SL2000 High-Speed Data Acquisition Unit

The SL2000 high-speed data acquisition unit is an isolated oscilloscope/High-speed DAQ for embedded systems.

The same plug-in modules as the DL950 and DL350 can be used.
With just one SL2000 unit, you can simultaneously record isolated analog signals from low voltage to 1000V, digital signals, encoder signals, CAN/CAN FD/LIN/SENT communication signals from in-vehicle networks, and NVH signals such as vibration, strain, and temperature.

  • Up to 200 MS/s
  • Isolated 1000 V input, up to 7000 V input with differential probe
  • Up to 8 G point memory
  • Up to 160 CH* (5 units connected and synchronized)
    * Up to 640 channels when using the 720221 16 channel module
  • 10 Gbps PC streaming
  • Real-time calculation/power calculation/motor dq analysis

Embedded System Design

The SL2000 is a 4U-high isolated oscilloscope/High-speed DAQ for system integration that allows the DL950 to be mounted in a system rack.

By combining plug-in modules, it is possible to perform long-term multi-channel recording of voltage, current, temperature, acceleration, strain, pulse, digital, and CAN/CAN FD/LIN/SENT communication signals.

Embedded System Design

 

Up to 160 channels
(4 CH Module, 5-unit Synchronized Connection /C50 Option)

Capture signals at speeds up to 200 MS/s, and scale to 160 channels by linking as many as five synchronized units.

Up to 160 channels

 

Real-time math function, Power math function, Motor dq analysis function
(/G03, /G05, /MT1 option)

Real-time waveform calculation, power calculation, and motor dq analysis are supported-including trigger conditions based on computed results.

Real-time math function, Power math function, Motor dq analysis function

 

Plugin Modules for ScopeCorder

A variety of plug-in modules are available to measure signals such as voltage, temperature, acceleration, strain, and CAN bus data.

Plugin Modules for ScopeCorder

 

Control Software Suitable for Long- Term Recording

IS8000 makes it easy to configure instruments and recording settings for standardized and long duration tests-without the need for complex programming.

Control Software Suitable for Long-
Term Recording

 

Two operation modes: oscilloscope and recorder

There are two modes, "Scope Mode" and "Memory Recorder Mode", to suit the environment and purpose.

Scope Mode

  • This is an operation mode suitable for measuring high-speed signals and repetitive waveforms.
  • Like an oscilloscope, the waveform is recorded each time a trigger occurs according to the set time axis setting (T/Div) and number of sampling points.
  • The measurement range is displayed in scale units (V/Div).

Memory Recorder Mode

  • This is an operation mode suitable for measuring continuous waveforms over long periods of time.
  • Like a data logger or recorder, it performs one-shot measurements with predefined measurement conditions, and records input signals by setting the sampling interval and recording time.
  • The measurement range is displayed relative to the full width (upper and lower limits).

 

Maximum 200 MS/s, isolated 1000 V input. Up to 7000 V possible with differential probe

High-speed sampling of up to 200 MS/s 14 bits is possible, allowing you to accurately capture switching waveforms of high-speed inverters and rapid noise around power supplies.
In addition, when combined with a large-capacity memory of up to 8 G points, you can record continuously for up to 20 seconds even at high-speed sampling of 200 MS/s.

  • The 720212 can provide isolated 1000V input when combined with the 700929 (10:1) /702902 (10:1) /701947 (100:1) passive probes.
  • The 701255 High-Speed ​​10MS/s 12-Bit Non-Isolated Module or Isolated Module can be combined with the 701905 Conversion Cable and 701977 High-Voltage Differential Probe to measure high voltages up to 7000V.

 

Action on trigger and GO/NO-GO judgement

The Action on Trigger function automatically performs predefined tasks-such as saving data files, activating a buzzer, or sending email notifications-when a trigger condition is met. Additionally, it can perform pass/fail (GO/NO-GO) evaluations based on waveform parameters such as shape or amplitude, and execute actions based on the result.

8 G points large memory (/M2 option)

With up to 8 G points of memory and 20 seconds of continuous capturing, even at 200 MS/s, no signal changes are missed.

*Up to 4 G points of memory is allocated per channel.

