The SL2000 high-speed data acquisition unit is an isolated oscilloscope/High-speed DAQ for embedded systems.
The same plug-in modules as the DL950 and DL350 can be used.
With just one SL2000 unit, you can simultaneously record isolated analog signals from low voltage to 1000V, digital signals, encoder signals, CAN/CAN FD/LIN/SENT communication signals from in-vehicle networks, and NVH signals such as vibration, strain, and temperature.
The SL2000 is a 4U-high isolated oscilloscope/High-speed DAQ for system integration that allows the DL950 to be mounted in a system rack.
By combining plug-in modules, it is possible to perform long-term multi-channel recording of voltage, current, temperature, acceleration, strain, pulse, digital, and CAN/CAN FD/LIN/SENT communication signals.
Capture signals at speeds up to 200 MS/s, and scale to 160 channels by linking as many as five synchronized units.
Real-time waveform calculation, power calculation, and motor dq analysis are supported-including trigger conditions based on computed results.
A variety of plug-in modules are available to measure signals such as voltage, temperature, acceleration, strain, and CAN bus data.
IS8000 makes it easy to configure instruments and recording settings for standardized and long duration tests-without the need for complex programming.
There are two modes, "Scope Mode" and "Memory Recorder Mode", to suit the environment and purpose.
Scope Mode
Memory Recorder Mode
High-speed sampling of up to 200 MS/s 14 bits is possible, allowing you to accurately capture switching waveforms of high-speed inverters and rapid noise around power supplies.
In addition, when combined with a large-capacity memory of up to 8 G points, you can record continuously for up to 20 seconds even at high-speed sampling of 200 MS/s.
The Action on Trigger function automatically performs predefined tasks-such as saving data files, activating a buzzer, or sending email notifications-when a trigger condition is met. Additionally, it can perform pass/fail (GO/NO-GO) evaluations based on waveform parameters such as shape or amplitude, and execute actions based on the result.
With up to 8 G points of memory and 20 seconds of continuous capturing, even at 200 MS/s, no signal changes are missed.
*Up to 4 G points of memory is allocated per channel.
The 512 GB internal SSD can record for long periods of time at up to 2 MS/s. Waveforms from dual capture can also be recorded, which is useful for in-vehicle endurance testing and capturing rare spontaneous events.
Long time recording at up to 20 MS/s, which is 100 times faster than the previous model, is available. You can capture data anywhere you cannot bring a PC such as on-vehicle or field testing. The flash memory is non-volatile, so the captured data stays in the instrument even after turning off the power. Data can later be transfered to a PC.
Sample rates can be set by channel. Reducing the sample rate reduces the amount of data even when modules with high and low sample rates are mixed together. This allows for less memory space to be used and improves the transfer speed.
• Built-in SSD 512 GB
• SD Memory Card (SD/SDHC/SDXC)
• USB Storage up to 8 TB
• Network Drive
In Hybrid Electric Vehicle (HEV) development, two or four motor systems, with each motor connected to a driving wheel, are commonly used. This design eliminates traditional powertrains, simplifying the overall system and alleviating concerns when driving a 4WD on snowy roads. The multi-channel, high-speed, isolated DL950 can simultaneously capture and analyze signals from these multi-motor setups.
Renewable energy sources like hydro, solar, and wind power are integrated into the power grid, driving the transition to a sustainable society. The DL950/SL2000 supports this transition with its long-term power recording and analysis capabilities. For example, wind turbines require synchronized monitoring of power generation efficiency at multiple locations, which can be achieved with high precision using GPS or IRIG signals.
Additionally, the DC/AC conversion efficiency of solar panel-generated DC power can be accurately measured using the WT5000 precision power analyzer, while the waveform data from the DL950/SL2000 can be seamlessly integrated with the WT5000’s measurement data to provide a comprehensive analysis of inverter performance.
Vibration is inherent to "moving objects" such as motors and engines. Analyzing the frequency of vibrations to identify abnormal areas is an essential test in the development of "moving objects." By using multiple acceleration modules, Vibrations at multiple points can be simultaneously captured and up to eight vibration frequencies can be analyzed using FFT functionality to identify faulty components.
By using the DL950 and SL2000, we can simultaneously record the voltage, current, and rotational speed of the battery, inverter, and drive motor, as well as the vibration and interior temperature of railway vehicles.
