DL850/DL850V ScopeCorder (DISCONTINUED)

Notice: This product was discontinued on Dec 31, 2013. See this replacement product:

The DL850 ScopeCorder Series are modular, waveform recording instruments that can measure voltage, current, strain, acceleration, and other phenomena-- simultaneously.  With high speed sampling, high isolation withstand voltage, and multichannel measurements, the DL850 Series offers powerful support in the evaluation of electromechanical waveforms.

Introducing Our Ultra-Fast Memory Recorder

  • High-speed (up to 100 MS/s), High Resolution (up to 16-bit), Isolated (up to 1kV*1)
  • Multi-channel, up to 128 Voltage/Temperature or 128 logic bits
  • Continuous hard disk recording at 100 kS/s simultaneously on 16 channels*2
  • CAN and LIN buses monitoring and trend waveform display (DL850V only)
  • 17 plug-in modules

*1. With the isolated probe (700929 or 701947)
*2. With the /HD0 or /HD1 option

The DL850 ScopeCorder Series are modular, waveform recording instruments that can measure voltage, current, strain, acceleration, and other phenomena-- simultaneously. With high speed sampling, high isolation withstand voltage, and multichannel measurements, the DL850 Series offers powerful support in the development, evaluation, and quality control of energy efficient devices.

 

For increasingly fast inverter signals

High speed (100 MS/s), High resolution (12-bit), 1kV isolated measurements.*

Yokogawa's isoPRO technology offers industry-leading isolation performance at the highest speeds. The isoPRO core technology is designed with energy savings applications in mind. It gives you the performance needed to develop high efficiency inverters, which employ high voltages, large currents, and high operating speeds.

Example - Measuring Inverter Output
Dl850 EX1 1Accurately observe inverter startup waveforms with sufficient time resolution. You can confirm that no excessive overshoots occured.

 

 

 

 

 

 

IsoPRO Basic R 02 High Speed & High Withstand Voltage Isolation Technology  
DL850 EX2 Using high speed optical fiber-based transmissions, the module achieves high speed ADC clock and data isolation.

720210 High-speed 100 MS/s 12-Bit Isolation Module(Max. four(4) modules can be installed in a main unit.)
Module 720210

 

Rising waveform not completely captured

DL850 EX3 1

Rising waveform accurately captured

DL850 EX4 1

Example: Same inverter output waveform measured at 10MS/s and 100 MS/s

17 plug-in modules allow for flexible assorted measurements.

The lineup includes two new module types: A 16-CH Temp./Voltage Input Module, and a CAN & LIN Bus Monitor Module (DL850V only). All DL850 modules can be combined with measurement modules from the DL750 series products:


 

  • High-speed Voltage
  • High-precision voltage
  • Temperature
  • Acceleration
  • Logic Input
  • 16-CH Temp./Voltage - NEW
 
  • High Voltage
  • 16-CH Voltage
  • Strain
  • Frequency
  • CAN Monitoring (with the DL850V)
  • CAN & LIN Monitoring (for DL850V only) - NEW


Note: The firmware version 2.00 or later is required when using the 16-CH Temp./Voltage Input Module(720221) and/or CAN&LIN Bus Monitor Module(720241).

 

 

Advanced - Even More Measurement Points - Up to 128 CH of voltage input and 128 bits of logic input

The 16-CH Voltage Input Module (scanner type*) can measure at 10 kS/s sample rate even when using all 16 channels. With this module populating all 8 input module slots, the DL850 performs 128-CH voltage measurements.

 

 

The Logic Input Module supports everything from TTL levels, to high voltage contact closures at up to 10 MS/s*. With eight logic modules, the DL850 can monitor and capture 128 bits of logic.

Example: Measuring the startup sequence of a multi-output power source

Power supplies used in home computing electronics have many outputs, and it is necessary to control the sequences from output to output.  With a multichannel module, you are not limited to voltage measurements; a single unit can also measure everything from PC control signals to AC fan operation, individual component temperatures, and slow to high-speed signals.
 