8 G points large memory (/M2 option)

 

SSD recording (/ST1 or /ST2 option)

The 512 GB internal SSD can record for long periods of time at up to 2 MS/s. Waveforms from dual capture can also be recorded, which is useful for in-vehicle endurance testing and capturing rare spontaneous events.

SSD recording (/ST1 or /ST2 option)

 

Flash acquisition (/ST2 option)

Long time recording at up to 20 MS/s, which is 100 times faster than the previous model, is available. You can capture data anywhere you cannot bring a PC such as on-vehicle or field testing. The flash memory is non-volatile, so the captured data stays in the instrument even after turning off the power. Data can later be transfered to a PC.

Flash acquisition (/ST2 option)

 

Multi-sample rates

Sample rates can be set by channel. Reducing the sample rate reduces the amount of data even when modules with high and low sample rates are mixed together. This allows for less memory space to be used and improves the transfer speed.

Multi-sample rates

 

Available Data Storage

• Built-in SSD 512 GB
• SD Memory Card (SD/SDHC/SDXC)

• USB Storage up to 8 TB
• Network Drive

 

2-motor/4-motor system test for EV

In Hybrid Electric Vehicle (HEV) development, two or four motor systems, with each motor connected to a driving wheel, are commonly used. This design eliminates traditional powertrains, simplifying the overall system and alleviating concerns when driving a 4WD on snowy roads. The multi-channel, high-speed, isolated DL950 can simultaneously capture and analyze signals from these multi-motor setups.

2-motor/4-motor system test for EV

 

Distributed energy resource test (renewable energy)

Renewable energy sources like hydro, solar, and wind power are integrated into the power grid, driving the transition to a sustainable society. The DL950/SL2000 supports this transition with its long-term power recording and analysis capabilities. For example, wind turbines require synchronized monitoring of power generation efficiency at multiple locations, which can be achieved with high precision using GPS or IRIG signals.
Additionally, the DC/AC conversion efficiency of solar panel-generated DC power can be accurately measured using the WT5000 precision power analyzer, while the waveform data from the DL950/SL2000 can be seamlessly integrated with the WT5000’s measurement data to provide a comprehensive analysis of inverter performance.

Distributed energy resource test (renewable energy)

 

Vibration and Acoustic Analysis

Vibration is inherent to "moving objects" such as motors and engines. Analyzing the frequency of vibrations to identify abnormal areas is an essential test in the development of "moving objects." By using multiple acceleration modules, Vibrations at multiple points can be simultaneously captured and up to eight vibration frequencies can be analyzed using FFT functionality to identify faulty components.

Vibration and Acoustic Analysis

Vibration and Acoustic Analysis

 

Railway Vehicle Running Test

By using the DL950 and SL2000, we can simultaneously record the voltage, current, and rotational speed of the battery, inverter, and drive motor, as well as the vibration and interior temperature of railway vehicles.

  • Simultaneous measurement of remote devices with a synchronization accuracy of ±150 ns (typ) when using the /C40 option.
  • Distributed synchronous measurement with up to 160 channels
  • Simultaneous recording of strain and sound (using voltage output microphones or sound level meters) is also possible
  • Using power calculations and motor dq analysis, power efficiency and motor performance can be evaluated.

Railway Vehicle Running Test

 

Vehicle Serial Bus Data Recording and Driving Trajectory Display

You can simultaneously view the trends of physical values from CAN/CAN FD bus data alongside the corresponding measured waveforms on the same screen. For example, you can verify the correlation between the ON/OFF signal of the ignition switch, the corresponding CAN/CAN FD signal, and the actual signals from related pressure sensors, all on the same screen. By connecting a GPS unit, Latitude, longitude, altitude, speed, direction, and time information can be added to the measurement data. Using DIAdem, you can simultaneously display the measurement data and driving position. With IoT gateways or M2M routers, remote control and data monitoring can be performed wirelessly.

Vehicle Serial Bus Data Recording andDriving Trajectory Display

 

Interface

Interface

Interface

Interface

 

ScopeCorder SDK (Software Development Kit)

This software offers an API (Application Programming Interface) for waveform data acquisition with DL950/SL2000, the API is provided as a Dynamic Link Library (DLL). By integrating this DLL into your custom application, you can easily leverage the API for automated measurements via PC control. It supports four key operations:

Free Run Mode:
Continuously acquires data from the start to the stop of the waveform capture.
Trigger Mode:
Captures waveforms based on a specified trigger event.
Flash Acquisition Data Access Library Functionality: Transfers recorded flash acquisition waveforms from the DL950/SL2000 to a PC.

