CT60/ CT200/ CT1000/ CT1000A/ CT2000A AC/DC Current Sensor

AC/DC current sensors capable of highly accurate measurement starting in DC range.

CTseries4The AC/DC current sensors allow you to take measurements of large DC and AC currents.
The current output mode makes it possible to connect the AC/DC current sensors to the direct current input terminals of the WT Series Power Analyzers and PX8000 Precision Power Scope for measurements. With a single power meter, you can measure very small currents by direct input and large currents of up to 2000 A using the current sensor (and of up to 1400 A using the 751552 clamp probe). The AC/DC current sensors can be used for large current and power measurements in a wide range of application areas, such as hybrid electric and pure electric vehicles, batteries, inverter motors, energy, railway, and industrial motors.

CT2000A
Current range : 0 to 2000 A (DC), 3000 Apeak (AC)
Wide measurement frequency range: DC to 40 kHz (-3 dB)
Highly-precise basic accuracy: ±(0.05% of rdg + 30 µA)

CT1000A
Current range: 0 to 1000 A (DC), 1500Apeak (AC)
Wide measurement frequency range: DC to 300kHz (-3dB)
Highly-precise basic accuracy: ±(0.04% of rdg + 30µA)

CT1000
Current range : 0 to 1000 A (DC), 1000 Apeak (AC)
Wide measurement frequency range: DC to 300 kHz (-3 dB)
Highly-precise basic accuracy: ±(0.05% of rdg + 30 µA)

CT200
Current range : 0 to 200 A (DC), 200 Apeak (AC)
Wide measurement frequency range: DC to 500 kHz (-3 dB)
Highly-precise basic accuracy: ±(0.05% of rdg + 30 µA)

CT60
Current range : 0 to 60 A (DC), 60 Apeak (AC)
Wide measurement frequency range: DC to 800 kHz (-3 dB)
Highly-precise basic accuracy: ±(0.05% of rdg + 30 µA)

Jas8 Tm Wtacc 10 02

Connection examples* making use of built-in DC power supply (/PD2 option)

DC_power_supply_1

DC_power_supply_2

*1: Use an insulated conductor or cable for wiring on the primary side.
*2: When connected to CT2000A current sensors, use DC power supply option (/PD2) for WT1800E or PX8000.

Combination among CT current sensors, dedicated cables and Shunt Resistor Boxes

DC_power_supply_3

Current limitations of the /PD2 option when using CT2000A

When connecting the current sensor, CT2000A, to the DC power supply option (/PD2) terminals on a WT1800E or PX8000 Power Analyzer, make sure that the output current does not exceed the range shown below.

WT1800E PX8000
(Total current consumption for
 channel 1 through 6) ≤ 6 A
(Total current consumption for
channel 1 through 4) ≤ 4 A

Connection example*
Using external DC power supply

DC_power_supply_4

* Use conductors or cables with reinforced insulation for primary input.
* Make sure that the total load resistance including measuring instrument’s internal resistance and external    load resistance (Rb) is within the specification to prevent oscillation. And confirm the rated power specification of the load resistance.

Overview:

In this application note you will learn when and how to use different methods to connect a current transformer to a power analyzer.

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making

Top