Renewable energy systems such as solar photovoltaic (PV) panels and wind turbines often generate variable power outputs due to fluctuating environmental conditions. To efficiently harness the available energy from these sources, maximum power point tracking (MPPT) charge controllers are used. The primary function of MPPT is regulation of electrical energy flow from solar panels or wind turbines to batteries through continuous adjustment of voltage and current, which ensures maximum power is extracted.
Charge controllers are part of power conditioning systems (PCS), a set of devices and equipment that ensures electricity generated from renewable sources meets specific quality, stability, and compatibility requirements for use in electrical systems. PCS plays a crucial role in integrating renewable energy sources into both existing power grids and standalone systems to improve reliability, efficiency, and safety. This application note provides an overview of MPPT charge controllers along with their benefits, principles of operation, and how to measure their efficiency.
Figure 1. Measurement of Power Conversion Efficiency in a Photovoltaic Power Generation System
MPPT charge controllers dynamically adjust the operating point of a source to its maximum power point (MPP) and varies with changing environmental conditions such as solar irradiance or wind speed. Each solar panel and wind generator has an I-V (current-voltage) curve that represents the relationship between current output and voltage across the terminals of a panel under varying conditions. The MPP on the I-V curve is the point at which the product of voltage and current is highest. The charge controller finds MPP through incremental adjustments to operating voltage or current and measures the corresponding changes in power output at each point. It then uses an algorithm (typically perturb and observe aka P&O, incremental conductance, or fuzzy logic) to compare power output at the current operating point with the previous operating point. Once it determines if power output is higher or lower, operating parameters are adjusted accordingly. The charge controller repeats this process until MPP is found. This dynamic tracking allows the system to adapt to changing conditions and maintain high efficiency across a range of operating conditions.
Figure 2. MPPT Control voltage, current, and power measurements
An MPPT controller typically employs a DC-DC converter that switches between different states (i.e., both conversion and regulation of voltage and current) to convert higher voltage into lower voltage required for battery charging.
The MPPT algorithm directs a controller to adjust the duty cycle of a switch. If input voltage is higher than battery voltage, it is reduced using a buck converter. A switch turns on and off rapidly and creates pulses that are filtered by an inductor and capacitor to produce a stable lower voltage. If source voltage is lower than battery voltage, it is increased using a boost converter. Periodically, a switch connects and disconnects an inductor to the input and stores energy before releasing it at a higher voltage.
There are several advantages that make MPPT charge controllers the preferred choice for optimization of solar and wind power system performance and efficiency, especially in applications where energy harvest maximization and system reliability are critical.
Given losses in conversion and regulation, accurate measurement of a charge controller’s overall efficiency in converting solar and wind energy into usable electrical energy is important and requires an MPPT charge controller, source (solar panel, wind turbine, or variable DC source), compatible battery, an accuracy-focused power analyzer, and current sensors that can step down high currents that exceed the power analyzer’s range.
The example in this app note uses a Yokogawa Test&Measurement WT5000 Precision Power Analyzer to measure input power from the source and output power to the battery through voltage and current and then calculates efficiency using the equation (Pout/Pin) x 100%.
Figure 3. Voltage, current, power, and efficiency data
Using the data from Figure 3, source input is Urms1/Irms1/P1, charge controller output to the battery is Urms2/Irms2/P2, and charge controller efficiency is η1. Power and efficiency data is trended over time along with voltage, current, and power peak values, all of which are important to monitor as conditions change.
Figure 4. Input power, output power, and efficiency trend
Figure 5. Voltage, current, and power peak trend
MPPT charge controllers play a crucial role in the optimization of renewable energy system efficiency and performance. Through dynamic tracking of a renewable energy source’s maximum power point, an MPPT controller enables more efficient energy harvesting, faster charging, and adaptability to changing environmental conditions. Though charge controllers typically have a primary focus on battery management and load regulation, they are also important for broader power conditioning systems for renewable energy applications. When partnered with other components such as inverters, transformers, and protection devices, charge controllers ensure reliable and efficient operation of renewable energy systems to further the goal of clean and sustainable power.
This software (DL950FACQAPI.dll) provides an application programming interface (API) for transmitting waveform data stored in the flash acquisition area of a DL950 to a PC.
O oscilógrafo DL950 da Yokogawa captura e analisa uma ampla variedade de sinais elétricos, de sensores físicos a barramentos seriais. Ele oferece uma combinação única de altas taxas de amostragem, proporcionando uma visão detalhada, e longos tempos de registro para monitorar tendências ao longo do tempo.
A Yokogawa, a maior fabricante mundial de analisadores e medidores de energia e energia, fornece uma ampla gama de analisadores de energia digital para atender a todos os requisitos.
Accessories for digital power analyzers include various voltage and current transformers, clamp-on current probes, and a selection of test leads.