DL850 EX19 7 Ch 1: AC Input Voltage
Ch 6: Supply Voltage
Ch 2: Reference Voltage
Ch 3: Reset Signal
Arrow
Ch 1: Fan Rotation
16-bit logic: Control Signals
4-bit logic: Serial Communication
DL850 EX20

Catch transients in durability with high-speed sampling - Dual Capture

To visualize long term trends in durability testing and other situations, data is typically acquired at low-speed sample rates. On the other hand, suddenly-occurring transitional phenomena should be captured at high-speed sample rates.

The "Dual Capture" feature resolves these conflicting requirements by recording at two different sampling rates.

  1. DL850 Dual Capture 1

    Zoom Waveform - You can record up to 5,000 phenomena of high speed trigger measurements (up to 100 MS/s) at a record length of 5-500 kPoints while taking trend measurements at up to 100 kS/s.

  2. Event Waveform -Displays the timing at which high speed "sub" waveforms are acquired

  3. Low Speed Main Waveform - Max: 100 kS/s Trend waveform displayed in a low-speed Roll mode

  4. Capture Waveform - Max 100 MS/s Capture transients with high speed trigger measurement

DL850 Chattering 1

Example: Parts Durability Testing

 

Parts used in automobiles and other transportation vehicles must be highly reliable. The "Dual Capture" function is very effective when performing vibration testing of connectors under varying temperatures.

 

  • Chattering is accurately captured at high-speed sampling
  • Check the frequency of occurence at low-speed sampling

Recall Past Waveforms - History Function

When you spot an abnormal phenomenon during repetitive high speed measurements, often the anomaly has disappeared from the screen by the time you press Stop.

Always active, the "History" function automatically divides the long memory into up to 5,000 "history waveforms" that can be redisplayed at any time.

 

 DL850 EX7 2
To extract abnormal waveformsArrow
DL850 EX8 1

Searching history waveforms
When you want to extract abnormal phenomena exclusively, you can perform condition-based searches of the history waveforms. You can create a rectangular zone on screen and extract only waveforms that pass through or do not pass through the zone. You can also extract data based on amplitude and other parameters. 

To check the history...
DL850 EX9
You can display all past waveforms, and view a list of acquisition times at min 1µs resolution

 

Key Point
The History function requires no action during measurement. You can recall data at any time after measurement has been completed. Once waveforms have been recalled, you can zoom locations of interest or perform parameter measurements.

Armed with an array of trigger functions

Simple & Enhanced Triggers

The DL offers easy-to-use "Simple" triggers, or lets you combine various "Enhanced" triggers for even more advanced capturing.

Enhanced trigger conditions are set up intuitively in advanced, easy-to-understand graphical user interface

 

DL850 EX10

 

 

  • Edge: Trigger on a single trigger source condition (rising, falling, rising/falling)
  • Time: Trigger at a specified time or fixed interval

Enchanced

 

  • A -> B(N): Trigger when condition B is true N times after condition A becomes true
  • A Delay B: After condition A becomes true, trigger the first time condition B becomes true after a set time has passed
  • Edge On A: Trigger on an OR condition of an edge trigger while the A trigger is true.
  • OR: Trigger if at least one trigger condition of multiple trigger sources is true
  • AND: Trigger if all trigger conditions of multiple trigger sources are true
  • Period: Trigger when a condition regarding the waveform period becomes true
  • Pulse Width: Trigger on a condition relating a pulse width condition being true with a specified time width condition.
  • Wave Window: Trigger when the signal passes outside of an real time template "Wave Window"

Example:"A Delay B" trigger setup screen (GUI)

 

 

 

Wave Window Trigger

The Wave Window trigger is useful for diagnosing typical power supply troubles such as momentary loss, sags, and surges. It can also detect frequency changes, voltage drops, and other phenomena, with support for AC waveforms of 40 to 1,000 Hz. A reference waveform (Real time template) is compared with the current waveform, and a trigger activates if the current waveform falls outside of the allowable range. The reference waveform is generated automatically from the previous waveform in real time.

 

DL850 EX11

*The Wave Window is not displayed on the display.

Action ON Trigger

To capture infrequently occurring phenomena, you can use an "Action ON Trigger" to perform multiple actions that are specified in advance when a trigger occurs.

