Current Probes

Current probes allow you to measure DC or AC current. Yokogawa's selection of current probes allow measurements ranges up to 500 ARMS and bandwidths up to 100MHz.

  • 701917 oscilloscope current probe
  • Frequency bandwidth: DC to 50 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments
  • Yokogawa 701918 Current Probe
  • Frequency bandwidth: DC to 120 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.

  • 701929 Current Probe 50 MHz / 30 ARMS
  • Front-end powered
  • Auto-recognized
  • DLM2000-4000, DL/DLM6000, DL/DLM9000, SB5000
  • 701930 Current Probe 10 MHz / 150 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

  • 701932 Current Probe 100 MHz / 30 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders, or external power supply
  • 701933 50 by 30 current probe
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

Frequency bandwidth: DC to 50 MHz
Maximum continuous input range: 0.5 Arms/ 5 Arms/ 30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments

Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 0.5 Arms/5 Arms/30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments

The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 50 A
  • 40 Hz to 3.5 kHz Bandwidth

The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 200 A
  • 40 Hz to 3.5 kHz Bandwidth

Relationship between the Current being Measured and Probe's Current Consumption
(Typical Values)

When using the DL/DLM/SL main unit to power the current probes, make sure that the total current consumption of the probes does not exceed the unit's probe power rating. For the probe power rating of each model, please check by the following information.

Relation between the power supply and the maximum measured current

Current_Probe

702915,702916 Current_Probe

The Maximum input current value is derated with frequency;
as the frequency increases, the maximum input current rating decreases.

701917

701917

 
701918

701918

 
701929, 701933

701929, 701933

 
701928, 701932

701928, 701932

 
701930

701930

 
701931

701931

 
702915

702915

 
702916

702916

Looking for more information on our people, technology and solutions?


Contact Us
Top