File Operation and Transfer Functionality:
Transfers recorded waveforms from the DL950/SL2000 to a PC.

ScopeCorder SDK (Software Development Kit) This

 

Integrated measurement software platform IS8000

The IS8000 enables synchronized measurements with DL950s, Yokogawa power meters, other manufacturers’ high-speed cameras, and other equipment. It supports measurement setting, remote monitoring, comparative analysis, and MDF file saving to reduce test system development time.

Integrated measurement software platform IS8000

 

IS8002CDV Classic Data Viewer

IS8002CDV is the successor to the data viewer software Xviewer, and enables remote operation of measuring instruments, data file transfer, waveform display, zooming, automatic measurement of waveform parameters, waveform calculation (optional), data format conversion, and more.

IS8022 Classic Data Viewer

 

System development tools

  • Waveform data (WDF) file access library
  • MATLAB WDF Access Toolbox
  • Binary data file format conversion tool
  • Communication command line tool DL-Term
  • Communication library "TMCTL"
  • USB driver
  • LabVIEW driver
  • Sample program (sample programs for various programming languages ​​such as C and Python are available)

720212 High-speed 200 MS/s 14-Bit Isolation Module

  • 720212 High-speed 200 MS/s 14-Bit Isolation Module
  • Max. sampling rate: 200 MS/s
  • A/D conversion resolution: 14-Bit
  • Max. input voltage (DC + ACpeak): 1000V / 200V

720211 High-Speed 100 M/s, 12-Bit Isolation Module

High-Speed 100 MS/s 12-Bit Isolation Module (2 channels) 
IsoPRO technology enables 1kV isolated measurements in combination with 700929 or 701947 probe and is designed for inverter / IGBT related applications in mind. Using high speed optical fiber-based transmission, the module achieves high speed ADC clock and data isolation and provides the performance needed to develop high efficiency inverters, which employ high voltages, large currents, and ever increasing switching speeds.
Applicable to DL350, DL850 series, DL950 and SL1000.

720250 Voltage Module 10MS/s

  • 720250 Voltage Module
  • 10 MS/s sample rate
  • 12-bit resolution
  • 3 MHz bandwidth
  • 2 isolated channels
  • DL350, DL850, DL950, SL1000

701251 Analog Voltage Input Module

  • 701251 Analog Input Module
  • High-Speed 1 Ms/s 16-Bit Isolation Module (2 ch)
  • High sensitivity range (10 mV), low noise (±100 µVtyp), high noise immunity
  • DL850, DL750, SL1000

720256 4-CH 10 MS/s 16-Bit Isolation Module

High-speed 10 MS/s 16-Bit isolation module (4 channels) – High noise immunity. Suitable for testing and longterm monitoring for power generators and multi-output power supplies. Provides dynamic analysis of multi-channel data recording applications. For use with the DL950 ScopeCorder.

Max. sampling rate:  10 MS/s
A/D conversion resolution:  16 bit
Number of channels:  4
Max. input voltage (DC + ACpeak):  600V / 200V

720254 4-CH 1M/s 16-Bit Isolation Module

  • High-Speed 1 MS/s 16-bit Isolation Module (4 ch) 
  • High Noise Immunity  
  • Monitor/test power generator/multi-output power supplies 
  • Dynamic multi-channel data recording analysis
  • DL350 and DL850 series

701255 Analog Voltage Input Module

High-Speed 10 MS/s 12-Bit non-isolation Module (2 ch)
Non-Isolation version of model 720250
Applicable to DL350, DL850 series, DL950 and SL1000.

720268 High Voltage Module 1MS/s

  • 720268 High Voltage Power Supply Module
  • 300 kHz bandwidth
  • 2 isolated channels
  • Max input (DC+ACpeak) 1000V
  • DC accuracy ±0.25%,
  • DL350, DL850, DL950, SL1000

720220 16 Channel Voltage Input Module

  • 16 Channel Voltage Input Module
  • Isolated (GND-terminal)
  • Non-Isolated (CH-CH) 
  • Max allowable voltage between sub-channel high inputs 42V (DC + AC Peak)
  • Applicable to DL350 and DL850 series

701261 Universal Voltage & Temperature Input Module

  • 701261 Universal Module (2 ch)
  • Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel)
  • Applicable to DL350, DL850 series, DL950 and SL1000.

