DLM5000HD High-Definition Oscilloscope

Precision in Every Detail

The DLM5000HD Series High-Definition Oscilloscope is the latest addition to the Yokogawa Test&Measurement oscilloscope line-up that takes you beyond eight channels.

Adaptability is key in the development of high-performance and intelligent power semiconductor technologies and mechatronics in modern electric vehicles, motor controls, and energy efficient electronic designs. With up to 16 bits high resolution, best-in-class startup speed, the ability to support measurements up to 16 channels, high noise immunity for harsh environments, and more, the four-to-eight channel DLM5000HD Series enables easy touch navigation through a wealth of analysis features.

Setting a New Standard for High Definition

  • 4 or 8 analog channels, 16-bit logic + optional additional 16-bit logic
  • Bandwidth: 350 or 500 MHz
  • Sample Rate: up to 2.5 GS/s
  • Vertical resolution: 12 bit
  • High resolution mode: up to 16 bit
  • Measurement memory: up to 1 GigaPoints
  • History waveforms: up to 200,000 triggers
  • Simultaneous Multi-Channel Measurements: Up to 32 bit logic + 8 channels
    • Up to 16 channels with two connected DLM5000HDs via DLMsync
    • IEEE1588 Synchronous Support
  • Highly-Responsive, Intuitive 12.1in Touchscreen
    • with Traditional Oscilloscope Control Panel
  • Superior Noise Immunity
  • Logic and Serial Bus Analysis
  • Additional Math Channels
  • Extensive Voltage Ranges
  • Compact, Light, Portable

Key Specifications

12 to 16-Bit High Resolution
Compared to traditional 8-bit oscilloscopes, the DLM5000HD measures 12-bit vertical resolution all the time. With its high definition, resolution improves up to 16-bits, providing 16x more detail than existing high-definition oscilloscopes. Its high-resolution mode enables detailed measurement of events such as ringing and overshoot with impressive accuracy.

Multi-Channel Measurement Up to 16 Channels
A single DLM5000HD measures up to eight channels simultaneously, while connecting two instruments extends synchronous measurement up to 16 channels to enable evaluations via a single test.

Multi-Channel Measurement Up to 16 Channels | DLM5000HD Mixed Signal Oscilloscope | Yokogawa Test&Measurement
 

Wide Bandwidth Measurement
Momentary phenomena such as overshoot at the rise of a high-speed inverter cannot be verified with low bandwidth oscilloscopes. The DLM5000HD combines a wide bandwidth of up to 500 MHz with a sample rate up to 2.5 GS/s.

Up to 2.5 GS/s, Up to 1 G Points Memory
The DLM5000HD has a memory capacity up to 500 M points in single mode and 125 M points in repeat mode for waveform capture that allows you to observe waveforms with very few omissions when all channels are used.

Maximum Record Lengths (Points)
Maximum Record Lengths (Points) | DLM5000HD Mixed Signal Oscilloscope | Yokogawa Test&Measurement
*1: At odd-numbered channels   *2: DLM5000HD only

Large Selection of Triggers
The DLM5000HD’s extensive triggers can trigger on feature points to extract waveforms of interest and store them in the history memory. Display a list of history waveforms to see intervals between triggers or line up several waveforms to identify trends around feature points to determine how often or under what conditions a characteristic waveform occurs. 

Stable and Reliable Purpose-Built System

Stable and Reliable Purpose-Built System | DLM5000HD Mixed Signal Oscilloscope | Yokogawa Test&Measurement

12.1in Intuitive, Highly-Responsive Touchscreen
The large 12.1in intuitive and highly-responsive touchscreen is useful for observing analog signals in detail and displaying information for debugging like parameters, zoom, XY display, and FFT analysis results.

Compact, Light Weight, and Portable
Despite boasting a large screen with multichannel inputs, the DLM5000HD has a portable, thin, and lightweight design.

