Specifications - Model 2016 01

Max. Scale Value 5/10/20/50 mA
Approximate Consumed Current 375 mV
Operating Principle Thermocouple type Class
Class JIS C 1102: 1997 Class 1.0
Operating Position Horizontal
Scale Length Approximately 135 mm (Deflection Angle: 85°)
Scale Divisions 100 for ammeters, 150 for voltmeter
Overload Approximately 1.5 times rated current (or approximate consumed current)
Operating Frequency Range 10 Hz to 5 MHz
Operating Temperature Range 0 ~ 40 ºC
Operating Humidity Range 30 ~ 75% RH
Storage Temperature Range -10 ~ 50 ºC
Storage Humidity Range 25 ~ 80% RH
Linemax 250 V (Ammeters only)
Approx. External Dimension 260 x 180 x 115 mm
Approx. External Weight 2.5 kg
Optional Accessories 2291 01 Carrying case for ammeters
2292 01 Carrying case for voltmeter
B964688 Spare thermocouple

Features

  • Taut-band suspension system eliminates friction and provides good resistance to shock impact.
  • For measurements (DC) up to high frequencies

 

Specifications - Model 2016 02

Max. Scale Value 20/50/100/200 mA
Approximate Consumed Current 375 mV
Operating Principle Thermocouple type Class
Class JIS C 1102: 1997 Class 1.0
Operating Position Horizontal
Scale Length Approximately 135 mm (Deflection Angle: 85°)
Scale Divisions 100 for ammeters, 150 for voltmeter
Overload Approximately 1.5 times rated current (or approximate consumed current)
Operating Frequency Range 10 Hz to 2 MHz
Operating Temperature Range 0 ~ 40 ºC
Operating Humidity Range 30 ~ 75% RH
Storage Temperature Range -10 ~ 50 ºC
Storage Humidity Range 25 ~ 80% RH
Linemax 250 V (Ammeters only)
Approx. External Dimension 260 x 180 x 115 mm
Approx. External Weight 2.5 kg
Optional Accessories 2291 01 Carrying case for ammeters
2292 01 Carrying case for voltmeter
B964688 Spare thermocouple

Features

  • Taut-band suspension system eliminates friction and provides good resistance to shock impact.
  • For measurements (DC) up to high frequencies

 

Specifications - Model 2016 03

Max. Scale Value 100/200/500/1000 mA
Approximate Consumed Current 375 mV
Operating Principle Thermocouple type Class
Class JIS C 1102: 1997 Class 1.0
Operating Position Horizontal
Scale Length Approximately 135 mm (Deflection Angle: 85°)
Scale Divisions 100 for ammeters, 150 for voltmeter
Overload Approximately 1.5 times rated current (or approximate consumed current)
Operating Frequency Range 10 Hz to 1 MHz
Operating Temperature Range 0 ~ 40 ºC
Operating Humidity Range 30 ~ 75% RH
Storage Temperature Range -10 ~ 50 ºC
Storage Humidity Range 25 ~ 80% RH
Linemax 250 V (Ammeters only)
Approx. External Dimension 260 x 180 x 115 mm
Approx. External Weight 2.5 kg
Optional Accessories 2291 01 Carrying case for ammeters
2292 01 Carrying case for voltmeter
B964688 Spare thermocouple

Features

  • Taut-band suspension system eliminates friction and provides good resistance to shock impact.
  • For measurements (DC) up to high frequencies

 

Specifications - Model 2016 04

Max. Scale Value 15/30/75/150 V
Approximate Consumed Current 5 mV (200 Ω/V)
Operating Principle Thermocouple type Class
Class JIS C 1102: 1997 Class 1.0
Operating Position Horizontal
Scale Length Approximately 135 mm (Deflection Angle: 85°)
Scale Divisions 100 for ammeters, 150 for voltmeter
Overload Approximately 1.5 times rated current (or approximate consumed current)
Operating Frequency Range 10 Hz to 1 kHz
Operating Temperature Range 0 ~ 40 ºC
Operating Humidity Range 30 ~ 75% RH
Storage Temperature Range -10 ~ 50 ºC
Storage Humidity Range 25 ~ 80% RH
Linemax 250 V (Ammeters only)
Approx. External Dimension 195 x 170 x 87 mm
Approx. External Weight 1.8 kg
Optional Accessories 2291 01 Carrying case for ammeters
2292 01 Carrying case for voltmeter
B964688 Spare thermocouple

Features

  • Taut-band suspension system eliminates friction and provides good resistance to shock impact.
  • For measurements (DC) up to high frequencies
ModelDescription
2016 015/10/20/50 mA, 375 mV, 10 Hz to 5 MHz, 260 x 180 x 115 mm, 2.5 kg
2016 0220/50/100/200 mA, 375 mV, 10 Hz to 2 MHz, 260 x 180 x 115 mm, 2.5 kg
2016 03100/200/500/1000 mA, 375 mV, 10 Hz to 1 MHz, 260 x 180 x 115 mm, 2.5 kg
2016 0415/30/75/150 V, 5 mV (200 ?/V), 10 Hz to 1 kHz, 195 x 170 x 87 mm, 1.8 kg