Probes

50 MHz, 1000:1/100:1, Max. Differential Voltage: 5000 Vrms/7000 Vpeak (1000:1), Probe Power: Internal battery or probe power supply B9852MJ power cable is bundled Work with Oscilloscopes, ScopeCorders

150 MHz, 500:1/50:1, Max. Differential Voltage: ±1400 V (DC + ACpeak) at 500:1, Probe Power: dedicated probe interface For DLM2000, DLM3000, DLM4000, DLM5000, DL6000, DLM6000, DL9000 and SB5000 series

100 MHz, 1000:1/100:1, Max. Differential Voltage: ±1400 V (DC + ACpeak) at 1000:1, Probe Power: Internal battery or probe power supply Work with Oscilloscopes, ScopeCorders

15 MHz, 100:1/10:1, Max. Differential Voltage: ±500 V (DC + ACpeak) or 350 Vrms at 100:1 attenuation, Probe Power: Internal battery or probe power supply Work with Oscilloscopes, ScopeCorders

100 MHz, 100:1/10:1, Max. Differential Voltage: ±700 V (DC + ACpeak) at 100:1 attenuation, Probe Power: Internal battery or probe power supply

1 GHz, 50:1, Max. Differential Voltage: ±25 V (DC + ACpeak), Probe Power: dedicated probe interface

500 MHz, 10:1, Max. Differential Voltage: ±12 V (DC + ACpeak), Probe Power: probe power supply Work with 50 Ω input system oscilloscope

200 MHz, 10:1, Max. Differential Voltage: ±20 V (DC + ACpeak), Probe Power: probe power supply Work with 50 Ω input system oscilloscope

200 MHz, 10:1, ±1000 V (DC + ACpeak) CAT II, 2.5 m,Wide operating temperature range (−40 to +85°C)
For DLM2000, DLM4000 series.

500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m Supplied standard with DLM3000, DLM5000 series

200 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.5 m
For DLM2000 (200 MHz model)

500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m
For DLM2000, DLM4000, DL6000, DLM6000 series

10 MHz, 10:1/1:1, 600 V (DC + ACpeak) CAT II, 1.5 m
For ScopeCorder Non-Isolated Modules

500 MHz, 10:1, 400 Vrms/1250 Vpeak CAT I 300 Vrms CAT II, 1.2 m
For DLM2000, DLM4000, DL6000, DLM6000 series

400 MHz, 100:1, 1000 Vrms CAT II 4000 V transient over-voltage CAT I, 1.2 m
For DL1700, DLM2000, DLM3000, DLM4000, DLM5000, DL/6000, DLM6000, DL9000 and SB5000 series

250 MHz, 100:1, 1000 Vrms CAT II 4000 V transient over-voltage CAT I, 3 m
For DL1700, DLM2000, DLM3000, DLM4000, DLM5000, DL/6000, DLM6000, DL9000 and SB5000 series

100 MHz, 10:1, Isolated BNC, 1000 V CAT II, 1.5 m
For ScopeCorder Isolated Modules

Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series

200 MHz, 100:1, Isolated BNC, ±1000 V (DC + ACpeak) CAT II ±3540 V (DC + AC peak) CAT I, 1.5 m
For ScopeCorder Isolated Modules

60 MHz, 10:1, Isolated BNC, ±1000 V (DC + ACpeak) CAT II, 2.5 m
Wide operating temperature range(-40 to +85°C)
For ScopeCorder Isolated Modules

900 MHz, 10:1, ±10 V (DC + ACpeak), 1.5 m, Probe Power: probe power supply

500 MHz, 10:1, 400 Vrms, 1250 V transient over-voltage CAT I, 300 Vrms CAT II, 1.2 m
For DL1700E, DL7400 series

350 MHz, 10:1, 400 Vrms, 1250 V transient over-voltage CAT I, 300 Vrms CAT II, 3 m
For DL1700E, DL7400 series

200 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m For DL1600 series

400 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m For DL1700, DL1700E, DL7200, DL7400 series

400 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m
For DL9000, DL9700/DL9500, SB5000 series

1 set 4 pcs Red Black White Blue Ø 4 mm Approx. 3 m

Frequency bandwidth: DC to 50 MHz

Maximum continuous input range: 5 Arms

Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments.  

Frequency bandwidth: DC to 120 MHz

Maximum continuous input range: 5 Arms

Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments.

Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.

Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.

Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 50 A
  • 40 Hz to 3.5 kHz Bandwidth

The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 200 A
  • 40 Hz to 3.5 kHz Bandwidth

Special AC-Input Clamp-on Probes for Large-current Hot Line Measurement

AC 200 A: output AC 2.5 mV/A

AC 500 A: output AC 1.0 mV/A

AC 50 A: output AC 10 mV/A

AC 2 A: output AC 25 mV/A

φ40 mm AC 2 A, Leakage current measurement.

φ18 mm AC 50 A, Load current measurement.

φ24 mm AC 100 A, Load current measurement.

φ30 mm AC 200 A, Load current measurement.

φ40 mm AC 500 A, Load current measurement.

max. approx. 110 mm
AC 1000 A flexible type load current measurement

max. approx. 150 mm
AC 3000 A, 3 CH Load current measurement.

AC/DC clamp probe
AC: 130 A (40 Hz to 1 kHz)
DC: ±180 A

701988 (PBL100) Logic Probe

100 kΩ input resistance, toggle frequency of 250 MHz

8-bit, non-isolated, response speed: 3µs or less, treshold level approx 1.4V
702911: 1 meter cable, 702912: 3 meter cable

8-bit, non-isolated, response speed: 1µs, threshold level approx 1.4V
Two measurement leads (B9879PX and B9879KX) included.

8-bit, isolated, response speed: 1ms or less (DC), 20ms or less (AC), treshold level 6VDC or 50VAC.
To be used with measurement lead 758917 and 758922, 758929 or 701954 adapter leads.

90029B -40 to 260°C (Bead TC)

90020B -50 to 600°C (rounded end)
90021B -50 to 600°C (rounded end)
90022B -50 to 600°C (rounded end)
90023B -50 to 500°C (needle)
90024B -50 to 500°C (needle)
90029B -40 to 260°C (Bead TC)

90030B  -20 to 250°C  (Surface straight)
90031B  -20 to 250°C  (Surface angled)
90032B  -20 to 500°C  (Surface straight)
90033B  -20 to 500°C  (Surface angled)

90050B -50 to 600 ° C (For liquids)
90051B -50 to 600 ° C (For liquids)
90055B -20 to 250 ° C (For surfaces)
90056B -20 to 500 ° C (For surfaces)

Length: 1.4 m, MY600 only

Length: 2.0 m, Earth probe and alligator clip adapters

Size: 61.9 × 26 mm

Logic probe accessory kit for use with 701989.

Using a probe stand with a flexible arm and heavy base to hold and stabilize probes can simplify circuit board testing.

A power supply for current probes, FET probes, and differential probes. Supplies power for up to four probes, including large current probes.

500 MHz, 10:1, 400 Vrms, 1.3 m
For DLM3000, DLM5000 series

200 MHz, 10:1, ±1000V (DC + ACpeak) CAT II, 2.5 m
Operating environment: −40 to +85°C (no condensation)
For DLM3000, DLM5000 series.

Looking for more information on our people, technology and solutions?


Contact Us
Top