Quick Startup
The DLM5000HD starts up from OFF to waveform display in twelve seconds for a quicker start on projects.

Link with a PC
It is often more effective and efficient to perform analysis using a PC because of its high CPU processing power. This can be accomplished with the DLM5000HD through integration with the IS8000 Integrated Test and Measurement Software Platform for  multiple waveform and power measurement results and powerful analysis capabilities.

DLM5000/DLM5000HD Comparison

FEATURE DLM5000 DLM5000HD
 

DLM5000 Mixed Signal Oscilloscope | Yokogawa Test&Measurement

DLM5000HD High-Definition Oscilloscope | Yokogawa Test&Measurement

Vertical Axis Resolution 8 bit (High-Resolution 12 bit) 12 bit (High-Resolution 16 bit)
Memory Size < 500 M points < 1 G point
History Waveforms < 100,000 < 200,000
IEEE1588 Synchronous Support Requires Additional Master Machine Master Function Available (/CY)

 

 

 

Key Features

History and Search
Automatically save previously captured waveforms with the DLM5000HD series, up to 200,000 previously captured waveforms can be saved in the acquisition memory. Display one or all of the previously captured waveforms (history waveforms) on screen and perform cursor measurement, computation, and other operations. Users can analyze rarely-occurring abnormal signals even when an appropriate trigger condition is difficult to find because its waveform shapes are not constant. Multiple intuitive search methods are also available. For example, you can specify a rectangular zone that captures a part of a waveform on the screen, a zone that covers an entire measured waveform, or a polygonal zone. If you know a value of interest, such as an abnormal value of voltage or pulse width, you can search history waveforms using waveform parameters.

Captured Waveforms History Function | DLM5000HD Oscilloscope | Yokogawa Test&Measurement
 

Zoom and Search
Multi-channel waveforms captured in the long memory need to be zoomed in vertically and horizontally for detailed viewing. The touchscreen plus dedicated zoom keys and knob allow you to quickly zoom in on aspects you wish to see. You can display two zoomed waveforms with different time axis scales at the same time and use Auto Scroll to sweep the zoom window across the waveforms automatically. The ability to zoom in on two distant locations at the same time (like “cause” and “effect” of an event) or to display them with different zoom factors is very useful for software debugging. Users can also search using multiple criteria to automatically find and zoom into features in the waveform for further inspection. The locations of the found waveforms are marked on screen.

Waveforms Zoom and Search | DLM5000HD High-Definition Oscilloscope | Yokogawa Test&Measurement
 

Logic Signal Measurement and Analysis
Equipped with 16 bit logic input as standard. With the /L4 and /L32 options, up to 32 logic signals can be measured. Bus/State display and optional DA calculation functions (useful for AD/DA converters evaluation) are also provided.

Logic Signal Measurement and Analysis | DLM5000HD High-Definition Oscilloscope | Yokogawa Test&Measurement
 

Filters
Real-time filters with optimum noise reduction support a wide range of frequencies from 8 kHz to 200 MHz. Each channel has 14 low pass filters available with cutoff frequencies from 8 kHz to 200 MHz and waveforms are filtered prior to storage in memory. These real-time filters allow for stable triggering of superimposed noise signals.

DLMsync (/SY or /SYN)
Connecting two DLM5000HD Series models (with /SY or /SYN option) with a dedicated cable (701982) enables synchronous measurement up to 16 channels. Captured waveforms display on each unit, triggers operate in common, and common items (record length, sample rate, acquisition settings, horizontal axis scale settings) are linked like a single 16-channel oscilloscope. Connect four-channel models for possibilities. Two synchronized instruments become linked and some operations are shared between the main unit and the sub unit. For example, if you zoom in on a waveform on the main or sub unit, the corresponding waveform on the other unit will automatically get zoomed in at the same spot. As measurement data can be output in batches, 16 channels can be checked at once in combination with the IS8000 integrated software platform.

IEEE1588 Integrated Measurement Master
The DLM5000HD can be set as the master unit for time-synchronized measurement using IEEE1588. This function connects measuring instruments in a LAN network to each other without a dedicated cable or complex settings typically required for synchronization, which allows users to start synchronized measurements easily. If using a network HUB, be sure to use an IEEE1588-supported version.  All measured data and results can be integrally analyzed on the same time axis on the IS8000 integrated test and measurement software platform.


Other Functions for Improved Operational Efficiency

Functions for Improved Operational Efficiency | DLM5000HD High-Definition Oscilloscope | Yokogawa Test&Measurement

Multi-Channel Measurement Applications

High Voltage Switching Motor/Inverter Circuits Development
The high-definition oscilloscope DLM5000HD is ideal for measuring fast switching of inverters. It measures eight channels simultaneously up to 2.5 GS/s with bandwidths up to 500 MHz and provides high-precision analysis with 12-bit resolution. In addition, DLMsync enables uncomplicated connection of two DLM5000HD Series models to allow evaluation tests to be completed all at once through multi-point measurements. The SW Loss Math Function is effective for inverter characterization and provides powerful analysis support. A full line of accessories for high voltages is also available.

High-Voltage Switching Motor/Inverter Circuits Development | DLM5000HD High-Definition Oscilloscope | Yokogawa Test&Measurement
Examples include measuring three-line voltages and three-phase currents of a three-phase motor simultaneously and measuring gate control signals of six SiCs in an inverter at the same time.
 

Automotive Electronic Control Unit and Mechatronics Embedded Device Development
Digital waveform analysis using logic inputs alone cannot reveal anomalies such as voltage drift, noise, distortion or ringing, and measure rise-fall times. Electronic control unit (ECU) testing requires stringent examination of all digital waveforms and analog input channels are best for this job. Numerous I/O analog, digital, and serial-bus waveforms surrounding the ECU must be measured. The DLM5000HD offers ample channel-count and architecture to monitor eight analog channels and up to 32-bits of logic input while simultaneously performing protocol analysis such as UART, I2C, SPI, CAN, CAN FD, LIN, CXPI, PSI5, and FlexRay.

Automotive Electronic Control Unit and Mechatronics Embedded Device Development | DLM5000HD High-Definition Oscilloscope | Yokogawa Test&Measurement
Examples include measuring controller I/O signals and serial bus signals simultaneously and measuring analog behavior of both logic and serial bus signals.
 

Power Conditioning Systems Evaluation
When evaluating power conditioning systems, measuring for long periods of time at low sampling rates is required to determine overall power efficiency. However, there are sometimes situations where a user may want to capture events at a high sampling rate, like when a high load is applied. The DLM5000HD employs a IEEE1588 master function with highly-accurate time synchronization with the WT5000 Precision Power Analyzer, along with other IEEE1588-supported models, for easy measurement synchronization. Capture microseconds-long events without omissions while the WT5000 accurately measures power efficiency over a long period of time.

Power Conditioning Systems Evaluation | DLM5000HD High-Definition Oscilloscope | Yokogawa Test&Measurement

Serial Analysis Function Options (/F1 to /F6, /F01 to /F06)

UART (RS232) /I2C/SPI/CAN/CAN FD/LIN/FlexRay/SENT/CXPI/PSI5 Airbag
Dedicated trigger and analysis options are available for various serial buses of both in-vehicle and embedded systems. Logic input can also be used for I2C/SPI/UART/SENT. When not necessary to observe waveform quality of a bus, decoding or analysis using logic inputs is possible.

Unique Auto Setup
Yokogawa Test&Measurement’s proprietary Auto Setup function automatically analyzes the input signal or captured waveforms and complex parameters such as bit rate and threshold level and selects the optimal settings in seconds. This saves time and is a powerful debugging feature when bit rate and other parameters are unknown.

