The IS8000 Integrated software platform enables remote operation, synchronous measurement, data analysis and report output of Yokogawa’s power analyzer, ScopeCorder, oscilloscope and third-party high-speed cameras.
The software can be used for trial for 30 days. After the trial period has expired, functions are restricted. Please purchase the software licenses to lift the restrictions.
All IS8000 models and licenses, except the free trial period, require software activation over the internet before use. If the PC with the IS8000 installed cannot be connected to the network, it is possible to activate the IS8000 via another network-accessible PC.
Functions | Supported devices |
---|---|
Online data acquisition | DL950, WT5000 |
Remote control and setting, acquisition data download | DL350, DL850 series, DL950, DLM3000 series, DLM5000 series, WT5000 (Remote control and setting only) |
Data File Import | DL350, DL850 series, DL950, DL750 (Only WVF file), SL1400 (Only WVF file) , SL1000, WT1800 series, WT3000 series, WT5000, DLM2000 series, DLM3000 series, DLM4000 series, DLM5000 series |
High-speed camera Sync. (FS1 option) |
Supported cameras for online sync.: Photron’s FASTCAM SA-Z, MIni UX*/AX/WX series, NOVA S series, NOVA R2 Supported devices for online sync.: DL950 |
* Pre-trigger recording and multi-trigger recording using the Mini UX series in combination with the FS1 option are not supported.
The writings in red are changes from the previous version.
Ver.23.1.1.0 | ||
Connecting support firmware | DL950 | Ver.1.20 or later |
WT5000 | Ver. 3.31 or later | |
Languages | English / Chinese / Japanese | |
PC requirements | For data acquisition with 10 Gb Ethernet connection; CPU: Desktop PC required Intel Core i7-1165G7 or later Intel CPU 4 cores(8 threads) or more 4.7 GHz or faster Amount of memory: 16 GB or more Amount of SSD: 512 GB or more (M.2 slot is recommended, Sequential read/write 3 GB/s or faster) For data acquisition with 1 Gb Ethernet /USB connection and offline analysis; CPU: Intel Core i5-10210U or later Intel CPU 4 cores(8 threads) or more 4.2 GHz or faster Amount of memory: 8 GB or more Amount of SSD: 256 GB or more (Sequential read/write 400 MB/s or faster) |
|
OS | Windows 11 Pro or Enterprise edition (except EM1 option) Windows 10 64bit Pro or Enterprise edition |
|
Communication interface | USB (USBTMC / VISA), Ethernet (VXI-11 / HiSLIP) | |
Display resolution | 1366×768 dots or higher, 100 % zoom | |
Number of connectable units (SY1 option) | Up to 5 units (Only one unit without SY1 option) (SY1 option is required even if the time synchronisation is not used) |
|
Supported file format | WDF | DL350, DL850 series, DL950, SL1000, DLM2000 series, DLM3000 series, DLM4000 series, DLM5000 series |
CSV (Waveform data) | DL950, DL850 series, DL350, DLM5000/4000/3000/2000 series, Xviewer Application Software and IS8000 *6 | |
CSZ | IS8000 CSV data compressed in ZIP format | |
CSV (Power measurement data)*2 | WT5000 (without multi-unit sync. based on IEEE1588 PTP) WT5000 (with multi-unit sync. based on IEEE1588 PTP.) WT3000 series*1 WT1800 series |
|
WVF | DL750, SL1400 | |
MD4 | IS8000 data files ASAM MDF 4.1 files |
|
mepjt, anpjt | IS8000 Project files | |
Export file formats | ASAM MDF 4.1 files (mf4), ASCII files (csv), CSV files compressed in ZIP format (csz) | |
Online data acquisition (DL950)*7 |
Motion mode | Scope mode (Trigger/ Free-run)*4 The trigger mode cannot be used with multi-unit synchronized DL950s. |
Maximum transfer rate | 10G Ethernet connection: 320MB/s (20MS/s x 8ch, 10MS/s x 16ch) 1G Ethernet / USB connection: 6.4MB/s (200kS/s x 16ch) |
|
Online data acquisition (WT5000)*7 |
Monitoring/DAQ items | Power trend graph and numeric Harmonic bar graph Data-streaming waveform *3 Vector diagram |
Online data acquisition (common)*7 |
Maximum continuous recording time/size | The recording will be kept until free storage space falls below 10%. |
Maximum recording channels | 128 channel | |
Waveform overlays | Aligned by time, absolute time ,head of data, end of data or arbitrary position | |
Automated waveform parameter measurements | Up to 28 parameters (including P-P, Amp, RMS and Freq). | |
Display format | Common | TY-Overview (up to 32 ch for each group, up to 4 group), XY (up to 2 windows for each group), TY-View (up to 4 areas for each group) |
For WT5000 | Power trend graph and numeric display Peak-to-peak compressed waveform (Data update interval: 1s or slower) Bar graph of the amplitude and phase of each harmonic Data streaming waveform display *3 Harmonic list display Matrix display Vector diagram |
|
Automated waveform parameter measurements | Automated measurement of history statistics | Waveform parameters for each waveform in the historical memory and their statistics can be calculated automatically. |
Automated measurement of cycle statistics | Waveform parameters of each period of a cyclic waveform and their statistics can be calculated automatically. | |
Cursor | Vertical, Horizontal, X-Y | |
Annotation function | Comments, acquired data and calculated values can be added on the overview/view, waveform window and X-Y window. | |
Supported devices | Data acquisition | DL950 WT5000(760903 Current Sensor Element supported.10ms update rate supported.) |
Flash ACQ data saving | DL950 | |
Data file import | DL350, DL850 series, DL950, SL1000, WT1800 series, WT3000 series, WT5000, DLM2000 series, DLM3000 series, DLM4000 series, DLM5000 series, DL750 (Only WVF files), SL1400 (Only WVF files) | |
Remote control and setting, acq. data download | DL350, DL850 series, DL950, DLM3000 series, DLM5000 series, WT5000(Remote control and setting only) | |
Screen Capture | Save | Clipboard, ping, jpg, gif |
CSV batch converter | Load | MF4 (MDF4.1), WDF, WVF |
Save | CSV | |
Mathematical data analysis(/MH1) | Number of Math channels | Up to 16 channels |
Operators | +, -, x, /, Phase shift, ABS, SQRT, LOG, EXP, NEG, SIN, COS, TAN, ATAN, PH, DIF, DDF, INTEG, BIN, P2, P3, F1, F2, FV, PWHH, PWHL, PWLH, PWLL, PWXX, DUTYH, DUTYL, FLT1, FLT2, HLBT, MEAN | |
Number of computed points | Up to 12.5 M points | |
Digital filters | Gauss, Sharp, IIR(Butterworth) | |
FFT analysis (/MH1) | Operator | Type: LS, RS, PS, PSD, CS, TF, CH Sub-type: REAL, IMAG, MAG, LOGMAG, PHASE |
Window function | Rect, Hanning, Flat top, Hamming | |
Number of FFT channels | Up to 16 channels independently | |
Number of computed points | Up to 2 M points or up to100 M points can be supported by installing MATLAB Runtime |
|
High-speed camera Sync. (/FS1) | Supported cameras for online sync | Photron’s FASTCAM SA-Z, MIni UX*5/AX/WX series, NOVA S series, NOVA R2 |
Supported video format for online sync | high-speed camera video files(avi) | |
Supported devices for online sync | DL950 | |
Supported video file formats for offline sync | AVI(*.avi), MP4(*.mp4), WMV(*.wmv), AVCHD(*.mts), MOV(*.mov), MPEG2-PS(*.mpg, *.mpeg) |
*1 Harmonic measurement data excluded.
*2 The measurement data of first 128 channels can be imported.
*3 /DS option is required for the WT5000 to be connected.
*4 Trigger DAQ with DL950 external clock input is not supported.
Freerun DAQ with DL950 external clock input, including 16-channel input module or CAN/CANFD/LIN/SENT module, is not supported.
*5 Pre-trigger recording and multi-trigger recording using the Mini UX series in combination with the FS1 option are not supported.
*6 Only CSV files saved with Ver. 22.6.1.0 or later IS8000 can be imported.
*7 Connecting instruments and collecting data with multiple launches of the IS8000 software on the same PC is not covered by the specification.
IS8000 Edition, License and Features
The licenses can either be perpetual or subscription. Please refer to the section 9.6 of the user’s manual.
Please refer to the installation manual.
Version | Date | Description |
---|---|---|
V23.1.1.0
|
Feb 24, 2023
|
New IEC61000 standard (3-3 Ed3.0-amd2) is supported in IS8011/IS8012. "DAQ(WT)", which displays a layout suitable for online DAQ of WT5000, is added to the launcher window. |
V22.6.1.0
|
Dec 28, 2022
|
Added new API function: any waveform file access Improved the performance of analysis functions Enabled importing CSV files saved with DL950, DL850 series, DL350, DLM5000/4000/3000/2000 series, Xviewer Application Software and IS8000 (version 22.6.1.0 or later) |
V22.5.1.0
|
Oct 31, 2022
|
Added new API functions Improved the performance of analysis functions Enabled CSV exports of dual-caputured sub-channel data, FFT analysis data, and sequential historical data Added support for a vector diagram display for offline analysis functions Added support for the latest IEC standard, IEC61000 3-2 Ed5.0-amd1, with IS8011/IS8012 Added support for Windows11 with IS8011/IS8012 (All IS8000 series functions except EM1 option are Windows 11 compliant) FS1 option: The information on camera models that support real-time synchronization has been changed MATLAB Runtime support: By installing MATLAB Runtime, up to 100M of FFT points can be supported |
Previous version
Please read Software Agreement carefully before downloading.
Version | v23.1.1.0 | ||
Release Date | Feb 24, 2023 | ||
File Name | IS8000_23110.zip | 335 MB | |
Type | Software* Registration is required to download. |
Downloading of the software indicates acceptance of the software agreement.
The Yokogawa DL950 ScopeCorder captures and analyzes a wide variety of electrical, physical sensor signals, and serial buses. It offers a unique combination of high sampling rates, for a detailed view and long recording times to monitor trends over time.