Why are the Measured Values for VAR and ΣVAR Unstable?

Check the Synch Source and Frequency Filter settings

  1. When a single-phase signal being measured fluctuates around power factor of 1.

    Slight fluctuations in the measured values of voltage, current, and power can cause a large instabilities in the calculation of Var (around power factor 1) and ΣVar. In this case, to stabilize the measured values of voltage, current, and power, check the sync source setting and zero cross filter setting.
  2. When a three-phase signal being measured fluctuates around a phase angle of 30 degrees.

    In the case of zero cross filter (frequency filter), three-phase three-wire, or 3V3A wiring, in the vicinity of phase angle 30°, input to the power meter is the same condition as the above single-phase measurement. For details, see The power, power factor, and phase angle of each input element do not match when measuring the balanced three-phase load. Therefore, slight fluctuations in the measured values of voltage, current, and power or instable leading/lagging detection can cause large instabilities in the calculation of Var and ΣVar.

Produtos e Soluções Relacionadas

Precision Power Analyzer WT3000

With 0.02% accuracy and 1MHz bandwidth, the WT3000 delivers where the highest precision measurements are required. It is the industry standard for R&D work on inverters, motor drives, lighting systems and electronic ballasts, UPS systems, aircraft power, transformer testing, and other power conversion devices.

PZ4000 Power Analyzer

The PZ4000 is designed for High Frequency Power Measurements as well as Transient Power Measurements. Its real-time acquisition system can perform cycle-by-cycle power measurements. One to Four input elements offer Basic Power Accuracy of 0.2% with 2 MHz Bandwidth and 5MS/sec digitizing rates.

WT1600 Digital Power Meter

The High-end WT1600 is designed for a wide range of applications, from energy-saving to large load applications. The WT1600 has a six element input capability to provide maximum flexibility, and Basic Power Accuracy of 0.1% with 1 MHz Bandwidth.

WT1800 High Performance Power Analyzer

The WT1800 Power Analyzer offers maximum flexibility with up to six wattmeter elements, high bandwidths, simultaneous high speed digitizing, and wide voltage and current ranges. Although this model is still available, the newer WT1800E offers higher accuracy.

WT2010/WT2030 Digital Power Meters

The WT2000 digital powermeter series has been designed with emphasis on basic performance (bandwidth, accuracy, response speed, and noise immunity) from the viewpoint of measurement of electrical quantities. The broad range of functions of these power analyzers enable them to be used in various fields of applications.

WT500 - Mid Range

  • Power and Harmonic (THD) Measurements with Independent Range Controls
  • Efficiency measurements of AC/DC or DC/AC Inverters & Motors

 

Analisadores de Potência e Medidores de Potência

A Yokogawa, a maior fabricante mundial de analisadores e medidores de energia e energia, fornece uma ampla gama de analisadores de energia digital para atender a todos os requisitos.

Precision Making

Topo