You can simultaneously view the trends of physical values from CAN/CAN FD bus data alongside the corresponding measured waveforms on the same screen. For example, you can verify the correlation between the ON/OFF signal of the ignition switch, the corresponding CAN/CAN FD signal, and the actual signals from related pressure sensors, all on the same screen. By connecting a GPS unit, Latitude, longitude, altitude, speed, direction, and time information can be added to the measurement data. Using DIAdem, you can simultaneously display the measurement data and driving position. With IoT gateways or M2M routers, remote control and data monitoring can be performed wirelessly.
This software offers an API (Application Programming Interface) for waveform data acquisition with DL950/SL2000, the API is provided as a Dynamic Link Library (DLL). By integrating this DLL into your custom application, you can easily leverage the API for automated measurements via PC control. It supports four key operations:
Free Run Mode:
Continuously acquires data from the start to the stop of the waveform capture.
Trigger Mode:
Captures waveforms based on a specified trigger event.
Flash Acquisition Data Access Library Functionality: Transfers recorded flash acquisition waveforms from the DL950/SL2000 to a PC.
File Operation and Transfer Functionality:
Transfers recorded waveforms from the DL950/SL2000 to a PC.
The IS8000 enables synchronized measurements with DL950s, Yokogawa power meters, other manufacturers’ high-speed cameras, and other equipment. It supports measurement setting, remote monitoring, comparative analysis, and MDF file saving to reduce test system development time.
IS8002CDV is the successor to the data viewer software Xviewer, and enables remote operation of measuring instruments, data file transfer, waveform display, zooming, automatic measurement of waveform parameters, waveform calculation (optional), data format conversion, and more.
High-Speed 100 MS/s 12-Bit Isolation Module (2 channels)
IsoPRO technology enables 1kV isolated measurements in combination with 700929 or 701947 probe and is designed for inverter / IGBT related applications in mind. Using high speed optical fiber-based transmission, the module achieves high speed ADC clock and data isolation and provides the performance needed to develop high efficiency inverters, which employ high voltages, large currents, and ever increasing switching speeds.
Applicable to DL350, DL850 series, DL950 and SL1000.
High-speed 10 MS/s 16-Bit isolation module (4 channels) – High noise immunity. Suitable for testing and longterm monitoring for power generators and multi-output power supplies. Provides dynamic analysis of multi-channel data recording applications. For use with the DL950 ScopeCorder.
Max. sampling rate: 10 MS/s
A/D conversion resolution: 16 bit
Number of channels: 4
Max. input voltage (DC + ACpeak): 600V / 200V
High-Speed 10 MS/s 12-Bit non-isolation Module (2 ch)
Non-Isolation version of model 720250
Applicable to DL350, DL850 series, DL950 and SL1000.
Temperature/high-precision voltage Module (2 ch)
Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (1 mV), and low noise (±4 µVtyp)
Applicable to DL350, DL850 series, DL950 and SL1000.
Strain Module with Shunt Calibration, type DSUB (2 channels) to be used in combination with 701957 or 701958 DSUB bridge head.
Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.
Applicable to DL350, DL850 series, DL950 and SL1000.
Use the SENT monitoring module to decode the SENT protocol signal and display information on physical quantities from SENT output sensors.
Applicable to DL850V & DL850EV, DL350 (/VE option), DL950 (/VCE option) ScopeCorder Vehicle Edition only.
Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series
Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 0.5 Arms/5 Arms/30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments
The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.
The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.
Industry leading high precision, high current AC/DC split core measurement. Compatible with power analyzers and waveform measurement instruments.
1000 Vrms CAT III, 1 set each of red and black
Equivalent to B9852MM (Color Black)
Equivalent to B9852NM (Color Red)
Set contains one black and one red clip.
1000 Vrms-CAT II.
Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.
A subassembly of 1.2 m long test leads with alligator-clip adapters.
Use only for circuits having voltage levels no greater than 42 V.
Applicable for SL1000 & SL1400.
For conversion between BNC and female banana plug
Applicable for DL750/DL750P, SL1000 & SL1400.
