Modules

Yokogawa Industrial Modules

  • Isolation Modules
  • Voltage modules
  • Temperature Input Module
  • Strain Input Modules 
  • Frequency Modules 
  • Logic Input Modules
  • Auxillary Modules, and more
  • 2-Channel Analog Input
  • 200 MS/sec, 14-Bit
  • 40 MHz Bandwidth
  • Max. Input Voltage (DC + ACpeak): 1000V / 200V
  • 4-Channel Analog Input
  • 10 MS/sec, 16-Bit
  • 3 MHz Bandwidth
  • Max. Input Voltage (DC + ACpeak): 600V / 200V
  • 2-Channel Analog Input
  • 100 MS/sec, 12-Bit
  • 20 MHz Bandwidth
  • Max. Input Voltage (DC + ACpeak): 1000V / 200V
  • 2-Channel Analog Input
  • 10 MS/sec, 12-Bit
  • 3 MHz Bandwidth
  • Max. Input Voltage (DC + ACpeak): 600V / 200V
  • 4-Channel Analog Input
  • 1 MS/sec, 16-Bit
  • 300 kHz Bandwidth
  • Max. Input Voltage (DC + ACpeak): 600V / 200V
  • 2-Channel Analog Input
  • 1 MS/sec, 16-Bit
  • 300 kHz Bandwidth
  • Max. Input Voltage: 1000V (Direct Input)
  • 16-Channel
  • Isolated (GND-Terminal), Non-Isolated (CH-CH)
  • 10 kS/s on All Channels or 200 kS/s Single-Channel
  • Max. Voltage Per Channel (DC + ACpeak): 42V
  • 2-Channel
  • 12 Thermocouple Types Supported
  • 2-Channel
  • Universal Module (with Anti-Aliasing Filter)
  • 12 Thermocouple Types Supported
  • 2-Channel
  • 12 Thermocouple Types Supported
  • High Sensitivity Range (1 mV) & Low Noise (±4 µVtyp)
  • 2-Channel
  • 16-Bit, 125 S/s (Voltage) & 125 S/s (Temperature) Sample Rate
  • 16-Channel Voltage/Temperature Input Module
  • Use with 701953 Scanner Box
  • 2-Channel
  • Strain Module, Type NDIS
  • Use with 701955 or 701956 NDIS Bridge Head
  • 2-Channel
  • Strain Module with Shunt Calibration, Type DSUB
  • Use with 701957 or 701958 DSUB Bridge Head
  • 2-Channel
  • Selectable Anti-Aliasing Filters
  • Direct Accelerometer Excitation and Input
  • 2-Channel, Isolated
  • 1 MS/s Sample Rate
  • 420V Max Input with 10:1 Probe
  • 0.01 Hz to 500 kHz Measurement Frequency
  • Trend and Trigger on Frequency, RPM, RPS, Period, Duty Cycle, Pulse Width, Pulse Integration, and Velocity
  • Two Ports, 8 Bits Each (16 Logic)
  • Display Logic as Waveforms at 10 MS/s
  • Compatible with 700986, 700987, 702911, 702912 Logic Probes
  • Decode SENT (SAE-J2716) Protocol Signals
  • Display Physical Quantities from Output Sensors
  • Applicable to ScopeCorder Vehicle Edition
  • Up to 60 Channels Per Port x2 Ports
  • Decode CAN, CAN FD, and LIN
  • Extract and Trend Serial IDs as Analog Waveforms
  • Applicable to ScopeCorder Vehicle Edition
  • External scanner box for 720221 module
  • Voltage or temperature measurement (scanner method)
  • Thermocouple (K, E, J, T, L, U, N, R, S, B, W, Au-Fe-chromel)

A Power Module consists of one Voltage Module- Model 760811, and one Current Module- 760812 or 760813.

A Power Module consists of one Voltage Module- Model 760811, and one Current Module- 760812 or 760813.

A Power Module consists of one Voltage Module- Model 760811, and one Current Module- 760812 or 760813.

Sensor and voltage measurement module (up to three modules can be installed) Auxiliary (AUX) module

  • 2-Channel Analog Input
  • 1 MS/sec, 16-Bit
  • 3 MHz Bandwidth
  • Max. Input Voltage (DC + ACpeak): 600V / 140V
  • High Sensitivity Range (10 mV), Low Noise (±100 µVtyp)
  • 2-Channel Analog Input
  • 10 MS/sec, 12-Bit
  • 3 MHz Bandwidth
  • Max. Input Voltage (DC + ACpeak): 600V / 200V

760901 30A High Accuracy Element. Includes external sensor input.

760902 5A High Accuracy Element. Includes external sensor input.

  • AQ2200-112 Light source module
  • High output level stability performance
  • AQ2200 Multi-Application Test System

High Stability reference laser light sources for DWDM channel measurements. The one or two channel modules are part of an integrated optical device testing solution for the AQ2200 series frame controller platform.

Ideal for measuring output power of transmission equipment and optical fiber amplifiers.

  • AQ2200-232 Optical Sensor Head (Large diameter detector, 800 to 1700 nm)
  • AQ2200-242 Optical Sensor Head (Large diameter detector, 400 to 1100 nm)
  • AQ2200-202 Interface Module (2-channels)
  • High performance optical sensor heads and interface module 
  • AQ2200-312 Variable Optical Attenuator Module from Yokogawa Test&Measurement 
  • Small, lightweight variable optical attenuator providing low insertion loss
  • SM, GI50, and GI62.5 fiber optic attenuator types available

With built-in optical power meter for monitoring power
Compact and lightweight optical variable attenuator.
SM, GI50 and GI62.5 optical fiber models available.

  • AQ2200-411 Optical Switch Module 
  • Superior switching reproducibility
  • Compact optical switches
  • SM, GI50 and GI62.5 optical fiber models available
  • AQ2200-412 Optical Switch Module
  • Superior switching reproducibility
  • Compact
  • SM & GI50 optical fiber models available
  • AQ2200-421 Optical Switch Module
  • Superior switching reproducibility
  • Compact optical switches
  • SM, GI50 and GI62.5 optical fiber models available

The AQ2200-642 reduces the complexity and cost of 10G optical transceiver testing by combining bus and power control features into the same mainframe that performs Signal Generation, BERT and Optical testing.

The AQ2200-212 is single channel sensor module with an analog output port.

Increase your testing power and capability with the AQ2200-222 sensor module.

Current Sensor Element
Firmware version 3.01 or later of WT5000 main frame is required.