701262 Universal Voltage & Temperature Input Module (w/AAF)

  • Universal Module (with Anti-Aliasing Filter, 2 ch)
  • Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), with AAF
  • DL350, DL850 series, DL950 and SL1000

701265 High-Precision Temperature Input Module

Temperature/high-precision voltage Module (2 ch)
Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (1 mV), and low noise (±4 µVtyp)
Applicable to DL350, DL850 series, DL950 and SL1000.

720266 High-Sensitivity, Low-Noise, Voltage, Temperature Module

  • The 720266 Temperature Module/Voltage Module
  • 16-Bit, 125 S/s (Voltage) and 125 S/s (Temperature) sample rate
  • DL350, DL850 series, DL950, SL1000

720221 16-CH Temperature/Voltage Input Module

  • 16 Channel Voltage/Temperature Input Module
  • To be used with 701953 Scanner Box
  • Applicable to DL350 and DL850 series
  • Voltage/Temperature Conversion

701953 16-CH Scanner Box

  • External scanner box for 720221 module
  • Voltage or temperature measurement (scanner method)
  • Thermocouple (K, E, J, T, L, U, N, R, S, B, W, Au-Fe-chromel)

701270 Strain Input Module (NDIS)

  • Strain Module, NDIS (2 channels)
  • 701955 or 701956 NDIS bridge head
  • Detect/display mechanical stress with ScopeCorder
  • DL350, DL850 series, DL950, SL1000

701271 Strain Input Module (DSUB)

Strain Module with Shunt Calibration, type DSUB (2 channels) to be used in combination with 701957 or 701958 DSUB bridge head.
Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.
Applicable to DL350, DL850 series, DL950 and SL1000.

701275 Acceleration & Voltage Input Module (w/AAF)

  • 2 channel Voltage Module/Acceleration Module
  • Anti-Aliasing Filter 
  • Direct input from built-in amp type acceleration sensor to measure acceleration 
  • DL350, DL850 series, DL950 and SL1000.

720281 Frequency Module

  • 720281 Frequency Module
  • 1 MS/s sample rate 16-bit resolution
  • 2 isolated channels
  • 420 V*2, 42 V*3 max input voltage
  • ±0.1% DC accuracy
  • 0.01 Hz to 500 kHz measurement frequency

720230 Logic Input Module

  • 720230 Logic Input Module
  • Display input logic signals as waveforms at 10 MS/s sampling resolution
  • Single module can observe 16-bit logic signals 
  • 700986, 700987, 702911, 702912 logic probe
  • DL350, DL850, DL950

720245 CAN FD/LIN Monitor Module

  • CAN FD/LIN Monitor Module
  • Decode the CAN FD/LIN-Bus signals, display information on physical data as analog waveforms, compare with sensor data.
  • DL950 (/VCE option) ,DL350 (/VE option) ScopeCorder Vehicle Edition

720243 SENT Monitor Module

Use the SENT monitoring module to decode the SENT protocol signal and display information on physical quantities from SENT output sensors.
Applicable to DL850V & DL850EV, DL350 (/VE option), DL950 (/VCE option) ScopeCorder Vehicle Edition only.

720242 CAN/CAN FD Monitor Module

  • CAN/CAN FD Monitor Module
  • Decode the CAN/CAN FD-Bus signals, display information on physical data as analog waveforms, compare with sensor data
  • DL850V & DL850EV, DL350 (/VE option), DL950 (/VCE option) ScopeCorder Vehicle Edition

720241 CAN/LIN Bus Monitor Module

  • 720241 CAN/LIN bus monitor module
  • Decode CAN or LIN-Bus signals
  • Display physical data as analog waveforms
  • DL850V & DL850EV, DL350 (/VE option), DL950 (/VCE option) ScopeCorder Vehicle Edition

701947 Isolated Probe 1000V / 200 MHz

  • 1.5m Isolated Probe (ScopeCorder)
  • DC to 200 MHz bandwidth 
  • 100:1 attenuation Isolated
  • BNC connector type 
  • For ScopeCorder Isolated Modules