8-bit, non-isolated, response speed: 3µs or less, treshold level approx 1.4V
702911: 1 meter cable, 702912: 3 meter cable
8-bit, non-isolated, response speed: 1µs, threshold level approx 1.4V
Two measurement leads (B9879PX and B9879KX) included.
2 pieces (red and black) in 1 set
length: 1.00 m
Used in combination with the 701959, 758921, 758922, or 758929
Rating: 1000 V CAT III/19 A
Connected to the 700929, 701947
Maximum input voltage: 1,000V (DC + ACpeak)
Length: 0.26m/0.3m/0.4m
Applicable for DL750/DL750P, SL1000, SL1400
Set contains one black and one red clip
1000 Vrms-CAT II
2 pieces (red and black) in 1 set
Connected to the 758933, 758917, or 701901
Length: 0.3m
Applicable for DL750/DL750P, SL1000, SL1400
For 702902, 702906
BNC-BNC 2m. For connection to simultaneously measurement with 2 units, or for input external trigger signal.
For DL950,SL2000 multi-unit connection
For DL950,SL2000 multi-unit connection, 3 m
Maximum power point tracking (MPPT) charge controllers play a crucial role in the optimization of renewable energy system efficiency and performance. Through dynamic tracking of a renewable energy source’s maximum power point, an MPPT controller enables more efficient energy harvesting, faster charging, and adaptability to changing environmental conditions.
ANIS8000APP02-01EN
ANIS8000APP04-01EN
DL950_Comprehensive_evaluation_of_vehicle_systems_using_real_signal
DL950_Evaluation_of_ECU_and_InverterMotor
【search key】DL9 ,DL95 ,DL
This video overview of the IS8000 Integrated Software Platform showcases how our integrated solution accelerates engineering workflow and provides a visual tour of this software that tightly integrates timing, control, and data collection from multiple test and measurement instruments.
Test and measurement engineering work groups can have differing priorities and requirements, which often results in multiple instrumentation systems and data file formats, as well as incompatible reporting. This lack of effective communication between groups and instruments causes decreased efficiency and quality and increased spending and time to market. Unify test and measurement instrumentation, software, and data across engineering teams with a suite of solutions that caters to the different needs of engineering work groups, including accurate power data, fast sampling rates, long recordings of multiple different input types, and insights into waveform data.
Looking for a turnkey high-speed data transfer solution with better bandwidth and minimal manual overhead?
The 10Gb Ethernet option on the Yokogawa Test&Measurement DL950 ScopeCorder fits that very role and makes capturing and recording high-speed data seamless and convenient.
Record data at 50 times the speeds of traditional Ethernet and USB connections and automatically transfer data to your PC in a single step using the IS8000 Integrated Software Platform.
CAN Bus communication is widely used in the transportation industry where reliable transmission of data is paramount. Monitoring and recording these communications can be easier when using the proper instruments. In this video, a Yokogawa Test&Measurement Applications Engineer demonstrates how to setup the DL950 ScopeCorder to read the temperature of a motor drive alongside its voltage and current output.
The multi-unit synchronization option for the Yokogawa Test&Measurement DL950 ScopeCorder lets you time synchronize up to five DL950 ScopeCorders, for up to 160 channels of voltage, current, temperature, strain measurements, and more. This video walks you through how to set up and connect the multiple DL950 ScopeCorders, take measurements, and pull the data from all of the instruments for analysis with the IS8000 Integrated Test and Measurement Software Platform.
Having multiple memory options allows engineering groups to optimize how data is stored, no matter if you need to record for a long time at slower sampling rates, do a fast capture at high sampling rates, or anything in between.
The Yokogawa Test&Measurement DL950 ScopeCorder operates as an oscilloscope and incorporates the ability to record data for long periods of time like a data acquisition recorder. There are four memory types on the DL950 ScopeCorder: internal memory, solid state drive, flash memory, and PC storage through the IS8000 Integrated Test and Measurement Software Platform. This videos talks about the advantages of each of these and how to pick the best data recording method for you.
With ongoing innovations in motor and inverter technologies seeking to advance global decarbonization objectives in the automotive industry, it’s crucial that engineers have a thorough understanding of how to properly analyze these systems.
This complimentary webinar provides engineering professionals involved in motor and control system development with insights that enable data benchmarking and troubleshooting issues related to energy efficiency in electric vehicle (EV) powertrains.
Key webinar topics include: