701917 Current Probe 50 MHz / 5 ARMS

What is the 701917 Current Probe?

701917 is a low noise compact current probe for measuring low-level currents from 1 mA to 5 A. Best suited for design and verification applications requiring high-sensitivity at low currents.

Frequency bandwidth: DC to 50 MHz

Maximum continuous input range: 5 Arms

Functions with Digital Oscilloscopes, ScopeCorders, and other waveform measuring instruments

How does a Current Probe Work?

Conductors' current flows cause electromagnetic flux fields. Oscilloscope current probes detect the fields' strength and convert it to voltage for an oscilloscope to measure for waveform analysis.

How to use a 701917 Current Probe

Before measuring, check that there are no problems with the instrument or the measurement target and that measurement preparations have been taken.

1. Pull the sensor opening lever to open the sensor head.

2. Align the direction of the arrow of the current direction mark indicated at the sensor tip to the direction of the measured current, and clamp so that the conductor is at the center of the sensor aperture. Low potential side (ground potential side) High potential side

3. Hold down the sensor opening lever until the JAW UNLOCKED indication disappears to lock the sensor head. The JAW UNLOCKED LED turns off.

4. You can observe the current waveform on the waveform measuring instrument. The output voltage rate of the 701917 and 701918 is 1 V/A. Convert the voltage sensitivity of the waveform measuring instrument to current sensitivity. For example, if the voltage sensitivity of the waveform measuring instrument is 10 mV/DIV, the current sensitivity is 10 mA/DIV.

  • Bandwidth: DC to 50 MHz; current measurement:  Max 5 Arms
  • 10x more sensitive than previous models 701928/701929/701932/701933
  • Low noise compact current probe for measuring low level currents from 1 mA to 5 A. 
  • Slim and light weight sensor head makes it easy to use in narrow spaces. 
  • Zero-adjustment can be done by simply pushing the button on the termination box. 
  • Demagnetization can also be done by holding down the DEMAG button for a quicker setup. 
  • Powered by the DL’s probe power supply terminal. 
  • The probes are also compatible with the 701934 probe power supply. 
  • Current values can be read directly on DL series instruments. Using the current probe selection menu eliminates the need to enter current/voltage conversion values.
  • LED driver, controller, power supply verification
  • Evaluation of the embedded power supply
  • Measurement of the power consumption of a low voltage device (FPGA)
  • Evaluation of the embedded component for household appliances and car electronics
  • Inverter currents
  • Switch mode power supply inrush currents

 

 

 