702902 Isolated Passive Probe 1000V / 60 MHz

Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series

700929 Isolated Passive Probe 1000V / 100 MHz

  • Versatile 700929 passive oscilloscope probe
  • 100MHz frequency bandwidth
  • Isolated input module of ScopeCorder series
  • For use with isolated BNC inputs

701940 Passive Probe 600V / 10 MHz

  • 701940 Passive Probe
  • 10 MHz, 10:1/1:1, 600 V (DC + ACpeak) CAT II, 1.5 m
  • For ScopeCorder Non-Isolated Modules

701977 Differential Probe 7000 V / 50 MHz

  • 701977 Differential Probe for Oscilloscope 7000 V / 50 MHz
  • 50 MHz, 1000:1 / 100:1, Max.
  • Differential Voltage: 5000 Vrms and 7000 Vpeak or less

701978 Differential Probe 1500 V / 150 MHz

  • 701978 Differential Probe for Oscilloscope 
  • 1500 V / 150 MHz
  • 500:1 / 50:1
  • Max. Differential Voltage:±1500 V (DC + ACpeak)

701905 Conversion Cable

701905 Conversion Cable for Differential Probe

701917 Current Probe 50 MHz / 5 ARMS

  • 701917 oscilloscope current probe
  • Frequency bandwidth: DC to 50 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

701918 Current Probe 120 MHz / 5 ARMS

  • Yokogawa 701918 Current Probe
  • Frequency bandwidth: DC to 120 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

701930 Current Probe 10 MHz / 150 ARMS

  • 701930 Current Probe 10 MHz / 150 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701931 Current Probe 2 MHz / 500 ARMS

  • 701931 Current Probe 2 MHz / 500 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701932 Current Probe 100 MHz / 30 ARMS

  • 701932 Current Probe 100 MHz / 30 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders, or external power supply

701933 Current Probe 50 MHz / 30 ARMS

  • 701933 50 by 30 current probe
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

702915 Current Probe 50 MHz/ 0.5 ARMS, 5 ARMS, 30 ARMS

  • 702915 Current Probe
  • Freq bandwidth: DC to 50 MHz
  • Maxi continuous input range: 0.5 Arms/ 5 Arms/ 30 Arms
  • Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

702916 Current Probe 120 MHz/ 0.5 ARMS, 5 ARMS, 30 ARMS

Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 0.5 Arms/5 Arms/30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments

720930 Clamp on Probe

The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 50 A
  • 40 Hz to 3.5 kHz Bandwidth

720931 Clamp on Probe

The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 200 A
  • 40 Hz to 3.5 kHz Bandwidth

AC/DC Split Core Current Sensor CT1000S

Industry leading high precision, high current AC/DC split core measurement. Compatible with power analyzers and waveform measurement instruments.

701934 External Probe Power Supply

  • 701934 External Probe Power Supply
  • Power supply for current probes, FET probes, and differential probes
  • Supplies power for up to four probes, including large current probes

701901 BNC to Safety Banana 1.8m Cable, 1:1

  • 701901 BNC to Safety Banana 1.8m Cable, 1:1
  • 1000 Vrms-CAT II, 1.8 m long
  • Safety BNC(male) to safety banana(female)
  • 701959, 701954, 758921, 758922, 758929

701904 1 to 1 Safety Adapter Lead

1:1 Safety Adapter Lead for the 720268 High Voltage Input Module

758928 Pinchers tip (Hook type)

1000 Vrms CAT III, 1 set each of red and black
Equivalent to B9852MM (Color Black)
Equivalent to B9852NM (Color Red)

701954 Large Alligator Clip (dolphin type)

Set contains one black and one red clip.
1000 Vrms-CAT II.

758929 Large Alligator Clip Adapter 1000V

  • Yokogawa 758929 Alligator Clip Adapter 
  • Rated at 1000V
  • Attaches to 758917 test leads
  • Sold in pairs black/red

758922 Small Alligator-Clip Adapter 300V

Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.

758921 Fork terminal adapter

  • 758921 Fork Terminal Adapters
  • For fitting a 4mm banana plug to a fork terminal
  • One black and one red clip
  • 1000 Vrms-CAT II

366926 BNC to Alligator 1m Cable, 1:1

  • 1 m long BNC to alligator clip cable
  • Only for circuits with voltage levels no greater than 42 V
  • Applicable for DL750/DL750P, SL1000 & SL1400

366961 Banana to Alligator 1.2m Cable, 1:1

A subassembly of 1.2 m long test leads with alligator-clip adapters.
Use only for circuits having voltage levels no greater than 42 V.
Applicable for SL1000 & SL1400.

