The CA71 Portable Calibrator is a small, lightweight, multifunction calibrator by Yokogawa that can simultaneously source and measure voltage, current, resistance, TC, RTD, frequency, and pulse signals with high accuracy. The Handy Calibrator incorporates rotary switches for simple handling. Just open the carrying case cover and connect the cables, and you're ready to take measurements.
General Yokogawa CA71 Specifications:
See resources for more specifications, the Yokogawa CA71 manual, and request a quote for Yokogawa calibrator CA71 price details.
Auto-Step Output Function | n value sent automatically when n/m function selection is selected (two options: approximately 2.5 seconds/step or approximately 5 seconds/step) |
---|---|
Sweep Functions | Sweep time (two options: approximately 16 seconds or approximately 32 seconds) |
Memory Function | 50 value sets (generated and measured values are stored as value sets with the same address (up to 50 value sets can be stored)) |
Measuring Unit Maximum Input | Voltage terminal: 300 V AC Current terminal: 120 mA DC |
Current Terminal Input Protection | Fuses: 125 mA/250 V |
Measuring Unit Ground Voltage | Maximum 300 V AC |
Measurement Display Updating Rate | Approximately once per second |
Serial Interface | Enabled when communication cable (RS232) is connected; sold separately as optional accessory |
Display | Segmented LCD (Approx. 76 mm × 48 mm) |
Backlight | LED backlight; auto-off after one minute (from when LIGHT key is turned on) |
Power Supply | Four AA alkaline batteries, or special AC adapter (sold separately) |
Battery Life | Measurement off, output 5 V DC/10 kO or greater: Approximately 40 hours Simultaneous signal generation/measurement, output 5 V DC/10 kO or greater: Approximately 20 hoursSimultaneous signal generation/measurement, output 20 mA/5 V: Approximately 12 hours (using alkaline batteries, with backlight off) |
Auto-Power-Off Function | Approx. 10 minutes (auto-power-off can be disabled through a DIP switch setting) |
Applicable Standard | EN55011: 1998, Class B, Group 1 EN61326-1: 1997 + A1: 1998 IEC61010-1, IEC61010-2-31 |
Insulation Resistance | Across input terminal and output terminal, 500 V DC, 50 MO or greater |
Withstand Voltage | Across input terminal and output terminal, 3.7 kVAC, for one minute |
Operating Temperature And Humidity Ranges | 0 - 50°C, 20 - 80% RH (no condensation) |
Storage Temperature And Humidity Ranges | -20 - 50°C, 90% RH or less (no condensation) |
External Dimensions | Approx. 190 × 120 × 55 mm |
Weight | Approx. 730 g (including batteries) |
Easy Operation | The Handy Calibrator incorporates rotary switches for simple handling. Just open the carrying case cover and connect the cables, and you're ready to take measurements. |
---|---|
A Wide Array of Useful Functions |
|
Supplied Accessories | CA71/SP1 includes Communications cable, data logging softare, 120V power supply, magnetic backing instrument case, source/measure cables, NIST traceable certification. |
---|---|
Standard Accessories | Carrying case: 93016 Four AA alkaline batteries: A1070EB × 4 Fuse: A1501EF (for current terminal input protection) Measurement lead cables (one red, one black): RD031 Signal generating lead cables (one red, two black): 98020 Terminal adapter: 99021 User’s manual: IM CA71-E |
Optional Accessories (Sold Separately) | AC adapter: 94012 (100 V AC power supply) AC adapter: 94013 (120 V AC power supply) AC adapter: 94016 (220–240 V AC power supply) Accessory carrying case: B9108XA Communication cable: 91017 RJ sensor: B9108WA (For reference junction compensation) |
Spare Parts | Carrying case: 93016 Fuse: A1501EF (for current terminal input protection) Measurement lead cables (one red, one black): RD031 Signal generating lead cables (one red, two black): 98020 Terminal adapter: 99021 |
The communication function of CA71 Communication Software enables users to set output values of the CA71 on a PC. However, the range for generation/measurement should be selected using the rotary switch on the calibrator.
The following operations can be executed while monitoring the CA71 on the PC.
Data Receiving | Memory-mode data or real-time data can be received from the CA71. |
---|---|
Data Transmission | Setting value of generation can be set and sent to the CA71. |
Data Processing | The data can be saved and forwarded to EXCEL. A trend graph is created and shown on the PC screen. |
Date | Version | Contents |
---|---|---|
Sep, 2011 | 1.10b | Ver. 1.10b supports Windows 7 and Excel 2010 |
Dec, 2010 | 1.10a | Trouble in which installation fails with OS other than English was corrected. |
Oct, 2009 | 1.10 | Ver1.10 supports Windows Vista and Excel2007 |
CPU | 300MHz or higher 1GHz or higher (Vista, 7) |
---|---|
OS | Windows XP / Vista (32bit) / 7 (32bit/64bit) |
Required space on the HDD | 10 MB or greater |
Recommended memory capacity |
128 MB or greater 1GB or greater (Vista, 7) |
Serial I/O capability | A serial port conforming to RS-232C standard should be available |
Software | Microsoft Excel 2003 / 2007 / 2010 |
*Windows, Excel are registered trademarks of Microsoft Corporation
The carrying case can hold the source signal and measurement lead cables, terminal adapter, four spare batteries, fuses, AC adapter, and user’s manual.