 

DL850 EX12 1 You can specify "e-mail transmission" for immediate notification in a remote location when a phenomenon occurs.
  • Beep Sounds
  • Prints out screenshots
  • Saves waveform data
  • Saves Screenshots
  • Sends e-mails to a specified address

Superior Noise Rejection

DL850 EX16 1Excellent noise rejection performance is achieved through meticulous low-noise design. Floating voltage switching waveforms in inverter circuits can also be captured with precision.

 

DL850 EX13 1 Example: Measuring inverter gate signals
DL850 EX14 1
DL850 EX15 1
Model 701250 Voltage Input Module

 

Processes Noise Rejection and Executes Power Computations in Real Time - Realtime Math (/G3 option)

The DL850 is armed with a dedicated DSP (digital signal processor) for computations that enables between-channel math during waveform capture. These between-channel computations are powerful because they can be set up separately from fi lter computations. In addition to FIR, IIR, Gauss, and moving average digital fi lters, you can use maximum 35 equations such as arithmetic with coefficients, integrals and differentials, and higher-order equations.
 

  • Display any combination of measured and math waveforms (up to 16 total).
  • You can assign channels without modules.
Example: 3-Phase Power Computation
Power is calculated as the integral of the product of voltage and current over time (an average based on the period). Using the Realtime Math function, you can display 3-phase 4-wire power waveforms in real time. DL850 EX17 1


DL850 EX18 1

 

 

 

Key Point
Computations occur in real time even when in Roll mode. Computed waveforms can also be used to activate triggers.
Any vacant slots (CHs) can be utilized for the realtime math defi nition. Consequently, precomputation waveform and postcomputation waveform can be displyed simultaneously.

 

 

 

A wealth of functions gets you right to the waveform you want - User Defined Computation (/G2 option)

The DL comes standard with arithmetic, time shift, FFT, and other computations that enable you to display waveforms with offsets and skew corrections. And with user defi ned computations (/G2 option), you can create equations using a combination of differentials and integrals, digital fi lters, and a wealth of other functions.
 

User Defined Computation Setup Screen

DL850 EX21

 

Example: Amplitude Analysis Using FFT
With the User Defi ned Computation function(option) included, you can perform various-types of FFT analysis using two FFT windows. In applications such as vibration and shock tests, you can easily evaluate abnormal vibrations while simultaneously measuring other signals. DL850 EX22 1

 

Key Point
You can assign a log scale to the frequency axis.

Automatically extract waveform amplitude, frequency, and other parameters - Waveform parameter and statistical computation

Extract and display up to 32 parameters (amplitude, frequency, etc. including delay) simultaneously. Menus can be shown as lists of easy-to-read icons.

Statistical Computation  
The DL can automatically extract cycle waveforms and find the standard deviation and other statistics. Computations can be performed on history waveforms as well. DL850 EX23

Detect Abnormal Waveforms, Notify Users, and Determine Pass/Fail - Go/NO-GO Determination

The DL can determine whether waveforms or computed values of waveform parameters meet (GO) or do not meet (NO-GO) conditions that are specifi ed in advance. Upon judgment of the measured results, a pre-set action is performed and users are notified that an abnormal waveform was observed, along with the pass/fail
determination. This is a very useful function for such things as studying signals from manufacturing lines of electronic devices and tracing abnormal phenomena.
 

Example: Evaluating Motor Startup Characteristics 
DL850 EX24 1 Parameter measurement is taken of the time until reaching a reference RPM after motor start, and the subsequent GO/NO-GO (pass/fail) determination is made.

Synchronize Multiple Units Performing Simultaneous Measurements - IRIG input (/C20 option)

Unit IRIG Synchronized measurement across multiple DL850 units is made possible by inputting an IRIG time code signal.* The DL850/ DL850V's internal clock is also synchronized (locked) to the IRIG signal. Therefore, timing comparisons are highly precise even when continuously recording over long periods of time.
Key Point
You can make periodic observations remotely by connecting commercially available GPS receivers that have IRIG output and using the Time Trigger function.


