OSA: Measurement of Reflection Characteristics of Optical Filters

Download (227 KB)

Characterization of optical filters can be done using an optical spectrum analyzer (OSA) and a broadband light source. The reflection characteristic of the optical filter is obtained as the difference between the reflected light spectrum of the standard reflector** and that of the DUT (reflective optical filter) in case of LOG scale. The measurement light source is selected from wide band light sources such as LED, halogen lamp, ASE, SLD, SC, etc. according to the required optical power and wavelength range.

The applicable models have a free space structure inside the optical input port, and can use large-diameter optical fibers with a core diameter of up to 800 µm. The large fiber delivers more light to the OSA, helping to reduce noise on the measurement waveform and reduce measurement time. However, since the actual minimum wavelength resolution gets lower, it is effective for measurements where the optical power is low and high resolution is not required.

At the time of measurement, be careful not to let stray light (unnecessary irregular reflection light) or ambient light enter the optical coupler. The smaller the numerical aperture (NA) of the optical fiber and the shorter the optical path length from the collimator to the optical coupler, the smaller the loss, which is advantageous for measurement, but high precision adjustment of angle and optical axis is required. Especially the adjustment of the optical coupler side becomes difficult. Therefore, when the optical power is high, it is easier to adjust it by receiving light directly with the ferrule of the optical fiber.

YOKOGAWA offers a variety of OSA in the wavelength range 350-5500 nm that enables measurement of visible (VIS), near-infrared (NIR), short-wave infrared (SWIR), and medium-wave infrared (MWIR) ND filters and bandpass filters.

** If the wavelength dependence of the collimator and optical coupler is sufficiently small and the polarization characteristics and absolute power can be ignored, the standard reflector measurement can be omitted and the output of the broadband light source can be used as the reference spectrum.

OSA: Measurement of Reflection Characteristics of Optical Filters

Related Products & Solutions

AQ6360 Telecom Production Optical Spectrum Analyzer 1200 - 1650 nm

  • AQ6360 optical analyzer
  • Cost-effective optical spectrum analyzer
  • Diffraction grating technology
  • Ideal for optical device manufacturing

AQ6370 Optical Spectrum Analyzer

  • Yokogawa AQ6370 Optical Spectrum Analyzer
  • Re-defining Optical Spectrum Measurement Excellence

AQ6370B Optical Spectrum Analyzer

High performance with a 20 picometer wavelength resolution supporting 25 GHz DWDM spacing and 40G/100G applications, this OSA also supports non-Telecom applications with a wavelength range from 600nm to 1700nm.

AQ6370C Optical Spectrum Analyzer

Popular TELECOM wavelength Range of 600nm to1700nm makes this an ideal model for Telecommunications applications for both singlemode and multi-mode optics.
New for 2010 includes both High Performance and Standard Performance versions.

AQ6370D Telecom Optical Spectrum Analyzer 600 - 1700 nm

  • AQ6370D Optical Spectrum Analyzer
  • Popular TELECOM wavelength Range of 600nm to1700nm
  • Ideal model for Telecommunications applications for single-mode and multi-mode optics

AQ6373B Visible Wavelength Optical Spectrum Analyzer 350 - 1200 nm

  • Dedicated SHORT wavelength Range of 350nm to1200nm
  • Accurately measure visible spectrum of 380nm to 780nm
  • Bio-sciences and beyond
  • Measuring 1064nm Nd:YAG, DPSS Laser sources

AQ6373E Visible Wavelength Optical Spectrum Analyzer 350 - 1200 nm

  • The high-performance optical spectrum analyzer optimized for visible laser measurement
  • 3 models line up for various applications [Standard, High resolution, Limited]
  • Ideal for the lasers of industrial, bio and medical

AQ6374 Wide Range Optical Spectrum Analyzer 350 – 1750 nm

  • AQ6374 Wide Range Optical Spectrum Analyzer
  • Covers wavelengths from 350 to 1750 nm i
  • Visible lights (380 to 780 nm) and telecommunication wavelengths

AQ6374E Wide Wavelength Range Optical Spectrum Analyzer 350 - 1750 nm

  • Wide range optical spectrum analyzer covering from visible light to communications wavelength
  • Wide wavelength range: 350 to 1750 nm
  • Ideal for various applications including fiber

AQ6375B Long Wavelength Optical Spectrum Analyzer 1200 - 2400 nm

High Performance LONG WAVELENGTH
The AQ6375B is a bench-top optical spectrum analyzer covering the long wavelengths, 1200 to 2400 nm, with the added benefits of gas purging input ports / output ports, a built-in cut filter for high order diffracted light, and a novel double speed mode which increases the sweep speed up to 2 times compared to the standard sweep mode.

AQ6375E Long Wavelength Optical Spectrum Analyzer 1200 to 2400 nm and 1000 to 2500 nm

High Performance LONG WAVELENGTH
The AQ6375E covers not only telecommunication wavelengths, but also the SWIR region which is often used for environmental sensing and medical applications.
・Lineup of 3 models [Standard, Extended and Limited]
・Covers wavelengths
     1200 to 2400 nm [Standard, and Limited]
     1000 to 2500 nm [Extended ]

AQ6376 Three Micron Optical Spectrum Analyzer 1500 - 3400 nm

MWIR WAVELENGTH with internal gas purge and cut filter
The AQ6376 is the latest version of our bench-top optical spectrum analyzer extending the wavelength coverage well beyond the NIR range of our previous models into the MWIR region from 1500 to 3400 nm.
Popular applications include the detection of gases such as carbon oxides (COx), nitrogen oxides (NOx), and hydrocarbon gas (CxHy) for environmental studies.

AQ6376E Three Micron Optical Spectrum Analyzer 1500 - 3400 nm

MWIR WAVELENGTH with internal gas purge and cut filter
The AQ6376E is the latest version of our bench-top optical spectrum analyzer extending the wavelength coverage well beyond the NIR range of our previous models into the MWIR region from 1500 to 3400 nm.
Popular applications include the detection of gases such as carbon oxides (COx), nitrogen oxides (NOx), and hydrocarbon gas (CxHy) for environmental studies.

AQ6377 Optical Spectrum Analyzer 1900 - 5500 nm

  • AQ6377 long-wavelength optical spectrum analyzer model covering the MWIR region over 5 μm
  • AQ6370D optical analyzer model with highest resolution (up to 20 pm)
  • Highest close-in dynamic (up to 78 dB)
  • Widest measurement power (up to 110 dB)

Long Wavelength Optical Spectrum Analyzer AQ6375

Unique LONG wavelength range of 1200 to 2400 nm makes this the world's first and only OSA specifically designed for use in advance applications such as Carbon Monoxide (CO), Carbon Dioxide (CO2) gas detection and LIDAR.

Visible Wavelength Optical Spectrum Analyzer AQ6373

Dedicated SHORT wavelength Range of 350nm to1200nm allows this model to accurately measure the visible spectrum of 380nm to 780nm for bio-sciences and beyond. It is also a popular tool for measuring 1064nm Nd:YAG, DPSS Laser sources.

Optical Spectrum Analyzer

  • Optical Spectrum Analyzer to measure and display power distribution of an optical source
  • Optical analyzer trace displays power in vertical scale and wavelength in horizontal scale

Optical Test Equipment

  • Yokogawa optical test equipment solutions to measure optical components/systems
  • Serves demand for high capacity fiber lines and new component technologies

Precision Making