701955/701956 NDIS Bridge Heads 120Ω/350Ω

  • ScopeCorder Accessories for DL850 series, DL750/DL750P, SL1000 & SL1400
  • 701955 NDIS Bridge Head, Bridge resistance: 120Ω , 5m NDIS cable included
  • 701956 NDIS Bridge Head, Bridge resistance: 350Ω , 5m NDIS cable included

701957/701958 D-Sub Bridge Heads 120Ω/350Ω

  • 701957 and 701958 D-SUB Bridge Head
  • Shunt calibration
  • 5m DSUB cable included
  • Bridge resistance:  120Ω 
  • Bridge resistance:  350Ω 

758924 BNC to Banana Conversion Adapter

For conversion between BNC and female banana plug
Applicable for DL750/DL750P, SL1000 & SL1400.

702911-702912 Logic Probe

8-bit, non-isolated, response speed: 3µs or less, treshold level approx 1.4V
702911: 1 meter cable, 702912: 3 meter cable

700986 Logic Probe

8-bit, non-isolated, response speed: 1µs, threshold level approx 1.4V
Two measurement leads (B9879PX and B9879KX) included.

700987 Logic Probe - Isolated Inputs

  • 700987 Logic Probe - Isolated Inputs
  • 8-bit, isolated, response speed: 1ms or less (DC), 20ms or less (AC), threshold level 6VDC, or 50VAC.
  • 758917 and 758922, 758929, 701954 

758917 Measurement Lead Set

  • Set of 0.8m long red and black test leads
  • Used with Power Analyzers and DMMs
  • Used in combination with a pair of optional 758922 or 758929 alligator-clip adapters
  • 1000 Vrms, 32 Arms CAT II

758933 Measurement lead

2 pieces (red and black) in 1 set
length: 1.00 m
Used in combination with the 701959, 758921, 758922, or 758929
Rating: 1000 V CAT III/19 A

701902/701903 Safety BNC to BNC Cable 1m/2m

  • 701902/701903 Safety BNC to BNC Cable for oscilloscope
  • Safe, high-voltage measurements with DL350, DL950, and SL1000 isolated input modules 
  • 701902: 1000 Vtms-CAT II (BNC-BNC), 1 m
  • 701903: 1000 Vrms-CAT II (BNC-BNC), 2 m

701948 Extension Clip Accessories

Connected to the 700929, 701947
Maximum input voltage: 1,000V (DC + ACpeak)
Length: 0.26m/0.3m/0.4m
Applicable for DL750/DL750P, SL1000, SL1400

701906 Long Test Clip

Set contains one black and one red clip
1000 Vrms-CAT II
2 pieces (red and black) in 1 set 
Connected to the 758933, 758917, or 701901
Length: 0.3m
Applicable for DL750/DL750P, SL1000, SL1400

B8099NM 4mm conversion adapter

For 702902, 702906

705926 Connection Cable for DA4, DA12, Scanner Box (701953)

Applicable for DL850 and WT300 series.

705927 Connecting cables

Connecting cable for 701953 (3 m)

A1002JC NDIS Connector for 701270

  • Yokogawa Oscilloscope and ScopeCorder products
  • A1002JC NDIS connector
  • Direct connection to strain module 701270

366924 BNC to BNC 1m Cable

  • 366924 BNC to BNC cable for oscilloscope 
  • 1m BNC wire
  • Simultaneous measurement with 2 units
  • Input external trigger signal

366925 BNC to BNC 2m Cable

BNC-BNC 2m. For connection to simultaneously measurement with 2 units, or for input external trigger signal.