Example: Synchronous measurements for large transport vehicles Simultaneously measuring both tips of airplane wings, or between railroad cars requires synchronizing multiple measuring instruments in time. With a single IRIG cable, the acquisition time of all data is made the same.

DL850 EX25

*IRIG (Inter-Range Instrumentation Group) started as an American military standard, and is now used in data recorders in the aerospace industry. The carrier frequency is a 1 kHz/10 kHz ASK (amplitude shift keying) modulating signal with a synchronizing precision of as high as 1 µs. DL850 support formats: A002, B002, A132, B122

 

The Flexibility of an External Hard Drive - External Hard Drive Interface (/HD0 option)

 

With an external hard drive interface, you can connect a commercially available eSATA standard hard drive. The DL can record to an external drive in real time just like it can with the built-in hard drive. After saving waveforms, you can switch the DL850/DL850V from the PC to the external drive and use the waveform data immediately.  Unit ESATA

 

Key Point
  1. Ensures Security  - Simply remove the drive after measurement to protect data. Or, keep restricted data only at the measurement site.
  2. Increases Capacity - If the external hard drive becomes full, you can simply switch to a new one (requires a restart).
  3. Hi-Speed Data Transfer - A data can be transfered at high speed between a PC and a hard drive.
* The external hard drive is an option when specifying the internal hard drive.
* The speed of realtime hard drive saving depends on the performance of the hard drive.

 

Check the Relationship between Hysteresis and Phase - XY Display Function

You can confirm the relationship between two signals using the X-Y display. This can be applied to measurements such as the phase angle of two sine waves.

You can select four combinations on the X and Y axes, and therefore display multiple X-Y waveforms simultaneously and find relationships between them.

Simultaneous observation of X-Y waveforms and normal T-Y waveforms (waveform display using voltage and time axes) is also possible.

Example: Computing dynamic BH characteristics of a magnetic substance On the DL850 you can measure voltage and current, then analyze hysteresis of magnetic flux density B and magnetic field strength H. Energy loss generated by magnetostriction can be evaluated by measuring dynamic BH characteristics.

DL850 EX26 2

Magnetic flux density: B = Integ (C1) / (K1*K2)
Magnetic field strength: H = C2*K1 / K3
C1: voltage, C2: current
K1: number of turns, K2: cross sectional area
K3: magnetic circuit length

Snapshots

With the push of "SNAP SHOT" key, you can save a "snapshot" of the measured waveform (the waveform displayed on screen). The waveform remains saved even if you restart measurement, therefore you can easily compare the snapshot with any newly measured waveforms. Snapshots can also be saved and loaded as files.

DL850 EX27
You can compare waveforms from varied conditions
Example: Comparison of a snapshot waveform (white) with another waveform

Web Server

DL850 EX28
You can operate controls and acquire screen images with a Web browser - no special software required on the PC.
The Web Server function displays the screen of any networked DL850/DL850V on a PC via Ethernet. From this screen, you can remotely start or stop measurement, update the DL's display, and take snapshots (capture images) of the screens.

Multilanguage Support

DL850 EX28 Adhesive front panel key label sheets ("panel sheets") are available in eight different languages. Multilanguage support is also provided for menus and error messages.

Saving Screen Images and Displaying Thumbnails

DL850 EX30
Screen images saved to storage media are shown on screen as thumbnails for easy identification.

Screen images can be saved to a specifi ed storage medium in PNG, JPEG, or BMP format. These screen images can be imported into reports or other PC-created documents.

Enhanced capabilities for vehicle design and development such as CAN & LIN Buses monitoring

DL850V 1

The DL850V ScopeCorder Vehicle Edition can display CAN- and/or LIN-protocol communication data as trend waveforms on the display by using the CAN Bus Monitor Module (720240) or CAN & LIN Bus Monitor Module (720241(*1) ). It can also trigger on decoded waveforms. By identifying the correlation between communication data on the vehicle-installed LAN and analog data such as voltage, temperature, and sensor signals or the ECU’s control logic signal, a vehicle’s overall LAN system can be evaluated. Furthermore, with the /DC option, the DL850V can be driven by DC power such as the vehicle’s battery, in addition to ordinary AC power.

(*1): The CAN & LIN Bus Monitor Module (model: 720241) is supported by the main unit firmware ver. 2.00 or later.

Utilization of Vehicle-installed Network Definition Files (CAN DBC, LIN LDF)

Data to be acquired using a bus monitor module (720240 or 720241) can be specified not only in digital code (hexadecimal or numeric), but also loaded from a network definition file (CAN DBC or LIN LDF).

Example of comparison and verification of a measured signal and CAN bus signal
You can trend the physical value of CAN bus data and the corresponding measured waveforms on the same screen at once. For example, an ignition switch ON/OFF signal, a CAN signal corresponding to that command, and an actual signal measured by a pressure sensor, etc. can be displayed and checked on the same screen, to verify the correlation of those signals.
 



 

Support for both AC and DC power (/DC option, DL850V only)

 

  • Low power consumption of 60 - 120 VA (typ.)
  • Low noise

The DL850V Vehicle Edition can be driven by a 12 V DC battery, vehicle’s cigarette lighter, or ordinary AC power. (We provide accessories for DC driving; see the list of accessories at the end of the catalog.) 

Photo: DL850V/DC option model
 

  1. EXT I/O - GO/NO-GO determinations can be output, and you can perform control based on start/stop and other external signals
  2. External clock I/O (EXT CLK IN) - Perform sampling timed to an external signal (up to 9.5 MHz).
  3. External Trigger Input (EXT TRIG IN)
  4. External Trigger Output (EXT TRIG OUT)
  5. Video signal output (VIDEO OUT) - Confirm waveforms on an analog RGB (XGA) external display.
  6. USB-PC Connection Terminal -  Enables control from a PC.
  7. Ethernet 1000BASE-T - Comes standard
  8. GP-IB (optional)
  9. IRIG (optional*2) - Inputting an external time signal lets you synchronize multiple DL850s.
  10. External hard drive IF (optional*1) - Connect an eSATA standard hard drive.
  11. SD Card Slot - SD, SDHC compliant, comes standard
  12. USB Peripheral Connection Terminals - Supports USB storage, keyboards, and mouse input. 


*1 Built in hard disk and external hard disk IF are not available together.
*2 The GP_IB is also available when IRIG (/C20) option is specified.

Overview:

There are several factors for a user to consider when using an IEPE accelerometer, particularly when used with newly available integrated signal conditioner/data acquisition process. Correctly managing these factors will help the user avoid erroneous data from their IEPE accelerometer and ensure the quality of the data measurement is at the level they expect and require.

Industries:
Overview:

With the increased demand in electric-hybrid vehicles, the electromechanical designs of in-vehicle systems are becoming more sophisticated and there has been a demand shift towards high efficiency brushless direct current motor (BLDC) implementation. Think of motorized seat adjustment, electric window, power steering, HVAC fans, pumps, etc. In many of these systems various types of motors are used as actuators; more specifically, 3-phase BLDC motors are gaining popularity as they provide these important advantages:

  • Improved speed vs torque characteristics
  • High dynamic response
  • High efficiency
  • Extended speed ranges
  • Long operation life
Industries:
Technical Article
Yokogawa VIP Suite for Automotive Design Engineers  
(Yokogawa VIP Suite for Automotive Design Engineers)
Edition 2017
Industries:
Technical Article
Yokogawa VIP Suite for Power Measurements  
(Yokogawa VIP Suite for Power Measurements)
Edition 2018
T&M Magazine no 3
(T&M Magazine no 3 (Feb 2015))
Edition 02.2015
T&M Magazine ed. 5 - ScopeCorders (Oct 2017)
(T&M Magazine ed. 5 - ScopeCorders (Oct 2017))
Edition 10.2017
Brompton goes electric  
(Brompton Bikes)
Edition 2019
Overview:

As a respected pioneer in folding bikes, Brompton’s first foldable e-bikes was eagerly anticipated. However, to develop such high-performance e-bikes engineers at Brompton needed to perform comprehensive dynamic testing to achieve rider – bike harmony.

 

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making

Top