AQ6319 Optical Spectrum Analyzer (DESCONTINUADO)

Aviso: Este produto foi descontinuado em Veja este produto de substituição:

The AQ6319 packs the power of cutting-edge technologies with many years of research and experience. It holds the best gratings based monochromator optical performance on the market and provides customers with a user-friendly interface for faster and more accurate measurement. In fact, the AQ6319 raises the standards in the optical testing industry.

With an unprecedented wavelength accuracy of ±10 pm (1520-1580 nm), the AQ6319 OSA has become an outstanding instrument in both general and specialized R&D labs for high accuracy wavelength measurement. Yokogawa keeps the "free-space" design between the incident beam and the monochrometer; this proven technology which is inherited from the world-renowned AQ6317 series OSAs offers much greater facility for researchers using specialty fibers, especially with large core diameters. The new AQ6319 offers a much faster sweep speed than any other models. It also features a LAN connection for faster and easier data transfer, as well as remote control capabilities. In addition, many new analysis functions have been included.
 

  • Ultra high Wavelength Accuracy
    ±10 pm (1520 to 1580 nm)
    ±20 pm (1450 to 1520 nm)
    ±20 pm (1580 to 1620 nm)
    ±50 nm (600 to 1700 nm)
    The above specs are after calibration with a built-in source
  • High Wavelength Linearity
    ±10 pm (1520 to 1580 nm)
    ±20 pm (1450 to 1520 nm)
    ±20 pm (1580 to 1620 nm)
    The above specs are after calibration with a built-in source
  • High Wavelength Resolution
    Provides maximum wavelength resolution at 10 pm
  • High Wavelength Resolution Accuracy
    Provides excellent wavelength resolution accuracy within ±2%
  • Best Optical Performance
    Wide close-in dynamic range:
    70 dB @ ±0.2 nm
    Fast sweep and quick response
  • Versatile Analysis Functions
    Comes with zooming and overview windows
  • Low Polarization Dependency
    Measurements such as gain of the optical amplifier can proceed accurately because polarization dependency is suppressed as low as ±0.05 dB.
  • High Power Measurement
    Max input power: +23 dBm per channel; Max safe input power: +27 dBm
  • Multiple Communication Interface
    GP-IB, LAN, printer, and others
  • Easy Operation with Mouse and Keyboard
  • Large Data Storage and Fast Data Transfer (FTP)

 

Notas de aplicação
Visão Geral:

Key Function

Visão Geral:

High Speed Stray Light Reduction Function

Visão Geral:

No, unfortunately due to the number of current fiber combinations, we do not stock optical fibers. There are many companies that specialize in optical fiber cords.

Visão Geral:

If you have products currently in China that require calibration or repair, you may either return them to your local Yokogawa service center or the Yokogawa China Service & Repair Center.   Please be advised that ...

Visão Geral:

Level Accuracy:Level Accuracy is a tolerance to the true value of measured value, when a standard level is measured with a standard wavelength. Level Linearity:Level Linearity is the width of error dispersion ...

Visão Geral:

Wavelength accuracy: Wavelength accuracy is a tolerance to the true value of a measured value when the standard wavelength is measured.  Wavelength repeatability:Wavelength repeatability is the stability of ...

Visão Geral:

The Chopped Light mode is used: To increase measurement level sensitivity by cutting the high frequency noise To detect only the light that the LS emitted, effective for free space measurement. In free space ...

Visão Geral:

Please download the attached application note for instructions on how to make High Bit Rate Modulated OSNR Measurement for the AQ6319 and AQ6370 series Optical Spectrum Analyzer..

Visão Geral:

If you are performing wavelength calibration using the instrument's built-in light source, the warning message is an indication that the monochromator needs to be repaired. Please visit our Contact site to locate ...

Visão Geral:
  • AQ6319 Optical Spectrum Analyzer
  • Warning "142 WL calibration failed"
  • Displayed when light source level is not enough at wavelength calibration or calibration cannot be executed because wavelength difference is out of calibration 