Auto & Manual Mode, Set Wavelength Range, Resolution, and Sensitivity | OSA Tutorial 2

Learn how to perform optical spectrum measurements using an Optical Spectrum Analyzer, from quick measurements with AUTO mode to advanced settings in MANUAL mode.

In this video, you'll learn:
・How to perform measurements using AUTO mode
・How to configure wavelength range settings
・How to set resolution and sensitivity
・Basic OSA measurement procedures

Explore Yokogawa Optical Spectrum Analyzer Solutions

Videos in the Series:

Produtos e Soluções Relacionadas

AQ6361 Telecom Production 1200 - 1700 nm

  • 0.03 nm resolution
  • ±20 pm accuracy
  • 65 dB close-in dynamic range
  • -80 dBm level sensitivity
  • Highest sweep speed
  •  

AQ6370 Optical Spectrum Analyzer

  • Yokogawa AQ6370 Optical Spectrum Analyzer
  • Re-defining Optical Spectrum Measurement Excellence

AQ6370E Telecom 600 - 1700 nm

  • 0.02 nm resolution
  • ±8 pm accuracy
  • 78 dB close-in dynamic range
  • -90 dBm level sensitivity
  • Single-mode and multi-mode

AQ6373E Visible Wavelength 350 - 1200 nm

  • 0.02 nm resolution
  • ±50 pm accuracy
  • 60 dB close-in dynamic range
  • -80 dBm level sensitivity
  • Single-mode and multi-mode
  • Industrial & biomedical laser testing

AQ6374E Wide Wavelength Range 350 - 1750 nm

  • 0.05 nm resolution
  • ±50 pm accuracy
  • 60 dB close-in dynamic range
  • -80 dBm level sensitivity
  • Single-mode and multi-mode
  • Visible to communications wavelengths

AQ6375E Long Wavelength 1000 - 2500 nm

  • 0.05 nm resolution
  • ±50 pm accuracy
  • 55 dB close-in dynamic range
  • 90 dB measurement dynamic range
  • -70 dBm level sensitivity
  • Single-mode and multi-mode
  • Advanced pulsed light measurement (APLM) mode

AQ6376E Three Micron 1500 - 3400 nm

  • 0.1 nm resolution
  • ±0.5 nm accuracy
  • 55 dB close-in dynamic range
  • 78 dB measurement dynamic range
  • -65 dBm level sensitivity
  • Single-mode and multi-mode
  • Advanced pulsed light measurement (APLM) mode
  •  

AQ6377E Five Micron 1900 - 5500 nm

  • 0.1 nm resolution
  • ±0.5 nm accuracy
  • 50 dB close-in dynamic range
  • 73 dB measurement dynamic range
  • -60 dBm level sensitivity
  • Single-mode and multi-mode
  • Advanced pulsed light measurement (APLM) mode
  •  

AQ6380 Highest Performance 1200 - 1650 nm

  • 0.005 nm (5 pm / 0.624 GHz) resolution
  • ±5 pm accuracy
  • 65 dB close-in dynamic range
  • -85 dBm level sensitivity
  • O, C, and L-bands

Optical Spectrum Analyzers

  • High-resolution measurement of optical power vs wavelength
  • Ideal for R&D, manufacturing, and laser characterization
  •  

Precision Making

Topo