Simultaneous Analysis (Up to Four Buses)
Perform high-speed simultaneous analysis on up to four different serial buses operating at different speeds. Extensive search capabilities enhance the usability and allow users to find specific data in very long memory. Use dual-zoom means view different buses and debug alongside each other.

Simultaneous Analysis of Up to Four Buses | DLM5000HD High-Definition Oscilloscope | Yokogawa Test&Measurement
Four-bus list display (top right image) and waveform display and decode results (bottom right image).

User-Defined Math Option (/G2 or /G02)

Equations can be arbitrarily created using a suite of operators such as trigonometric and logarithmic operators, integration and differntiation, pulse width operators, phase measurement, and digital-to-analog conversion.

Power Supply Analysis Option (/G3 or /G03)

Switching Loss Analysis: Calculate switching loss [ V ( t ) × i ( t ) ] over long test cycles utilizing the long built-in memory. A wide variety of switching loss analyses are supported, including turn-on/off loss calculation, loss including continuity loss, and loss over long cycles of 50 Hz/60 Hz power line. Power Parameter Measurement: Measure power parameters automatically for up to four pairs of voltage and current waveforms, such as active power, apparent power, power factor, and more. Cycle statistics and history statistics can also be calculated.

701988 Logic Probe 100 MHz / 8-bit

701988 (PBL100) Logic Probe

701989 Logic Probe 250 MHz / 8-bit

100 kΩ input resistance, toggle frequency of 250 MHz

701937 Passive probe 600V / 500 MHz

500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m Supplied standard with DLM3000, DLM5000, DLM5000HD series

701949 Miniature Passive Probe 400V / 500 MHz

500 MHz, 10:1, 400 Vrms, 1.3 m
For DLM3000, DLM5000, DLM5000HD series

702907 Passive Probe 1000V / 200 MHz

200 MHz, 10:1, ±1000V (DC + ACpeak) CAT II, 2.5 m
Operating environment: −40 to +85°C (no condensation)
For DLM3000, DLM5000, DLM5000HD series.

700939 Active FET Probe 10V / 900 MHz

  • 700939 Active FET Probe
  • 900 MHz Active FET Probe Circuit
  • 10:1, ±10 V (DC + ACpeak) FET Input Active Probe
  • 1.5 m

 

701944 High Voltage Passive Probe 1000Vrms / 400 MHz

  • 701944 High Voltage Passive Probe 1000Vrms / 400 MHz
  • For DL1700, DLM2000-6000, DL6000, DL9000, SB5000 series

701945 High Voltage Passive Probe 1000Vrms / 250 MHz

  • 3m High Voltage Probe (oscilloscope)
  • DC to 250 MHz bandwidth 
  • 100:1 attenuation 
  • Max Input 1000 Vrms CAT II 4000 V transient over-voltage CAT O

701977 Differential Probe 7000 V / 50 MHz

  • 701977 Differential Probe for Oscilloscope 7000 V / 50 MHz
  • 50 MHz, 1000:1 / 100:1, Max.
  • Differential Voltage: 5000 Vrms and 7000 Vpeak or less

701978 Differential Probe 1500 V / 150 MHz

  • 701978 Differential Probe for Oscilloscope 
  • 1500 V / 150 MHz
  • 500:1 / 50:1
  • Max. Differential Voltage:±1500 V (DC + ACpeak)

701924 Differential Probe 25V / 1 GHz

  • 701924 Differential Probe
  • 1 GHz, 50:1, Max. Differential Voltage: ±25 V (DC + ACpeak), Probe Power: dedicated probe interface

701925 PBDH0500 Differential Probe 25 V / 500 MHz

500 MHz, 50:1, Max. Differential Voltage:±25 V(DC+ACpeak)
Probe Power:Dedicated probe interface

701927 Differential Probe 1400V / 150 MHz

  • 701927 Isolated Differential Probe
  • 150 MHz 
  • Max. Differential Voltage: ±1400 V (DC + ACpeak) at 500:1
  • Probe Power: dedicated probe interface For DLM, DL, and SB5000 series

