What is Hi-Resolution Mode?

High Resolution mode can be used to remove high frequency noise and increase vertical resolution. It achieves this by increasing the number of effective bits per data to 12-bits through digital and bandwidth filters. The algorithm it uses to achieve the 12-bits of vertical resolution is:

             Pre-Filter Over-Sample ⇒Average ⇒Data-Thinning ⇒Filter

Please download and review the attached PDF for a comprehensive overview of vertical resolustion and high resolution mode for the DL series oscilloscopes.

Related Products & Solutions

DL7440/DL7480 Digital Oscilloscopes

8-channel 500 MHz oscilloscope with 16 logic inputs, for applications where four channels aren't enough.  Support for eight analog channels, 16 bits with 250MHz logic bandwidth, 16MP of recording memory, power analysis, serial bus analysis, and a broad selection of voltage and current probes.

DL9000 DSO Series

500MHz, 1.0GHz, and 1.5GHz DSOs for debug and high performance applications. 10th
generation oscilloscope from Yokogawa with industry leading 2.5 million wfms/sec and lowest dead time. Winner of Test & Measurement World's "Best in Test" award.

DLM2000 Mixed Signal Oscilloscopes

200, 350, and 500MHz mixed-signal oscilloscopes for every engineer. Best-in-class performance in usability, acquisition, analysis, and display—all at a price you can digest. Options include serial bus, vehicle bus, and power supply analysis functions.

DLM6000 MSO & DSO Series

500MHz, 1.0GHz, and 1.5GHz DSO and MSO models for debug, waveform characterization, bench top, or automated test applications. 4 channel models with 16 or 32 logic inputs. 12th generation oscilloscope with ergonomic physical and on-screen improvements.

SL1000 High Channel Count ScopeCorder

A headless ScopeCorder system capable of connecting multiple chassis into one PC-based system.

 

WE7000 PC-Based Measurement Instruments

One system, multiple instruments:  WE7000 satisfies demands for fast, reliable and precise data acquisition which uses a standard laptop or PC as its user interface. Input modules plug into an expandable measuring station. Via the optical interface, it is possible to galvanically isolate the laptop/PC.

Data Acquisition (DAQ)

Yokogawa data acquisition systems give you the most flexibility and power to measure, display, store, and even actuate any number of physical or electrical phenomena.

High Speed Data Acquisition

  • PC-based, local or remote operation
  • Stream and capture fast transients & complex waveforms
  • Modular, independent channel hardware

Low Speed DAQ & Industrial Recorders

  • Scalable, long-duration data logging
  • Universal inputs (TC/RTD/V) and specialty modules
  • Ideal for design validation, environmental, and facility monitoring
  • Solid state relays outperform switching DMMs

Mixed Signal Oscilloscopes

  • Analyze analog and digital signals simultaneously
  • Advanced triggering and high-speed waveform capture
  • Power analysis, serial bus analysis, & switching loss

Oscilloscopes

  • Digital oscilloscopes
  • High-speed sampling
  • Range of bandwidths for electronic device design and development
  • Advantages of oscilloscope and multi-channel data recorder

ScopeCorders

  • An integrated measurement system for every electromechanical application
  • Modular platform combines oscilloscope and DAQ functionality 
  • Capture high-speed transients and low-speed trends 

Precision Making

Top