Optical Wavelength Meter

Wavelength Measuring Device

A Michelson interferometer-based optical wavelength meter with high measurement performance and excellent cost performance that meets measurement needs from optical devices to optical transmission equipment.

Types of Wavelength Meters

There are 12 types depending on the combination of wavelength measurement accuracy, wavelength range, and number of detection wavelengths.
Wavelength accuracy (Standard / High accuracy)
Standard: ±0.7ppm (AQ6150B), High accuracy: ±0.2ppm (AQ6151B)
Wavelength range (Standard / Extended / Wide-range)
Standard: Supports optical communication wavelengths of O to L bands
Expansion: Supports wavelengths of CWDM transceivers as wll as the O to L bands
Wide-range: Supports wavelengths of pump lasers as wll as the extended O to L bands
Number of wavelengths (Single wavelength / Multi-wavelength)
Multi-wavelength: simultaneously measures multiple wavelengths such as WDM signals
Single wavelength: measures only a single wavelength such as an output from a wafer or an LD chip

The AQ6150B measures the wavelength and power levels of both CW and Modulated optical signals from transceivers and WDM transmission systems.

  • Wavelength range: 900 to 1700 nm
  • Wavelength accuracy: ±0.7 ppm
  • AQ6151B optical light wavelength meter
  • Wavelength and power level of CW and modulated optical signals from tunable lasers and DWDM transmission systems
  • Range: 900 to 1700 nm
  • Accuracy: ±0.2 ppm

Optical wavelength meter AQ6150B

Single Wavelength Meter
AQ6150B-10-SW
Single Wavelength Meter
AQ6150B-20-SW
Single Wavelength Meter
AQ6150B-30-SW
O to L-band(Standard) O to L-band(Extended) Wide-range

Wavelength range: 1270 to 1650 nm
Wavelength accuracy: ±0.7 ppm
Number of wavelength:1
Min.measurement time: 0.2 s or less

Wavelength range: 1200 to 1700 nm
Wavelength accuracy: ±0.7 ppm
Number of wavelength:1
Min. measurement time: 0.2 s or less

Wavelength range: 900 to 1700 nm
Wavelength accuracy: ±0.7 ppm
Number of wavelength:1
Min. measurement time: 0.2 s or less

 

Multi Wavelength Meter
AQ6150B-10-MW
Multi Wavelength Meter
AQ6150B-20-MW
Multi Wavelength Meter
AQ6150B-30-MW
O to L-band(Standard) O to L-band(Extended) Wide-range

Wavelength range: 1270 to 1650 nm
Wavelength accuracy: ±0.7 ppm
Number of wavelengths:1024 (max.)
Min.measurement time: 0.2 s or less

Wavelength range: 1200 to 1700 nm
Wavelength accuracy: ±0.7 ppm
Number of wavelengths:1024 (max.)
Min. measurement time: 0.2 s or less

Wavelength range: 900 to 1700 nm
Wavelength accuracy: ±0.7 ppm
Number of wavelengths:1024 (max.)
Min. measurement time: 0.2 s or less

 

High accuracy optical wavelength meter AQ6151B

Single Wavelength Meter
AQ6151B-10-SW
Single Wavelength Meter
AQ6151B-20-SW
Single Wavelength Meter
AQ6151B-30-SW
O to L-band(Standard) O to L-band(Extended) Wide-range

Wavelength range: 1270 to 1650 nm
Wavelength accuracy: ±0.2 ppm
Number of wavelength:1
Min.measurement time: 0.2 s or less

Wavelength range: 1200 to 1700 nm
Wavelength accuracy: ±0.2 ppm
Number of wavelength:1
Min. measurement time: 0.2 s or less

Wavelength range: 900 to 1700 nm
Wavelength accuracy: ±0.2 ppm
Number of wavelength:1
Min. measurement time: 0.2 s or less

 

Multi Wavelength Meter
AQ6151B-10-MW
Multi Wavelength Meter
AQ6151B-20-MW
Multi Wavelength Meter
AQ6151B-30-MW
O to L-band(Standard) O to L-band(Extended) Wide-range

Wavelength range: 1270 to 1650 nm
Wavelength accuracy: ±0.2 ppm
Number of wavelengths:1024 (max.)
Min.measurement time: 0.2 s or less

Wavelength range: 1200 to 1700 nm
Wavelength accuracy: ±0.2 ppm
Number of wavelengths:1024 (max.)
Min. measurement time: 0.2 s or less

Wavelength range: 900 to 1700 nm
Wavelength accuracy: ±0.2 ppm
Number of wavelengths:1024 (max.)
Min. measurement time: 0.2 s or less

 

Wavelength Measuring Device Display example

Single Wavelength Meter

Single Wavelength Meter

Multi Wavelength Meter

Multi Wavelength Meter

 

Overview:

This paper describes a compact optical channel monitor and a delayed interferometer having free-space optical elements such as lenses or mirrors, as an application of microoptics. These devices have been developed to be built into dense wavelength division multiplexing (DWDM) transmission systems. These optics use a Gaussian beam which is emitted through single-mode optical fibers and located near the optical axis. This paper explains the optical designs of these devices based on the Gaussian beam's behavior.
SANPEI Yoshihiro*1  SUZUKI Yasuyuki*2   IEMURA Kouki*3   ASANO Junichirou*3


*1Communication and Measurement Business Headquarters, Optical Communication Measurement Development Department

*2Communication and Measurement Business Headquarters, Core Technology Development Department

*3Photonics Business Headquarters, Engineering Department IV

Overview:

After a disastrous 2009, the large publicly held test companies enjoyed booming business in 2010.

Brochures

Product Overviews

    Overview:

    From visible light to telecommunication bands and even up to applications in the 2000nm region, optical testing professionals count on the Yokogawa Test&Measurement optical testing family of products. For decades, these precision-based optical measuring instruments have met and exceeded the needs of many customers’ experimental requirements. Applicable to a range of uses in R&D, manufacturing, and academia, Yokogawa Test&Measurement OSAs, OTDRs, OWMs, modular manufacturing test systems, and more deliver quality, consistency, ease of use, and market leadership for all manner of optical test applications.

Looking for more information on our people, technology and solutions?


Contact Us