Voltage Probes

An oscilloscope is only as good as its probes. Our range includes high voltage, differential, active, low capacitance, and passive types, with ranges to 7kV and frequency bandwidths to 5 GHz.

1 GHz, 50:1, Max. Differential Voltage: ±25 V (DC + ACpeak), Probe Power: dedicated probe interface

500 MHz, 50:1, Max. Differential Voltage:±25 V(DC+ACpeak)
Probe Power:Dedicated probe interface

150 MHz, 500:1/50:1, Max. Differential Voltage: ±1400 V (DC + ACpeak) at 500:1, Probe Power: dedicated probe interface For DLM2000, DLM3000, DLM4000, DLM5000, DL6000, DLM6000, DL9000 and SB5000 series

50 MHz, 1000:1 / 100:1, Max. Differential Voltage: 5000 Vrms and 7000 Vpeak or less
Probe Power : probe power supply

150 MHz, 500:1 / 50:1, Max. Differential Voltage:±1500 V (DC + ACpeak)
Probe Power:probe power supply

500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m Supplied standard with DLM3000, DLM5000 series

200 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.5 m
For DLM2000 (200 MHz model)

500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m
For DLM2000, DLM4000, DL6000, DLM6000 series

10 MHz, 10:1/1:1, 600 V (DC + ACpeak) CAT II, 1.5 m
For ScopeCorder Non-Isolated Modules

400 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m
For DL9000, DL9700/DL9500, SB5000 series

500 MHz, 10:1, 400 Vrms/1250 Vpeak CAT I 300 Vrms CAT II, 1.2 m
For DLM2000, DLM4000, DL6000, DLM6000 series

500 MHz, 10:1, 400 Vrms, 1.3 m
For DLM3000, DLM5000 series

400 MHz, 100:1, 1000 Vrms CAT II 4000 V transient over-voltage CAT I, 1.2 m
For DL1700, DLM2000, DLM3000, DLM4000, DLM5000, DL/6000, DLM6000, DL9000 and SB5000 series

250 MHz, 100:1, 1000 Vrms CAT II 4000 V transient over-voltage CAT I, 3 m
For DL1700, DLM2000, DLM3000, DLM4000, DLM5000, DL/6000, DLM6000, DL9000 and SB5000 series

200 MHz, 10:1, ±1000 V (DC + ACpeak) CAT II, 2.5 m,Wide operating temperature range (−40 to +85°C)
For DLM2000, DLM4000 series.

200 MHz, 10:1, ±1000V (DC + ACpeak) CAT II, 2.5 m
Operating environment: −40 to +85°C (no condensation)
For DLM3000, DLM5000 series.

100 MHz, 10:1, Isolated BNC, 1000 V CAT II, 1.5 m
For ScopeCorder Isolated Modules

200 MHz, 100:1, Isolated BNC, ±1000 V (DC + ACpeak) CAT II ±3540 V (DC + AC peak) CAT I, 1.5 m
For ScopeCorder Isolated Modules

Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series

5 GHz, 20:1 / 10:1, 20 Vrms / 40 VACpeak, 1.1 m, For DLM series

900 MHz, 10:1, ±10 V (DC + ACpeak), 1.5 m, Probe Power: probe power supply

Overview:

After a disastrous 2009, the large publicly held test companies enjoyed booming business in 2010.

Looking for more information on our people, technology and solutions?


Contact Us
Top