The AQ7277B delivers precise, high-resolution reflection analysis for fiber-optic network monitoring and troubleshooting.
Designed for demanding applications in telecommunications operations, maintenance, and aerospace remote sensing, this remote OTDR enables Remote Fiber Test Systems (RFTS), combining robust performance with user-friendly operation.
Pre-integrated compatibility with AQ7933 enables rapid deployment and seamless integration into remote fiber test systems.

The AQ7277B-B01 uses 1650 ± 5 nm, which is suited to maintenance and monitoring of live fiber lines. The AQ7277B-B02 uses 1550 ± 25 nm and offers 50 dB typical dynamic range, making it suitable for testing long-distance fiber links.
The AQ7277B is designed as a compact form factor for embedding into remote test systems. Its dimensions are 230 mm (W) × 50 mm (H) × 140 mm (D) and its weight is approximately 1 kg. Compared to the previous model, its size is reduced by 60%, improving integration into RFTS platforms.
For remote operation and system control, the AQ7277B supports 10BASE-T/100BASE-TX Ethernet and USB 2.0, with status query and LED drive signal alarm outputs available for external system linkage.
| Model | AQ7277B-B01 | AQ7277B-B02 | |
|---|---|---|---|
| Wavelength | 1650±5 nm | 1550±25 nm | |
| Distance range |
0.2, 0.5, 1, 2, 5,
10, 20, 30, 50,
100, 200, 300,
400, 512 km
|
||
| Pulse width |
3, 10, 20, 30, 50,
100, 200, 300, 500,
1000, 2000, 5000,
10000, 20000 ns
|
||
| Sampling resolution | Min. 2 cm | ||
| Dynamic range | 40 dB (typ.) | 50 dB (typ.) | |
| Event dead zone | 0.6 m (typ.) | 0.6 m (typ.) | |
| Attenuation dead zone | 4 m (typ.) | 4 m (typ.) | |
| Distance measurement accuracy |
±0.75 m ± measurement
distance x 2 x 10-5 ± 1 sampling resolution
|
||
| Number of sampling data | Max. 256,000 points | ||
| Remote control interface |
LAN
(10BASE-T/100BASE-TX), USB2.0 (Type B mini)
|
||
| Alarm Output |
Status query,
LED drive signal
|
||
| Environmental Conditions | Operating temperature | -10 to 50 °C | |
| Storage temperature | -20 to 60 °C | ||
| Humidity |
0 to 90% RH
(no condensation)
|
||
| Power requirements | 12 VDC 2.5 A or less | ||
| Dimensions and Weight |
230 mm (W) × 50 mm (H)
× 140 mm (D), Approx. 1 kg
|
||
| Laser safety standards | Class 1 (IEC 60825-1) | ||