701917 Current Probe 50 MHz / 5 ARMS

  • 701917 oscilloscope current probe
  • Frequency bandwidth: DC to 50 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

701918 Current Probe 120 MHz / 5 ARMS

  • Yokogawa 701918 Current Probe
  • Frequency bandwidth: DC to 120 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

701929 Current Probe 50 MHz / 30 ARMS

  • 701929 Current Probe 50 MHz / 30 ARMS
  • Front-end powered
  • Auto-recognized
  • DLM2000-4000, DL/DLM6000, DL/DLM9000, SB5000

701928 Current Probe 100 MHz / 30 ARMS

  • 701928 scope current probe
  • Front-end powered
  • Recognized automatically
  • Adjust zero position from operation of DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000. SB5000 

701930 Current Probe 10 MHz / 150 ARMS

  • 701930 Current Probe 10 MHz / 150 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701931 Current Probe 2 MHz / 500 ARMS

  • 701931 Current Probe 2 MHz / 500 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

702915 Current Probe 50 MHz/ 0.5 ARMS, 5 ARMS, 30 ARMS

  • 702915 Current Probe
  • Freq bandwidth: DC to 50 MHz
  • Maxi continuous input range: 0.5 Arms/ 5 Arms/ 30 Arms
  • Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

702916 Current Probe 120 MHz/ 0.5 ARMS, 5 ARMS, 30 ARMS

Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 0.5 Arms/5 Arms/30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments

AC/DC Split Core Current Sensor CT1000S

Measure high currents without disassembling existing cabling. Compatible with power analyzers and waveform measurement instruments.

701934 External Probe Power Supply

  • 701934 External Probe Power Supply
  • Power supply for current probes, FET probes, and differential probes
  • Supplies power for up to four probes, including large current probes

701936 Deskew correction signal source

  • 701936 Deskew Correction Signal Source
  • Improve switching-loss measurements by deskewing
  • Accommodates both clamp-on current probes and through-type ‘CT' Current Transformers

B9852ES Logic Probe IC Pin Clips

  • B9852ES Logic Probe IC Pin Clips
  • Attach to tips of logic probe (701988 or 701989) or mini-clips (B9852CR)
  • Clip contiguous 0.5-mm pitch terminals
  • 10 clips included

701909 Logic probe accessory kit

Logic probe accessory kit for use with 701989.

700971 Mini clip converter

A clip set designed for 701937, 701938, 701939, 701943 (PB500) and 700939

700972 BNC adapter

  • 701937,701938, 701939, 701943 (PB500) and 700939

701901 BNC to Safety Banana 1.8m Cable, 1:1

  • 701901 BNC to Safety Banana 1.8m Cable, 1:1
  • 1000 Vrms-CAT II, 1.8 m long
  • Safety BNC(male) to safety banana(female)
  • 701959, 701954, 758921, 758922, 758929

701906 Long Test Clip

Set contains one black and one red clip
1000 Vrms-CAT II
2 pieces (red and black) in 1 set 
Connected to the 758933, 758917, or 701901
Length: 0.3m
Applicable for DL750/DL750P, SL1000, SL1400

701948 Extension Clip Accessories

Connected to the 700929, 701947
Maximum input voltage: 1,000V (DC + ACpeak)
Length: 0.26m/0.3m/0.4m
Applicable for DL750/DL750P, SL1000, SL1400

701954 Large Alligator Clip (dolphin type)

Set contains one black and one red clip.
1000 Vrms-CAT II.

758921 Fork terminal adapter

  • 758921 Fork Terminal Adapters
  • For fitting a 4mm banana plug to a fork terminal
  • One black and one red clip
  • 1000 Vrms-CAT II

758922 Small Alligator-Clip Adapter 300V

Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.

758929 Large Alligator Clip Adapter 1000V

  • Yokogawa 758929 Alligator Clip Adapter 
  • Rated at 1000V
  • Attaches to 758917 test leads
  • Sold in pairs black/red

758917 DMM Measurement Lead Set

  • Set of 0.8m long red and black multimeter test leads
  • Used in combination with a pair of optional 758922 or 758929 alligator-clip adapters
  • 1000 Vrms, 32 Arms CAT II

761953 Safety Terminal Adapter Set

Two adapters to a set for 5 A current
(screw-fastened type using B9317WD)

366924 BNC to BNC 1m Cable

  • 366924 BNC to BNC cable for oscilloscope 
  • 1m BNC wire
  • Simultaneous measurement with 2 units
  • Input external trigger signal

366973 Go/No-Go Cable

This cable is used to connect an external device, however, do not use this cable for purposes other than DL750/1600/1700/1700E/7400 GO/NO-GO judgement.

366923 BNC to T Adapter

T-adapter for BNC connectors. Use for circuits having voltage levels no greater than 42 V.

366945 Printed circuit board adapter

For 701937, 701938, 701939, 701943 (PB500) and 700939.
Quantity of 1 unit: 10

366946 Solder-in adapter

For 701937,701938, 701939, 701943 (PB500) and 700939 Standard accessories include: Adapter, red wire (3), black wire (3)

B9988AE Printer paper

Quality paper for the DLM2000 /DLM4000 /DL850 /DL6000 /DL9000 and DL750

701919 Probe Stand

  • 701919 oscilloscope probe stand
  • Flexible arm, heavy base to hold and stabilize 8-13mm probes
  • Can simplify circuit board testing

B8059GG Soft case

Soft Case for Accessories

B9852CR Mini Clip Passive Probe Tip

A clip set designed for the 700988, 700960 and 701940 probes.

701982 Connection cable

  • DLM Micro USB Cable
  • 701982-01 Connection cable for DLM 1.0 m
  • 701982-02 Connection cable for DLM 2.8 m
Overview:
  • Construction and verification of SENT communication system
  • Accurate, reliable data transmission at low cost
Industries:
Overview:

While accurate rise time measurements have become easier to make, it remains, nonetheless, quite easy to overlook error contributions due to not only the oscilloscope but also the probe. And, while the error contributed by a scope's finite step-response (rise time) is often accounted for, that contributed by the probe is often overlooked.

Overview:

DLM5000_Simultaneous_analysis_of_eight_CAN_buses

Industries:
Overview:

Frequency to Voltage Conversion   Problem: A transducer produces a sine-wave output dependant on the voltage-input; here is how to decode that output with a scope or a ScopeCorder.  For 3kV input, the transducer ...

Overview:

The free software DL-GATE can be used for the following products only:DL1700E seriesDL7400 series (firmware version after 1.32)DL1600 series (firmware version after 1.13)DL750 series (firmware version after ...

Overview:

The DLM series oscilloscopes (DLM5000HD, DLM5000, and DLM3000) and ScopeCorders (DL950, DL350) provide the CAN Bus symbolic decode analysis function. For DLM series, an overlay function displays the CAN packet structure directly below the time domain waveform.

Webinars

    Overview:

    With ongoing innovations in motor and inverter technologies seeking to advance global decarbonization objectives in the automotive industry, it’s crucial that engineers have a thorough understanding of how to properly analyze these systems.

    This complimentary webinar provides engineering professionals involved in motor and control system development with insights that enable data benchmarking and troubleshooting issues related to energy efficiency in electric vehicle (EV) powertrains.

    Key webinar topics include:

    • Establishing baselines for system efficiency
    • Conducting inverter control signal analysis at the systems level
    • Identifying critical measurements for benchmarking inverter input, inverter output, and motor output
    • Analyzing motor control signals, including torque control variables, positional sensors, and pulse-width modulation (PWM), as well as torque measurements

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making