720256 4-Channel High-Resolution Isolation Module

The Yokogawa 720256-4 is a 4-channel High-Resolution Isolation Module that is capable of 3 MHz of bandwidth at an ultra high 16-bit resolution and ±0.25% accuracy with isolated BNC inputs.

With a sampling rate of 10 MS/s, high noise immunity, low noise, and the ability to deliver 600 V isolated measurements (powered by Yokogawa’s IsoPRO™ isolation technology), the 720256-4 combines accuracy, reliability, and safety in one compact design. 

This module is ideal for testing and long-term monitoring for power generators and multi-output power supplies.
 

Key Features

  • Ultra High Resolution: 10 MS/s sampling with 16-bit resolution delivers accurate waveform capture for high-frequency, high-voltage applications

  • Optically Isolated Channels: Each input channel is optically isolated, providing robust protection against ground loops and common-mode interference while maintaining accurate differential measurements even in high-voltage systems. Using high-speed optical fiber-based transmission, IsoPROTM technology enables 600 V isolated measurements*.

  • Consistent Signal Integrity: Maintains low noise and high accuracy across a wide measurement bandwidth

  • Seamless System Integration: Fully compatible with Yokogawa’s ScopeCorder (DL950) and High-Speed DAQ (SL2000) platforms, the 720256-4 extends system capability without adding setup complexity

  • Testing and Longterm Monitoring: Ideal for power generators and multi-output power supplies. Also provides dynamic analysis of multi-channel data recording applications.

* in combination with the 700929, 702902, or 701947 probes

4CH 10 MS/s, 16-Bit Isolation Module (720256)
Item Specifications
Standard operating conditions Temperature: 23 ±5 °C
Humidity: 20 to 80 % RH
After a 30 minute warm-up and after calibration
Effective measurement range 20 div (display range: 10 div)
Number of input channels 4
Input coupling settings AC, DC, GND
Maximum sample rate 10 MS/s
Input type Isolated unbalanced
Frequency characteristics1 (−3 dB point when a sine wave of amplitude ±3 div is applied) DC to 3 MHz
Voltage scale setting 5 mV/div to 20 V/div (1-2-5 steps) (when using 1:1 probe factor)
Maximum input voltage (at a frequency of 1 kHz or less)
Combined with the 700929 (10:1), 702902 (10:1), or 701947 (100:1)2 600 V (DC+ACpeak)
Combined with the 701901 + 701954 (1:1)4 200 V (DC+ACpeak)
Direct input (cable that does not comply with the safety standards)6 42 V (DC+ACpeak)
Maximum rated voltage to ground – between input and case and between inputs (at a frequency of 1 kHz or less)
Safety standard’s working voltage  
Combined with 700929 (10:1), 702902 (10:1), 701947 (100:1)3 or combined with 701901 + 701954 (1:1)5 300 Vrms CAT II, 400 Vrms (measurement category Other (O), 1500 V transient overvoltage)
Direct input (cable that does not comply with the safety standards)7 42 V (DC+ACpeak) (CAT II, 30 Vrms)
Vertical (voltage) axis accuracy DC accuracy1 ±(0.25% of 10 div)
Input connector BNC connector (isolated type)
Input impedance 1 MΩ ±1 %, approx. 32 pF
−3 dB point when AC coupled 10 Hz or less (1 Hz or less when using the 700929 or 702902, 0.1 Hz or less when using the 701947)
Common mode rejection ratio 80 dB (50/60 Hz) or more (typical value8)
Residual noise level (input section shorted) ±0.05 div 5 mV/div to 20 mV/div (typical value8)
±0.025 div 50 mV/div to 20 V/div (typical value8)
Withstand voltage 2300 Vrms for 2 seconds (across each input terminal and earth) (60 Hz)
Insulation resistance 500 VDC, 10 MΩ or more (across each input terminal and earth)
A/D converter resolution 16 bit (2400 LSB/div)
Temperature coefficient Zero point: ±0.02 % of 10 div/°C 50 mV/div to 20 V/div (typical value8)
               ±0.10 % of 10 div/°C 5 mV/div to 20 mV/div (typical value8)
Gain: ±0.02%/°C (typical value8)
Bandwidth limit Analog filter: Select from Full and 400 kHz
  Cutoff characteristics: −18 dB/OCT (typical value8)
Digital filter: Cutoff frequency: AUTO, 128 kHz, 64 kHz, 32 kHz, 16 kHz, 8 kHz, 4 kHz, 2 kHz, 1 kHz, 500 Hz, 250 Hz, 125 Hz, 62.5 Hz
  Filter format: IIR (except AUTO)
  Cutoff frequency (fc) when set to AUTO
Sample rate Cutoff frequency (fc)
500 kS/s or more 200 kHz
200 kS/s to 100 S/s 40 % of the sample rate
50 S/s or less 40 Hz
Probe attenuation settings Voltage probe: 1:1, 2:1, 5:1, 10:1, 20:1, 50:1, 100:1, 200:1, 500:1, 1000:1, 2000:1, 5000:1, 10 k:1, 20 k:1, 50 k:1
Current probe: 0.1 A:1 V, 0.2 A:1 V, 0.5 A:1 V, 1 A:1 V, 2 A:1 V, 5 A:1 V, 10 A:1 V, 20 A:1 V, 50 A:1 V, 100 A:1 V, 200 A:1 V, 250 A:1 V, 400 A:1 V, 500 A:1 V, 1 kA:1 V, 2 kA:1 V, 5 kA:1 V, 10 kA:1 V, 20 kA:1 V, 50 kA:1 V
Cutoff frequency characteristics of the anti-aliasing filter (AAF) When the filter is set to AUTO, the anti-aliasing filter (AAF) and low-pass filter are automatically set according to the sample rate.
Sample rate AAF Low-pass filter
10 MS/s 200 kHz 400 kHz
5 MS/s 200 kHz 400 kHz
2 MS/s 200 kHz 400 kHz
1 MS/s 200 kHz 400 kHz
500 kS/s 200 kHz 400 kHz
200 kS/s 80 kHz 400 kHz
100 kS/s 40 kHz 400 kHz
50 kS/s 20 kHz 400 kHz
20 kS/s 8 kHz 400 kHz
10 kS/s 4 kHz 400 kHz
5 kS/s 2 kHz 400 kHz
2 kS/s 800 Hz 400 kHz
1 kS/s 400 Hz 400 kHz
500 S/s 200 Hz 400 kHz
200 S/s 80 Hz 400 kHz
100 S/s 40 Hz 400 kHz
50 S/s or less 40 Hz 400 kHz
Ext sample OFF OFF
Wiring / measurement points
Wiring diagram for the numbered measurement points 2 to 7: combined with the 700929, 702902 or 701947 probe; combined with the 701901 + 701954 cable; direct input (cable that does not comply with the safety standards).
 

1. Value measured under standard operating conditions.
8. Typical values represent typical or average values. They are not strictly warranted.
When AC coupled. DC components are not attenuated to 1/10 or 1/100 when the 700929, 702902, or 701947 is in use.

DL950 ScopeCorder

Capture and analyze a wide variety of electromechanical signals and serial buses. High sample rate, long recording times, advanced triggers, and real-time analysis.

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making

Top