A1800JD Terminal

For 720220 input terminal, one (1) piece

701919 Probe Stand

  • 701919 oscilloscope probe stand
  • Flexible arm, heavy base to hold and stabilize 8-13mm probes
  • Can simplify circuit board testing

720942 Optical Fiber Cord Multi mode optical fiber (LC-LC/3 m)

For DL950,SL2000 multi-unit connection, 3 m

720940 GPS Unit

For DL950,SL2000,DL350

B8059GG Soft case

Soft Case for Accessories

751542-J4 Rack mounting kit

RACK MOUNTING KIT For an JIS-compliant Single-housing Rack

751542-E4 Rack mounting kit

RACK MOUNTING KIT For an EIA-compliant Single-housing Rack

Overview:

Maximum power point tracking (MPPT) charge controllers play a crucial role in the optimization of renewable energy system efficiency and performance. Through dynamic tracking of a renewable energy source’s maximum power point, an MPPT controller enables more efficient energy harvesting, faster charging, and adaptability to changing environmental conditions.

Industries:
Overview:
  • DL950
  • Evaluating and designing the Electric Power Steering (EPS)
  • Multi-channel simultaneous measurement
  • Real-time calculation
Industries:
Overview:

DL950_Comprehensive_evaluation_of_vehicle_systems_using_real_signal

Industries:
Overview:

DL950_Evaluation_of_ECU_and_InverterMotor

Overview:
  • IS8000 Integrated Software Platform
  • Measure current waveform using oscilloscope

Product Overviews

    Overview:

    This video overview of the IS8000 Integrated Software Platform showcases how our integrated solution accelerates engineering workflow and provides a visual tour of this software that tightly integrates timing, control, and data collection from multiple test and measurement instruments.

    Overview:

    Test and measurement engineering work groups can have differing priorities and requirements, which often results in multiple instrumentation systems and data file formats, as well as incompatible reporting. This lack of effective communication between groups and instruments causes decreased efficiency and quality and increased spending and time to market. Unify test and measurement instrumentation, software, and data across engineering teams with a suite of solutions that caters to the different needs of engineering work groups, including accurate power data, fast sampling rates, long recordings of multiple different input types, and insights into waveform data.

    Product Overview

How-tos

    Overview:

    Looking for a turnkey high-speed data transfer solution with better bandwidth and minimal manual overhead?

    The 10Gb Ethernet option on the Yokogawa Test&Measurement DL950 ScopeCorder fits that very role and makes capturing and recording high-speed data seamless and convenient.

    Record data at 50 times the speeds of traditional Ethernet and USB connections and automatically transfer data to your PC in a single step using the IS8000 Integrated Software Platform.

    Overview:

    CAN Bus communication is widely used in the transportation industry where reliable transmission of data is paramount. Monitoring and recording these communications can be easier when using the proper instruments. In this video, a Yokogawa Test&Measurement Applications Engineer demonstrates how to setup the DL950 ScopeCorder to read the temperature of a motor drive alongside its voltage and current output.

    Overview:

    The multi-unit synchronization option for the Yokogawa Test&Measurement DL950 ScopeCorder lets you time synchronize up to five DL950 ScopeCorders, for up to 160 channels of voltage, current, temperature, strain measurements, and more. This video walks you through how to set up and connect the multiple DL950 ScopeCorders, take measurements, and pull the data from all of the instruments for analysis with the IS8000 Integrated Test and Measurement Software Platform.

    Overview:

    Having multiple memory options allows engineering groups to optimize how data is stored, no matter if you need to record for a long time at slower sampling rates, do a fast capture at high sampling rates, or anything in between.

    The Yokogawa Test&Measurement DL950 ScopeCorder operates as an oscilloscope and incorporates the ability to record data for long periods of time like a data acquisition recorder. There are four memory types on the DL950 ScopeCorder: internal memory, solid state drive, flash memory, and PC storage through the IS8000 Integrated Test and Measurement Software Platform. This videos talks about the advantages of each of these and how to pick the best data recording method for you.

Webinars

    Overview:

    With ongoing innovations in motor and inverter technologies seeking to advance global decarbonization objectives in the automotive industry, it’s crucial that engineers have a thorough understanding of how to properly analyze these systems.

    This complimentary webinar provides engineering professionals involved in motor and control system development with insights that enable data benchmarking and troubleshooting issues related to energy efficiency in electric vehicle (EV) powertrains.

    Key webinar topics include:

    • Establishing baselines for system efficiency
    • Conducting inverter control signal analysis at the systems level
    • Identifying critical measurements for benchmarking inverter input, inverter output, and motor output
    • Analyzing motor control signals, including torque control variables, positional sensors, and pulse-width modulation (PWM), as well as torque measurements