and pivot and jewel types. Gasket sealer gives this panel meter a dust and moisture resistant design. (Except 1 1/2").


Size Input Part Number  
1.5″ DCV 250120 Request A Quote
1.5″ DCA 250100 Request A Quote
1.5″ VAC N/A Request A Quote
1.5″ AAC N/A Request A Quote
2.5″ DCV 250220 Request A Quote
2.5″ DCA 250200 Request A Quote
2.5″ VAC 250244 Request A Quote
2.5″ AAC 250240 Request A Quote
3.5″ DCV 250320 Request A Quote
3.5″ DCA 250300 Request A Quote
3.5″ VAC 250344 Request A Quote
3.5″ AAC 250340 Request A Quote
4.5″ DCV 250420 Request A Quote
4.5″ DCA 250400 Request A Quote
4.5″ VAC 250444 Request A Quote
4.5″ AAC 250440 Request A Quote




Size Input Part Number  
1.5″ DCV 254120 Request A Quote
1.5″ DCA 254100 Request A Quote
1.5″ VAC N/A Request A Quote
1.5″ AAC N/A Request A Quote
2.5″ DCV 254220 Request A Quote
2.5″ DCA 254200 Request A Quote
2.5″ VAC 254244 Request A Quote
2.5″ AAC 254240 Request A Quote
2.5″ Frequency 254250 Request A Quote
3.5″ DCV 254320 Request A Quote
3.5″ DCA 254300 Request A Quote
3.5″ VAC 254344 Request A Quote
3.5″ AAC 254340 Request A Quote
3.5″ Frequency 254350 Request A Quote
4.5″ DCV 254420 Request A Quote
4.5″ DCA 254400 Request A Quote
4.5″ VAC 254444 Request A Quote
4.5″ AAC 254440 Request A Quote
4.5″ Frequency 254450 Request A Quote


New Big Look Taut Band - Model 250

Taut band is a means of suspending the moving mechanism between two ribbons of metal, obviating the need for pivots, jewels and control springs found in conventional mechanisms. The absence of friction resulting from this permits greater sensitivities and provides more rugged meters.Common failures of conventional meters subjected to shock testing are cracked jewels and/or blunted pivots. Taut band, without pivot and jewels, consequently, will withstand shock in excess of that specified for pivot and jewel meters. For example, ANSI Specifications for panel meters require 50G shock. Taut-band meters will withstand 100G shock.

  • New Big Look Taut Band 250 - AC Ammeter
  • New Big Look Taut Band 250 - AC Voltmeter
  • New Big Look Taut Band 250 - DC Ammeter
  • New Big Look Taut Band 250 - DC Voltmeter

New Big Look Pivot & Jewel - Model 254

Pivot & Jewel - In this design the coil and pointer are supported by polished steel pivots at each end which fit into jewel bearings. Pivot and jewel meters are recommended for high- vibration environments because of the mechanism's inherent stability and strength. Accuracy and repeatability are almost equal to the taut-band's, and good performance from the pivot and jewel construction is the reason for its long popularity. Don't specify pivot and jewel meters for applications that involve high shock, but do take advantage of this meter's ability to withstand vibration.

  • New Big Look Pivot & Jewel 254 - AC Ammeter
  • New Big Look Pivot & Jewel 254 - AC Voltmeter
  • New Big Look Pivot & Jewel 254 - DC Ammeter
  • New Big Look Pivot & Jewel 254 - DC Voltmeter
  • New Big Look AC Frequency

Accuracy All DC and AC iron-vane; ±2% of full-scale AC rectifier type; ±3% of full scale (with 60 Hz sine wave at 25º C). When standard 60 Hz iron vane ammeters are used at the extreme limits of 25 or 400 Hz, additional error (approx. .75%) may be experienced. Expanded-scale voltmeters: ±.5% of full scale value.
ANSI Specification
All meters meet ANSI Specifications C-39.1
Overload Ammeters (AC and DC) momentary: 10 times the rated current for 10 consecutive intervals of 0.5 second with a 1 minute interval between successive applications; sustained: 20% for six hours
Voltmeters (AC and DC) - 50% momentary, 20% sustained
Scale Data 90° rotation
Scale Length
Size Length
1 1/2" 1.40"
2 1/2" 2.06"
3 1/2" 2.88"
4 1/2" 3.93"

Insulation Level 1 1/2" -1500 VRMS Hi-pot
All meters (except 1 1/2") 2600 VRMS Hi-pot
Burden Data AC ammeter-5 amps. 0.5 VA max. 0.5 power-factor lagging @60 Hz
AC Voltmeter-unity power factor
Response Time 2.5 seconds (max.) for AC ratings
3 seconds (max.) for 2 1/2", 3 1/2", 4 1/2" size
For microammeters; 2 seconds (max.) for all other DC ratings
Overshoot Max. of 40%
Name Description File Type  
Panel Meter Catalog pdf icon
989 KB
Download
Dim Dwg - 250 Series - 1.5" Model pdf icon
17 KB
Download
Dim Dwg - 250 Series - 2.5" Model pdf icon
19 KB
Download
Dim Dwg - 250, 254 Series - 3.5" Model pdf icon
18 KB
Download
Dim Dwg - 250, 254 Series - 4.5" Model pdf icon
17 KB
Download
 

All Products Guide
All Products Guide
PDF (26.47 MB)
CALL TOLL-FREE AT
1-800-888-6400
(8:00 TO 17:00 EASTERN)
y-Link