A probe is a device that takes and relays measurements.
500 MHz, 50:1, Max. Differential Voltage:±25 V(DC+ACpeak)
Probe Power:Dedicated probe interface
200 MHz, 10:1, ±1000 V (DC + ACpeak) CAT II, 2.5 m. Wide operating temperature range (−40 to +85°C).
For DLM2000, DLM4000 series oscilloscopes.
500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m Supplied standard with DLM3000, DLM5000 series
200 MHz, 10:1, Max. Differential Voltage: ±20 V (DC + ACpeak), Probe Power: probe power supply. Works with 50 Ω input system oscilloscope.
500 MHz, 10:1, 400 Vrms/1250 Vpeak CAT I 300 Vrms CAT II, 1.2 m
For DLM2000, DLM4000, DL6000, DLM6000 series
Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series
400 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m
For DL9000, DL9700/DL9500, SB5000 series
701928 current probe
Front-end powered
Recognized automatically
Adjust zero position from operation of DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000, SB5000
The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.
The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.
Special AC-Input Clamp-on Probes for Large-current Hot Line Measurement
8-bit, non-isolated, response speed: 3µs or less, treshold level approx 1.4V
702911: 1 meter cable, 702912: 3 meter cable
8-bit, non-isolated, response speed: 1µs, threshold level approx 1.4V
Two measurement leads (B9879PX and B9879KX) included.
90020B -50 to 600°C (rounded end)
90021B -50 to 600°C (rounded end)
90022B -50 to 600°C (rounded end)
90023B -50 to 500°C (needle)
90024B -50 to 500°C (needle)
90029B -40 to 260°C (Bead TC)
90030B -20 to 250°C (Surface straight)
90031B -20 to 250°C (Surface angled)
90032B -20 to 500°C (Surface straight)
90033B -20 to 500°C (Surface angled)
90050B -50 to 600 ° C (For liquids)
90051B -50 to 600 ° C (For liquids)
90055B -20 to 250 ° C (For surfaces)
90056B -20 to 500 ° C (For surfaces)
200 MHz, 10:1, ±1000V (DC + ACpeak) CAT II, 2.5 m
Operating environment: −40 to +85°C (no condensation)
For DLM3000, DLM5000, DLM5000HD series.
500 MHz, 10:1, 400 Vrms, 1.3 m
For DLM3000, DLM5000, DLM5000HD series
Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 0.5 Arms/5 Arms/30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments
Measure high currents without disassembling existing cabling. Compatible with power analyzers and waveform measurement instruments.
To best utilize SiC devices for improved energy efficiency in equipment, it is important to optimize the internal device peripheral circuits in the inverter according to the device characteristics.
In research published by Yale University's Journal of Industrial Ecology (now owned and managed by the International Society of Industrial Ecology), researchers from the University of Nottingham and Dartmouth University use a Yokogawa Test&Measurement CW240 Clamp-On Power Analyzer to measure the real power consumption of the investigated printing systems.