50 MHz, 1000:1 / 100:1, Max. Differential Voltage: 5000 Vrms and 7000 Vpeak or less
Probe Power : probe power supply
150 MHz, 500:1 / 50:1, Max. Differential Voltage:±1500 V (DC + ACpeak)
Probe Power:probe power supply
500 MHz, 50:1, Max. Differential Voltage:±25 V(DC+ACpeak)
Probe Power:Dedicated probe interface
50 MHz, 1000:1/100:1, Max. Differential Voltage: 5000 Vrms/7000 Vpeak (1000:1), Probe Power: Internal battery or probe power supply B9852MJ power cable is bundled Work with Oscilloscopes, ScopeCorders
150 MHz, 500:1/50:1, Max. Differential Voltage: ±1400 V (DC + ACpeak) at 500:1, Probe Power: dedicated probe interface For DLM2000, DLM3000, DLM4000, DLM5000, DL6000, DLM6000, DL9000 and SB5000 series
100 MHz, 1000:1/100:1, Max. Differential Voltage: ±1400 V (DC + ACpeak) at 1000:1, Probe Power: Internal battery or probe power supply Work with Oscilloscopes, ScopeCorders
15 MHz, 100:1/10:1, Max. Differential Voltage: ±500 V (DC + ACpeak) or 350 Vrms at 100:1 attenuation, Probe Power: Internal battery or probe power supply Work with Oscilloscopes, ScopeCorders
100 MHz, 100:1/10:1, Max. Differential Voltage: ±700 V (DC + ACpeak) at 100:1 attenuation, Probe Power: Internal battery or probe power supply
1 GHz, 50:1, Max. Differential Voltage: ±25 V (DC + ACpeak), Probe Power: dedicated probe interface
500 MHz, 10:1, Max. Differential Voltage: ±12 V (DC + ACpeak), Probe Power: probe power supply Work with 50 Ω input system oscilloscope
200 MHz, 10:1, Max. Differential Voltage: ±20 V (DC + ACpeak), Probe Power: probe power supply Work with 50 Ω input system oscilloscope
200 MHz, 10:1, ±1000 V (DC + ACpeak) CAT II, 2.5 m,Wide operating temperature range (−40 to +85°C)
For DLM2000, DLM4000 series.
500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m Supplied standard with DLM3000, DLM5000 series
200 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.5 m
For DLM2000 (200 MHz model)
500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m
For DLM2000, DLM4000, DL6000, DLM6000 series
10 MHz, 10:1/1:1, 600 V (DC + ACpeak) CAT II, 1.5 m
For ScopeCorder Non-Isolated Modules
500 MHz, 10:1, 400 Vrms/1250 Vpeak CAT I 300 Vrms CAT II, 1.2 m
For DLM2000, DLM4000, DL6000, DLM6000 series
400 MHz, 100:1, 1000 Vrms CAT II 4000 V transient over-voltage CAT I, 1.2 m
For DL1700, DLM2000, DLM3000, DLM4000, DLM5000, DL/6000, DLM6000, DL9000 and SB5000 series
250 MHz, 100:1, 1000 Vrms CAT II 4000 V transient over-voltage CAT I, 3 m
For DL1700, DLM2000, DLM3000, DLM4000, DLM5000, DL/6000, DLM6000, DL9000 and SB5000 series
100 MHz, 10:1, Isolated BNC, 1000 V CAT II, 1.5 m
For ScopeCorder Isolated Modules
Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series
200 MHz, 100:1, Isolated BNC, ±1000 V (DC + ACpeak) CAT II ±3540 V (DC + AC peak) CAT I, 1.5 m
For ScopeCorder Isolated Modules
900 MHz, 10:1, ±10 V (DC + ACpeak), 1.5 m, Probe Power: probe power supply
500 MHz, 10:1, 400 Vrms, 1250 V transient over-voltage CAT I, 300 Vrms CAT II, 1.2 m
For DL1700E, DL7400 series
350 MHz, 10:1, 400 Vrms, 1250 V transient over-voltage CAT I, 300 Vrms CAT II, 3 m
For DL1700E, DL7400 series
200 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m For DL1600 series
400 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m For DL1700, DL1700E, DL7200, DL7400 series
400 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m
For DL9000, DL9700/DL9500, SB5000 series
Frequency bandwidth: DC to 50 MHz
Maximum continuous input range: 5 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments.
Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 5 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments.
Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.
Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.
Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.
Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.
Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.
Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.
The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.
The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.
Special AC-Input Clamp-on Probes for Large-current Hot Line Measurement
8-bit, non-isolated, response speed: 3µs or less, treshold level approx 1.4V
702911: 1 meter cable, 702912: 3 meter cable
8-bit, non-isolated, response speed: 1µs, threshold level approx 1.4V
Two measurement leads (B9879PX and B9879KX) included.
8-bit, isolated, response speed: 1ms or less (DC), 20ms or less (AC), treshold level 6VDC or 50VAC.
To be used with measurement lead 758917 and 758922, 758929 or 701954 adapter leads.
90020B -50 to 600°C (rounded end)
90021B -50 to 600°C (rounded end)
90022B -50 to 600°C (rounded end)
90023B -50 to 500°C (needle)
90024B -50 to 500°C (needle)
90029B -40 to 260°C (Bead TC)
90030B -20 to 250°C (Surface straight)
90031B -20 to 250°C (Surface angled)
90032B -20 to 500°C (Surface straight)
90033B -20 to 500°C (Surface angled)
90050B -50 to 600 ° C (For liquids)
90051B -50 to 600 ° C (For liquids)
90055B -20 to 250 ° C (For surfaces)
90056B -20 to 500 ° C (For surfaces)
Using a probe stand with a flexible arm and heavy base to hold and stabilize probes can simplify circuit board testing.
A power supply for current probes, FET probes, and differential probes. Supplies power for up to four probes, including large current probes.
200 MHz, 10:1, ±1000V (DC + ACpeak) CAT II, 2.5 m
Operating environment: −40 to +85°C (no condensation)
For DLM3000, DLM5000 series.
500 MHz, 10:1, 400 Vrms, 1.3 m
For DLM3000, DLM5000 series
Frequency bandwidth: DC to 50 MHz
Maximum continuous input range: 0.5 Arms/ 5 Arms/ 30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments
Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 0.5 Arms/5 Arms/30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments