Current Probes

Current probes allow you to measure DC or AC current. Yokogawa's selection of current probes allow measurements ranges up to 500 ARMS and bandwidths up to 100MHz.

  • Frequency bandwidth: DC to 50 MHz

    Maximum continuous input range: 5 Arms

    Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments.  

  • Frequency bandwidth: DC to 120 MHz

    Maximum continuous input range: 5 Arms

    Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments.

  • Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.

  • Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.

  • Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

  • Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

  • Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

  • Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

  • The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

    • AC 50 A
    • 40 Hz to 3.5 kHz Bandwidth
  • The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

    • AC 200 A
    • 40 Hz to 3.5 kHz Bandwidth

Relationship between the Current being Measured and Probe's Current Consumption
(Typical Values)

When using the DL/DLM/SL main unit to power the current probes, make sure that the total current consumption of the probes does not exceed the unit's probe power rating. For the probe power rating of each model, please check by the following information.

Relation between the power supply and the maximum measured current

Current probe 701933 701929

Current probe 701932 701928

Current probe 701930

Current probe 701931

The Maximum input current value is derated with frequency;
as the frequency increases, the maximum input current rating decreases.

701917
 
701918
 
701929, 701933
 
701928, 701932
 
701930
 
701931