AQ6319 Optical Spectrum Analyzer (DISCONTINUED)

Notice: This product was discontinued on Jun 16, 2010. See this replacement product:

The AQ6319 packs the power of cutting-edge technologies with many years of research and experience. It holds the best gratings based monochromator optical performance on the market and provides customers with a user-friendly interface for faster and more accurate measurement. In fact, the AQ6319 raises the standards in the optical testing industry.

With an unprecedented wavelength accuracy of ±10 pm (1520-1580 nm), the AQ6319 OSA has become an outstanding instrument in both general and specialized R&D labs for high accuracy wavelength measurement. Yokogawa keeps the "free-space" design between the incident beam and the monochrometer; this proven technology which is inherited from the world-renowned AQ6317 series OSAs offers much greater facility for researchers using specialty fibers, especially with large core diameters. The new AQ6319 offers a much faster sweep speed than any other models. It also features a LAN connection for faster and easier data transfer, as well as remote control capabilities. In addition, many new analysis functions have been included.
 

  • Ultra high Wavelength Accuracy
    ±10 pm (1520 to 1580 nm)
    ±20 pm (1450 to 1520 nm)
    ±20 pm (1580 to 1620 nm)
    ±50 nm (600 to 1700 nm)
    The above specs are after calibration with a built-in source
  • High Wavelength Linearity
    ±10 pm (1520 to 1580 nm)
    ±20 pm (1450 to 1520 nm)
    ±20 pm (1580 to 1620 nm)
    The above specs are after calibration with a built-in source
  • High Wavelength Resolution
    Provides maximum wavelength resolution at 10 pm
  • High Wavelength Resolution Accuracy
    Provides excellent wavelength resolution accuracy within ±2%
  • Best Optical Performance
    Wide close-in dynamic range:
    70 dB @ ±0.2 nm
    Fast sweep and quick response
  • Versatile Analysis Functions
    Comes with zooming and overview windows
  • Low Polarization Dependency
    Measurements such as gain of the optical amplifier can proceed accurately because polarization dependency is suppressed as low as ±0.05 dB.
  • High Power Measurement
    Max input power: +23 dBm per channel; Max safe input power: +27 dBm
  • Multiple Communication Interface
    GP-IB, LAN, printer, and others
  • Easy Operation with Mouse and Keyboard
  • Large Data Storage and Fast Data Transfer (FTP)

 

Application Note
Overview:

Key Function

Overview:

High Speed Stray Light Reduction Function

Overview:

No, unfortunately due to the number of current fiber combinations, we do not stock optical fibers. There are many companies that specialize in optical fiber cords.

Overview:

If you have products currently in China that require calibration or repair, you may either return them to your local Yokogawa service center or the Yokogawa China Service & Repair Center.   Please be advised that ...

Overview:

Level Accuracy:Level Accuracy is a tolerance to the true value of measured value, when a standard level is measured with a standard wavelength. Level Linearity:Level Linearity is the width of error dispersion ...

Overview:

Wavelength accuracy: Wavelength accuracy is a tolerance to the true value of a measured value when the standard wavelength is measured.  Wavelength repeatability:Wavelength repeatability is the stability of ...

Overview:

The Chopped Light mode is used: To increase measurement level sensitivity by cutting the high frequency noise To detect only the light that the LS emitted, effective for free space measurement. In free space ...

Overview:

Please download the attached application note for instructions on how to make High Bit Rate Modulated OSNR Measurement for the AQ6319 and AQ6370 series Optical Spectrum Analyzer..

Overview:

If you are performing wavelength calibration using the instrument's built-in light source, the warning message is an indication that the monochromator needs to be repaired. Please visit our Contact site to locate ...

Overview:
  • AQ6319 Optical Spectrum Analyzer
  • Warning "142 WL calibration failed"
  • Displayed when light source level is not enough at wavelength calibration or calibration cannot be executed because wavelength difference is out of calibration 

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making

Top