A probe is a device that takes and relays measurements.
50 MHz, 1000:1 / 100:1, Max. Differential Voltage: 5000 Vrms and 7000 Vpeak or less
Probe Power : probe power supply
150 MHz, 500:1 / 50:1, Max. Differential Voltage:±1500 V (DC + ACpeak)
Probe Power:probe power supply
500 MHz, 50:1, Max. Differential Voltage:±25 V(DC+ACpeak)
Probe Power:Dedicated probe interface
1 GHz, 50:1, Max. Differential Voltage: ±25 V (DC + ACpeak), Probe Power: dedicated probe interface
200 MHz, 10:1, ±1000 V (DC + ACpeak) CAT II, 2.5 m,Wide operating temperature range (−40 to +85°C)
For DLM2000, DLM4000 series.
500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m Supplied standard with DLM3000, DLM5000 series
200 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.5 m
For DLM2000 (200 MHz model)
500 MHz, 10:1, 400 Vrms/1250 Vpeak CAT I 300 Vrms CAT II, 1.2 m
For DLM2000, DLM4000, DL6000, DLM6000 series
400 MHz, 100:1, 1000 Vrms CAT II 4000 V transient over-voltage CAT I, 1.2 m
For DL1700, DLM2000, DLM3000, DLM4000, DLM5000, DL/6000, DLM6000, DL9000 and SB5000 series
Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series
400 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m
For DL9000, DL9700/DL9500, SB5000 series
Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.
Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.
The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.
The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.
Special AC-Input Clamp-on Probes for Large-current Hot Line Measurement
8-bit, non-isolated, response speed: 3µs or less, treshold level approx 1.4V
702911: 1 meter cable, 702912: 3 meter cable
8-bit, non-isolated, response speed: 1µs, threshold level approx 1.4V
Two measurement leads (B9879PX and B9879KX) included.
8-bit, isolated, response speed: 1ms or less (DC), 20ms or less (AC), treshold level 6VDC or 50VAC.
To be used with measurement lead 758917 and 758922, 758929 or 701954 adapter leads.
90020B -50 to 600°C (rounded end)
90021B -50 to 600°C (rounded end)
90022B -50 to 600°C (rounded end)
90023B -50 to 500°C (needle)
90024B -50 to 500°C (needle)
90029B -40 to 260°C (Bead TC)
90030B -20 to 250°C (Surface straight)
90031B -20 to 250°C (Surface angled)
90032B -20 to 500°C (Surface straight)
90033B -20 to 500°C (Surface angled)
90050B -50 to 600 ° C (For liquids)
90051B -50 to 600 ° C (For liquids)
90055B -20 to 250 ° C (For surfaces)
90056B -20 to 500 ° C (For surfaces)
200 MHz, 10:1, ±1000V (DC + ACpeak) CAT II, 2.5 m
Operating environment: −40 to +85°C (no condensation)
For DLM3000, DLM5000 series.
500 MHz, 10:1, 400 Vrms, 1.3 m
For DLM3000, DLM5000 series
Frequency bandwidth: DC to 50 MHz
Maximum continuous input range: 0.5 Arms/ 5 Arms/ 30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments
Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 0.5 Arms/5 Arms/30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments