The 701927 is a 50:1 or 500:1 high voltage (1400V peak) probe with extended bandwidth covering DC to 150MHz, This probe provides a balanced differential input, to be used with oscilloscopes with single-ended inputs (1 MΩ Input Impedance). This probe works with DLM2000, DLM4000, DL6000, DLM6000, DL9000 and SB5000. This probe is conveniently powered by the Yokogawa Probe Interface I/F.
1400 Vpeak capability is suitable for un-grounded and floating voltage measurements in power electronics and mechatronics applications including inverters, motor drives, and power supplies. 1 m long extension lead pair is included as a standard accessory. Standard pincher tips are exchangeable a wide variety of 4mm safety adapters (sold separately). Reduced size and weight over comparable probes (50% reduced volume over the Yokogawa 700924).
Input type | Balanced differential input |
---|---|
Frequency band | DC TO 150 MHz (-3 dB) |
Input attenuation ratio | 50:1 and 500:1, user selectable |
Input impedance | Approximately 4 MΩ |
Maximum allowed differential voltage | ± 1400 V(DC+ACpeak) (1/500) |
Maximum common mode input voltage | ± 1400 V(DC+ACpeak) or 1000 Vrms |
Common Mode Rejection Ratio (CMRR) | -80 dB (60 Hz), -50 dB (1 MHz) |
Output voltage | ±2.8 V |
Output impedance | Used with 1 MΩ input impedance |
Power Supply | Yokogawa Probe Interface Only |
External dimensions (approximate) | 174 mm x 58 mm x 27 mm |
Total length | Approximately 2.4 meters |
Weight | Approximately 500 grams |
Approved standards |